  • Page 1 4 Workstation ® User Guide YB-253 Version 3.10 Valid from Firmware version 3.00 0470 XO CARE A/S  Håndværkersvinget 6  DK-2970 Hørsholm  Denmark Tel +45 7020 5511 www.xo-care.com...
  • Page 3: Preface

    Warranty This document describes how XO 4 functions in general. XO warrants that your XO 4 is free from defects in materials and workmanship for a period of 12 months from the date of instal- If you own an XO 4-1 Unit please also see: lation.
  • Page 4: Table Of Contents

    Disinfecting unit water lines with XO Water Clean System (optional) .......
  • Page 5 ® 4 User Guide YB-253 Version 3.10 List of contents 4.5.4 Bien Air MC3 micro motor ............... 13 4.5.5...
  • Page 6 Figure 1: On/Off switch..................................2 Figure 2: Numbering of unit instruments – anterior view ........................3 Figure 3: Multi-functional syringe..............................3 Figure 4: Pedal position and speed reaction ............................3 Figure 5: Placement of instrument bridge............................4 Figure 6: Hand instrument table ...............................4 Figure 7: Seize the headrest ................................5 Figure 8: Locking of headrest ................................5...
  • Page 7 ® 4 User Guide YB-253 Version 3.10 List of tables Table 1: Sounds..................2 Table 2: Error messages .
  • Page 8: Introduction

    ® 4 User Guide YB-253 Version 3.10 Introduction Dear dentist, Congratulations on your new equipment and thank you for choo- sing an XO product. In order for you to obtain maximum benefit from the equipment, please read the delivered guides carefully.
  • Page 9: How To Use Xo 4

    – but only after the pedal on the main XO Foot Control has been de-activated. Note!! An intraoral video camera may be used simultaneously with another selected instrument –...
  • Page 10: Unit Instruments

    3.2.4 Micro motor A maximum of 6 instruments can be attached to the instrument The micro motor is operated as described in XO 4 Quick Guide. bridge. The instruments are numbered 1 – 6, starting from the left. The speed adjusts exponentially in relation to pedal move- ments.
  • Page 11: Intraoral Video Camera

    How to operate auxiliary functions 3.3.1 Patient chair The height and the backrest inclination are adjusted with the joy- stick on XO Foot Control as described in XO 4 Quick Guide. You can choose between 4 pre-configured positions with the XO Joystick: •...
  • Page 12: Patient Positioning

    1 Activate a pre-configured treatment position of your choice 2 Seize the headrest cushion with your right hand 3 Release the lock switch, see Figure 7 4 Now adjust the headrest to support the patient’s neck and head 5 When the backrest passes approx. 45 degrees, lock the...
  • Page 13: Xo Hd Display

    Please note that a bell or other external signalling devices must Please refer to the separate User guide for XO HD Display. be connected to XO 4 before call assistant can be heard. Please agree with your service provider how you would like the call as- 3.3.5...
  • Page 14: Infection Control

    Be careful not to spill the fluid. Any spills must be 4 Switch off the unit and leave the unit instruments in the in- strument holder on the cuspidor. wiped up at once. Then clean the surface with a damp cloth.
  • Page 15: Single Step Water Treatment (Heavy Deposits)

    Otherwise, the suction system may clog up, and break down as a result. If you have chosen to equip XO 4 with XO Suction Disinfection, please proceed to section 4.3.1. If your XO 4 does not have XO Suction Disinfection, the system must be cleaned manually.
  • Page 16: Figure 16 Removal Of Suction Nipple Covers

    Please note that manual cancellation of flushing is not possible. XO Suction Disinfection container (1) must be replaced at spe- cific intervals. When the contents in the container are under a certain level, a “warning” will be activated and the message “CHECK YELLOW BOTTLE”...
  • Page 17: Suction Filters

    Wash the filters in a thermodisinfector (90 Disconnect the suction hoses from the unit and eject the filters Lubricate the O-rings on the filters with XO silicone grease (ref. by pressing the button. no. YR-002) before inserting clean filters (ref. no. MR-075). If air starts to leak from the suction tubes, try to replace the O-rings of the filter cartridge (UC-063 and UC-064).
  • Page 18: Disinfecting Unit And Chair Surfaces

    ® 4 User Guide YB-253 Version 3.10 Disinfecting unit and chair surfa- 4.4.3 Handles Use soap and disinfectants to disinfect surfaces. Please read below. 4.4.1 Cleaning and disinfecting unit surfaces Clean and disinfect the surfaces of the unit using a cloth with Dürr FD-322.
  • Page 19: Chair Upholstery, Standard

    Chair upholstery, XO SCUBA The autoclaving and thermo disinfection processes The XO SCUBA cover can be dried with a dry or damp cloth. If wear down the materials and may cause them to lose their necessary, water based cleaning agents can be used. Vacuum colours or shorten their lifetime.
  • Page 20: Multifunctional Syringe

    Bien Air MC3 micro motor The micro motor cover (1) can easily be removed for autocla- ving at max. 134°. Do not pull the tube! Disinfect the micro motor with Dürr FD-322. Lubricate the o-rings (2) with XO silicone grease (ref. no. YR- 002)
  • Page 21: How To Maintain Your Xo 4

    Approximately 30 days before the next preventive service, a message appears on the unit display when XO 4 is switched on. In case the visit becomes overdue, a warning message will ap- pear on the unit display as well.
  • Page 22: Bien Air Mc3 Micro Motor

    Bien Air MC3 micro motor Figure 29 Removing instrument tube XO recommends annual control and servicing of micro motors When refitting the instrument hoses, please check that instru- and contra-angles. ment tube number and the number marked on the instrument bridge are identical.
  • Page 23: Ultrasonic Scaler

    4 User Guide YB-253 Version 3.10 XO 4 Foot Control If XO Foot Control slides on the floor when activated: Clean rub- ber feet under foot control with benzine. Figure 31 Replacement of bulb in micro motor Please refer to the user guide for the micro motor.
  • Page 24: Error Messages

    ® 4 User Guide YB-253 Version 3.10 Error messages Certain functional errors can be detected by XO 4 and written to the display. Please refer to Table 2 <$elemtextonly<$elem- textonly<$elemtextonly<$elemtextonlyfor interpretation of error codes and remedial action. Error message Interpretation...
  • Page 25: Service Messages

    Service Message Reason for message Remedial action CHECK YELLOW BOTTLE The unit will soon run out of XO Suction Disinfecti- Make sure you have a XO Suction Disinfection container in stock. CHECK WHITE BOTTLE The unit will soon run out of XO Water Clean.
  • Page 26: Useful Consumables, Spare Parts, And Infection Control Parts

    ® 4 User Guide YB-253 Version 3.10 Useful consumables, spare parts, and infection control parts Table 4 provides a list of the most commonly used consumab- les. For a full list, please contact your service provider. Consumables Purpose Ref. no.
  • Page 27: Quality Of Dental Air And Water

    Please note that the quality of dental air and water might be sub- ject to special regulations set out in national laws. The effective filter size on XO 4 is 5 m for air and 50 m for water. In order to ensure proper operational conditions for XO 4 we re- commend the use of (an) oil-free compressor(s) equipped with a dry air aggregate.
  • Page 28: Symbols And Glossary

    The XO Foot Control is placed on the floor and consists of a pe- 3.1.3 trol dal and a joystick as well as 2 switches (only XO 4-2 and XO 4-6) Joystick on XO The joystick on XO Foot Control 3.3.1...
  • Page 29 ® 4 User Guide YB-253 Version 3.10...
  • Page 30 XO is a registered trademark. Printing errors, if any, are subject to reservations, and XO CARE A/S reserves the right at any time to alter specifications without further notice. © 2014 All rights reserved XO CARE.