ScienceDesk
SDA Series
SDP Series
SDH Series
SDR Series
User Guide
Original Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ScienceDesk SDA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for THORLABS ScienceDesk SDA Series

  • Page 1 ScienceDesk SDA Series SDP Series SDH Series SDR Series User Guide Original Instructions...
  • Page 2: Table Of Contents

    Contents Chapter 1 Introduction ............................3 1.1 General Description ............................3 1.2 Accessories ................................3 Chapter 2 Safety ..............................4 2.1 Safety Information ..............................4 2.2 General Warnings ..............................4 Chapter 3 Basic Installation ..........................5 3.1 Installing the Frame ............................5 3.2 Fitting the Casters ..............................5 3.3 Installing the Breadboard ...........................6 3.3.1 Rigid Mounts ..................................6 3.3.2 Passive Mounts ..................................7 3.3.3 Active System ..................................10...
  • Page 3: Chapter 1 Introduction

    Throughout this handbook, all examples refer to a standard height desk. A standing height option is also available and all instructions apply eually to these variants. 1.2 Accessories Thorlabs provide a range of accessories to assist in the mounting of ancilliary components, please see www.thorlabs.com for more details.
  • Page 4: Chapter 2 Safety

    Chapter 2 Chapter 2 Safety 2.1 Safety Information For the continuing safety of the operators of this equipment, and the protection of the equipment itself, the operator should take note of the Warnings, Cautions and Notes throughout this handbook and, where visible, on the product itself. The following safety symbols may be used throughout the handbook and on the equipment itself.
  • Page 5: Chapter 3 Basic Installation

    During item (2), safe lifting precautions must be observed. In particular, do not lift more than 25 kg (55 lb) per person. Use more people or lifting apparatus as necessary. Frame weights are detailed on www.thorlabs.com. 2) Install the frame in the location in which it is to be used.
  • Page 6: Installing The Breadboard

    Chapter 3 3.3 Installing the Breadboard 3.3.1 Rigid Mounts The breadboard rests on rubber pads, three in each corner of the frame. Levelling of the work surface is acheived by adjusting the feet. A Installation 1) Ensure the frame is correctly sited and level – see Section 3.1. Note The desk is normally supplied with the anti-vibration mounts and breadboard already fitted.
  • Page 7: Passive Mounts

    ScienceDesk Workstation 3.3.2 Passive Mounts Equipment Required: Levelling device (e.g., bubble level) Foot pump (automobile tire type) A Installation 1) Ensure the frame is level – see Section 3.1. Note The desk is normally supplied with the anti-vibration mounts and breadboard already fitted. Steps (2) to (6) are applicable only if the unit has been air-freighted or shipped to its destination.
  • Page 8 Chapter 3 5) Connect the foot pump to the mount on one of the legs and inflate to about 40 p.s.i. – see Fig. 3.5. 6) Inflate the leg diagonally opposite to 40 p.s.i. 7) Repeat steps 5) and 6) for the two remaining legs. Caution During item (8), the total load including the breadboard must not exceed the following figures: Standard mounts –...
  • Page 9 ScienceDesk Workstation light load heavy load 12mm 12mm correctly inflated over inflated under inflated Caution If left unchecked, the mounts will deflate over time. To maintain correct inflation, check the gap every two weeks and re-inflate the system as necessary. Fig.
  • Page 10: Active System

    Chapter 3 3.3.3 Active System Equipment Required: Air compressor or continuous air supply Parts supplied: Air hose A Installation 1) Ensure the frame is level – see Section 3.1. 2) Fit the four 1/4-20 (M6) socket cap screws to the outermost holes on the underside of the breadboard, one in each corner. 3) Fit the lifting handles supplied to the breadboard as shown in Section 3.3.1.
  • Page 11 ScienceDesk Workstation Air inlet on inside of upper rear rail Fig. 3.8 Location of height adjusters Caution During item (13), the total load including the breadboard must not exceed 700kg (1545 lb). 13) Populate the breadboard. Adjust the three height adjusters by equal amounts until the gap between the underside of the breadboard and the mounting plate is about 0.27”...
  • Page 12: Accessories

    Thirty-two accessory mounting points along the upper rails provide numerous configuration options to help simplify the customization of your workstation. A small, portable compressor and an air regulator are also available for use with active isolation systems. Please see www.thorlabs.com for full details. HA0200T Rev 11 Jun 2022...
  • Page 13: Chapter 4 Considerations For Ergonomic Layout

    ScienceDesk Workstation Chapter 4 Considerations For Ergonomic Layout Note The ScienceDesk and its accessories have been designed to provide maximum adaptability, thereby ensuring the most ergonomically favorable work environment for the operator. When setting up the final layout of the workstation, consideration should be given to the position of the operator, the positioning of the various pieces of equipment in relation to the operator, and the duration of use for each unit.
  • Page 14 Chapter 4 Once the user is seated, their seating height and footrest (if used) should be adjusted so the interface with the ScienceDesk is comfortable – See Fig. 4.1 for guidance on preferred workspaces. Note For simplicity, only one body size is shown and adaptations for other body sizes will be necessary. It is advisable to leave legroom, which is free from obstructions/ bump hazards, under the desk.
  • Page 15: Chapter 5 Packing List

    ScienceDesk Workstation Chapter 5 Packing List Manual Fitting 6 x 20 Soc Cap Screw HA0200T CE0225 DB0063 Qty 8 Lifting Handles Black Tube 1/4” x 3/4” Soc Cap Screw CG0196 Qty 4 CE0095 7m DB0257 Qty 8 1/4” x 1/2” Screw M6 Washer M6 x 12 Soc Cap Screw DB0254 Qty 4...
  • Page 16: Chapter 6 Declaration Of Conformity

    Chapter 6 Chapter 6 Declaration of Conformity HA0200T Rev 11 Jun 2022...
  • Page 17 ScienceDesk Workstation Thorlabs Worldwide Contacts For technical support or sales inquiries, please visit us at www.thorlabs.com/contact for our most up-to-date contact information. USA, Canada, and South America UK and Ireland Thorlabs, Inc. Thorlabs Ltd. sales@thorlabs.com sales@uk.thorlabs.com techsupport@thorlabs.com techsupport.uk@thorlabs.com Europe Scandinavia...
  • Page 18 www.thorlabs.com...