MODELS:
HCMVQMKN
HCMVQMKLP
WARNING: If the information in this
manual is not followed exactly, a
fire or explosion may result causing
property damage, personal injury,
or loss of life.
FOR YOUR SAFETY: Do not store
or use gasoline or other flammable
vapors and liquids in the vicinity of
this or any other appliance.
INSTALLER: Leave this manual with appliance. CONSUMER: Retain this manual for future reference.
INSTALLER: Leave this manual with appliance. CONSUMER: Retain this manual for future reference.
Grand Canyon Gas Logs burner system is to be installed only in a solid-fuel-burning fireplace with a working flue
constructed of noncombustible material. Solid fuels shall not be burned in a fireplace where the unit is installed.
The installation, including provisions for combustion, ventilation air, and required minimum permanent vent
opening, must conform with the National Fuel Gas Code (ANSI Z223.1/NFPA 54)\ and applicable local building
codes. In Canada, the installation must conform with the Natural Gas and Propane Storage and Handling
Installation Code (CSA-B-149.1). A damper stop clamp is included to maintain the minimum permanent vent
opening and to prevent full closure of the damper blade. The chimney damper must be fixed fully opened
when burning the unit. The burner system is designed to burn with yellow flames; thus, adequate
ventilation is absolutely necessary. If any of these parameters are not met, the warranty could be voided.
Installation & Owner's Manual
For Natural or Propane Gas
WARNING
WARNING
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
– Installation and service must be performed by a
qualified installer, service agency, or the gas suppli
We recommend that our gas hearth products be
installed and serviced by professionals who are
certified in the U.S. by the National Fireplace Institute
(NFI) as NFI Gas Specialists.
Grand Canyon Gas Logs
Grand Canyon Gas Logs
3515 East Atlanta Avenue, Phoenix, Arizona 85040
3515 East Atlanta Avenue, Phoenix, Arizona 85040
602-344-4217 • grandcanyongaslogs.com
602-344-4217 • grandcanyongaslogs.com
Features:
• Standing Pilot System
• Remote Optional
• Wall Switch Optional
Burner capability
• 2 Burner - 2BRNST
• 3 Burner - 3BRNST
• Kiva • Glass
• Jumbo/Jumbo Slim/Jumbo ST
er.
08_2022_V1
01_2022_V1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HCMVQMKN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Grand Canyon Gas Logs HCMVQMKN

  • Page 1 INSTALLER: Leave this manual with appliance. CONSUMER: Retain this manual for future reference. Grand Canyon Gas Logs burner system is to be installed only in a solid-fuel-burning fireplace with a working flue constructed of noncombustible material. Solid fuels shall not be burned in a fireplace where the unit is installed.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Specifications ................1 Important Information ..............2 Bill of Materials - Parts List ............3 Wire Diagram - Millivolt ...............4 Pre-Installation................5 Installation ..................6 L.P. Gas Applications ..............8 Procedure for Lighting or Relighting ...........9 Service Instructions ..............10 Troubleshooting ................12 Warranty ...................13 NOTE: Changes may change without notice, Changes will be shown on updated versions.
  • Page 3: Important Information

    IMPORTANT INFORMATION CHECK TO BE SURE THAT THE PROPER FUEL GAS IS BEING USED WITH THIS CONTROL SYSTEM. The installation, including provisions for combustion and ventilation air, must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code (ANSI Z223.1/NFPA 54).
  • Page 4 BILL OF MATERIALS Model # Description 700-506 Millivolt Valve MV-PILOT-18 18" Millivolt Pilot Assembly (NG version) MV-PILOT-18P 18" Millivolt Pilot Assembly (LP version) US-4-8 1/2" x 1/2" Swivel Nut Union 46-88 Straight Connector 1/2" OD x 1/2" FIB Heat Shield - HC Millivolt Heat Shield Reducer - 3/2 3/4"...
  • Page 5: Wire Diagram - Millivolt

    WIRE DIAGRAM - MILLIVOLT GrandCanyonGasLogs.com customerservice@grandcanyongaslogs.com...
  • Page 6 STEP BY STEP PRE-INSTALLATION This Millivolt Control must be installed by a qualified professional service technician. Instructions must be followed carefully when installing to ensure proper performance. These instructions must be used as a supplement to the instructions supplied with the Grand Canyon Gas Logs burner system.
  • Page 7: Pre-Installation

    PRE-INSTALLATION Leave the first two threads clean. 8. DO NOT insert any object other than suitable pipe or tubing in the inlet or outlet of this con- Never use compound on female threads as it trol. Internal damage may occur and result in a might be pushed into the control body.
  • Page 8: Installation

    INSTALLATION Locate the silver gas control (700-506) as well as the 2 48-88 (1/2” MIP x 1⁄2” Flare Straight), 2 B5309-8 (90 Degree Elbow 1⁄2”) and the 2 113BS-D (Schedule 40 1⁄2” MIP Closed) Fittings. Review Fig. 1. Using proper pipe thread compound on all non-flare connections, install the 48-88 into the “IN”...
  • Page 9: L.p. Gas Applications

    INSTALLATION Coil the pilot tubing using proper bending techniques and insert the ¼" flare end into the “PILOT” connec- tion on the valve. Wrench until tight. Fig. 5. FIG 5 Coil the Thermopile lead and connect the terminals to the valve. Color sequence does not matter, connect (1) lead to the TP and (1) lead to the TH/TP.
  • Page 10 FOR YOUR SAFETY - LIGHTING INSTRUCTIONS “WARNING – If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.” A. This appliance has a pilot which must be 4.
  • Page 11: Procedure For Lighting Or Relighting

    PROCEDURE FOR LIGHTING SERVICE INSTRUCTIONS OR RELIGHTING CAUTION: If control has been exposed to water in any way, it must be replaced. If gas valve fails to shut off, do not turn off electrical power. Turn off gas supply allowing fan or circulating pump (if so equipped) to continue run- ning until system has cooled.
  • Page 12: Service Instructions

    SERVICE INSTRUCTIONS PILOT BURNER ADJUSTMENT REGULATOR REPLACEMENT 1. Remove pilot adjustment cap. If it is necessary to change to another gas then the valve operator will need to be changed. 2. Adjust pilot key to provide properly sized flame on the thermopile.
  • Page 13: Troubleshooting

    TROUBLESHOOTING PROBLEM CAUSE SOLUTION 1. Pilot will not light a Obstruction in pilot gas supply or a. Clear out obstruction. pilot gas-supply line is kinked Replace pilot gas-supply line if b. Inadequate gas pressure kinked c. Air in line b. Have gas pressure checked by installer or gas supplier c.
  • Page 14: Warranty

    WARRANTY Burner: Electrical and Valves: Grand Canyon Gas Logs burners carry a life time warranty against Grand Canyon Gas Logs valves, remotes & receivers carry a (2) manufacture defects or breakage as long as the appliance is in- year warranty against breakage or defects from date of purchase, stalled inside and by a professional installer.
  • Page 15 DO NOT RETURN TO STORE! STOP CALL US FIRST For immediate help with installation, product information or if your product arrives damaged, please call our toll free number at: 1-602-344-4217 (Monday - Friday, 8:00AM - 5:00PM, AZ Mountain Time) or email us at: customerservice@grandcanyongaslogs.com OUR STAFF IS READY TO PROVIDE ASSISTANCE GrandCanyonGasLogs.com...
  • Page 16 RPG Brands family of companies Copyright © 2022 RPG Brands (Grand Canyon Gas Logs). All rights reserved. Products and specifications subject to change without notice. The product images shown are for illustration purposes only and may not be an exact representation of the product.