Cleaning; Safety Inspection; Disposal - ebm-papst K3G280-RR10-P1 Operating Instructions Manual

Table of Contents

Advertisement

K3G280-RR10-P1
Motor/electronics
Deficient cooling
overtemperature
Thermal overload
protector activated
Ambient temperature
too high
Impermissible point of
operation
In the event of further malfunctions, contact ebm-papst.

5.1 Cleaning

To ensure a long service life, check the fans regularly for proper
operation and soiling. The frequency of checking is to be adapted
accordingly depending on the degree of soiling.
; Dirt deposits on the motor housing can cause overheating of the motor.
; Soiling of the impeller can cause vibration that will shorten the service
life of the fan.
; Severe vibration can destroy the fan.
; In such cases, switch off the fan immediately and clean it.
; The preferred method of cleaning is dry cleaning, e.g. using
compressed air.
; Do not use aggressive cleaning agents!
NOTE
Damage to the device during cleaning
Malfunction possible
→ Do not clean the device using a high-pressure cleaner.# Do
not use acid, alkali or solvent-based cleaning agents.
→ Do not use any pointed or sharp-edged objects for
cleaning.
; Completely remove any cleaning agents used.
; If severe corrosion is visible on load-bearing or rotating parts, switch
off the device immediately and replace it.
; Repair of load-bearing or rotating parts is not permitted!
; Operate the fan for 2 hours at maximum speed so that any water that
has ingressed can evaporate.
; If cleaning does not eliminate vibrations, the fan may need to be
rebalanced. To have it rebalanced, contact ebm-papst.
; The fan is equipped with maintenance-free ball bearings. The lifetime
lubrication of the ball bearings is designed for a service life of 40,000
hours.
; If bearing replacement is necessary after that period, contact ebm-
papst.
; Adapt the maintenance intervals to the actual level of dust exposure.
Item no. 56771-5-9970 · ENU · Change 246756 · Approved 2022-01-13 · Page 11 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Improve cooling. Let

5.2 Safety inspection

the device cool down.
What to check
To reset the error
Contact
message, switch off
protection
the line voltage for at
cover for
least 25 s and then
intactness or
switch it on again.
damage
Allow motor to cool
Device for
off, locate and rectify
damage to
cause of error,
blades and
release restart lockout
housing
if necessary
Fastening the
Reduce the ambient
cables
temperature.
Fastening the
Reset by reducing
protective earth
control input to 0.
terminal
Correct the operating
Insulation of
point. Let the device
cables for
cool down.
damage
Impeller for
wear/deposits/
corrosion and
damage
Condensation
drainage holes
for clogging,
where necessary
Abnormal
bearing noise
Vibration test

5.3 Disposal

For ebm-papst, environmental protection and resource preservation are
top priority corporate goals.
ebm-papst operates an environmental management system which is
certified in accordance with ISO 14001 and rigorously implemented
around the world on the basis of German standards.
Right from the development stage, ecological design, technical safety
and health protection are fixed criteria.
The following section contains recommendations for ecological disposal
of the product and its components.
5.3.1 Country-specific legal requirements
How to check
How often
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
acoustic
At least every
6 months
Vibration tester,
Recommended
start-up or
every 6 months
deceleration
measurement
NOTE
Country-specific legal requirements
Always observe the applicable country-specific legal
regulations with regard to the disposal of products or waste
occurring in the various phases of the life cycle. The
corresponding disposal standards are also to be heeded.
What action?
Repair or
replacement of
device
Replacement of
device
Fasten
Fasten
Replace cables
Clean impeller
or replace device
Open holes
Replace device
Clean impeller
or replace device