NORMAL OPERATING MODE

When switching the machine on, the message "Starting"
is displayed for a few seconds, after which the machine
goes into normal operating mode.
The displayed massages indicating the operation being
carried out are fixed, while the instructions requiring an
action from the user are blinking; the messages include
the following:
DISPLAY
Select drink
Press key
Vending machine
out of service
Selected drink
essed
Wait please
Drink ready
Take drink

FILLER MENU

When pressing once the programming button located on
the coin mechanism compartment, the machine goes into
"Filler menu" mode.
The first option of the "filler" menu is displayed, allowing
the following functions:

"Statistics"

Data reading
"Prices"
Changing the price for one
selection
"Tube control"
Manual refilling and release
of change-giver tubes
"Display Temperat." Displays the boiler
temperature
"Test"
Complete selection
Dispensing water only
Dispensing powder only
Dispensing without accessories
Dispensing accessories only
"GSM"
Reset pre-alarm counters
"EVADTS"
Connection
© by NECTA VENDING SOLUTIONS SpA
FUNCTION
Machine ready
Machine out
of service
Processing the proc-
drink
Dispensing ended
correctly
STATISTICS
Data on the machine operations is stored in both general
counters and relative counters, which can be reset without
losing total data.
PRINT
Connect an RS232 serial printer having a Baud rate of
9600, 8 data bit, no parity, 1 stop bit to the serial port
located on the push button board to print all of the
statistics, and namely:
Total
1 - counter by single selection;
2 - counter by time bands;
3 - discount counter;
4 - failure counter;
5 - coin mechanism data.
Relative
1 - counter by single selection;
2 - counter by time bands;
3 - discount counter;
4 - failure counter;
5 - coin mechanism data.
The printout will also contain the machine code, the date
and the software version.
To connect the printer, do as follows:
- press the confirm print button " ", displaying the mes-
sage "Confirm?";
- connect the printer before confirming;
- press the confirm button " " again to start printing.
DISPLAY
When pressing the confirm button " " the data described
in the paragraph "Printing the statistics" is sequentially
displayed.
DELETE STATISTICS
Statistics can be reset for relative counters globally (all
types of data) or selectively for:
- selections
- discount / overprice
- failures
- coin mechanism data
Press the confirm button " ", and the message "Confirm?"
starts blinking.
Press the confirm button " ", the message "Working" is
displayed for a few seconds and all statistics are reset.