  • Page 1 User Manual DSK series Scale...
  • Page 3: Safety Requirements

    Thank you for purchasing counting electronic scale, in order to effectively help you to use our products correctly, please read the manual carefully, which will help you to operate and extend the life of the products, and reduce inconvenience. 1. Safety requirements: 1.
  • Page 4: Specification

    4. Specification Maximum capacity 3000 6000 15000 30000 (g) Minimum capacity (g) verification scale intervale(g) Division (g) Minimum sample weight(g) Minimum single weight 0.15 0.75 (g) Minimum sampling quantity(PCS) ±0.2 ±0.4 ±1.0 ±2.0 repeatability(g) ±0.2 ±0.4 ±1.0 ±2.0 linearity(g) Display 3*LCD backlight display Keys 20 touch keys...
  • Page 5: Keyboard Functions

    6. Display and key panel description 7. Keyboard Functions 7.1. Keys 1. [PCS SET]: place a sample on the scale plate, input the number of samples through the digit keyboard [also can input the number of completed samples in advance], press [PCS SET] the ‘UNIT WEIGHT’ window display ‘SnnP’...
  • Page 6: Menu Settings

    5. [M+]: used for the accumulative number of counting. Under the accumulative state, the ‘M+’ is lit up, and the accumulative number is not more than 999999 PCS, and the accumulative number is not more than 99 times. 6. [MC]: clear cumulative total, cumulative symbol off. 7.
  • Page 7 8.2. Description of submenu Settings WEIGHT UNIT WEIGHT WEIGHT UNIT WEIGHT window window window window FUN01-DIV FUN02-PNT Indexing value Decimal position setting setting WEIGHT UNIT WEIGHT WEIGHT UNIT WEIGHT window window window window FUN03-CAP Full range setting Enter the maximum weight directly FUN04-CAL through the numeric key.
  • Page 8 Direct input needs to load the value of calibration weight,Load the FUN06-USR calibration weight,press User manual [ALARM],Exit after completion of calibration calibration. WEIGHT UNIT WEIGHT WEIGHT UNIT WEIGHT window window window window FUN08-BUD FUN07-LIT Baud rate Setting 1200 Backlight mode (this function is 2400 setting...
  • Page 9: Trouble Removal

    11. Trouble Removal The following table shows the possible causes and solutions of common problems and failures. It is for reference only. If you still have any questions, please contact the authorized dealer. Symptoms Possible reasons Check solution for reference Can not turn on No power connection, no battery Check that the power connection and...
  • Page 10 01/16062021...