Page 1
Instruction Manual HB-TP180/200 Checking Facility for Temperature Control Units...
Page 2
Contents 2018-11 O8354-EN Instr ucti on Manual HB-TP180/200 Chec ki ng F acility for T emper ature C ontrol Units HB-THERM AG Spinnereistrasse 10 (WU 3) Postfach 9006 St. Gallen Switzerland www.hb-therm.ch (Typenschild) E-Mail info@hb-therm.ch Phone +41 71 243 6-530...
HB-TP180/200 Checking Facility for Temperature Control Units Contents Index ....................5 General ..................6 Information about this manual ........6 Explanation of symbols ..........7 Limitation of liability ............. 8 Copyright ..............8 Warranty terms ............9 Customer Service ............9 Safety ..................
Page 4
HB-TP180/200 Checking Facility for Temperature Control Units Contents 7.2.1 Flow chart up to SW51-2_1825 ....32 7.2.2 Flow chart from SW51-2_1844 ....33 7.2.3 Testing ............34 7.2.4 Settings ............35 7.2.5 Calibrating the unit ........36 7.2.6 Save protocol to a USB data carrier ..36 Manual test sequence ..........
HB-TP180/200 Checking Facility for Temperature Control Units Index Index Operating fluids ..........21 Overview ............23 CE Declaration of Conformity ......17 Cleaning .............. 45 Packing .............. 27 Connection Personnel ..........12, 44, 46 Main and return line ........20 Preparing the test ..........
HB-TP180/200 Checking Facility for Temperature Control Units General 1 General 1.1 Information about this manual After reading this manual, the operator will be able to safely and efficiently handle the checking facility for temperature control units. The manual is an integral part of the checking facility for...
HB-TP180/200 Checking Facility for Temperature Control Units General 1.2 Explanation of symbols Warnings Warnings are identified by symbols. These warnings are introduced by signal words, which express the severity of a danger. Adhere to these warnings and act cautiously in order to avoid accidents, personal injuries and damage to property.
HB-TP180/200 Checking Facility for Temperature Control Units General 1.3 Limitation of liability All information and notes in this Manual were compiled under due consideration of valid standards and regulations, the present status of technology and our years of knowledge and experience.
HB-TP180/200 Checking Facility for Temperature Control Units General 1.5 Warranty terms The warranty terms are provided in the manufacturer's terms and conditions. 1.6 Customer Service For technical information, please contact the HB-Therm representatives or our customer service department www.hb-therm.ch.
HB-TP180/200 Checking Facility for Temperature Control Units Safety 2 Safety This paragraph provides an overview of all important safety aspects for optimal protection of personnel as well as safe and trouble-free operation. Disregarding this Manual and safety regulations specified therein may result in considerable danger.
HB-TP180/200 Checking Facility for Temperature Control Units Safety 2.2 Customer’s responsibility The device is implemented commercially. Thus the owner of the device is subject to legal industrial safety obligations. In addition to the safety instructions in this Manual, the safety,...
HB-TP180/200 Checking Facility for Temperature Control Units Safety 2.3 Personnel requirements 2.3.1 Qualifications WARNING! Danger of injury if insufficiently qualified! Improper operation can lead to serious personal injuries or property damage. Therefore: – Have all activities performed only by qualified personnel.
HB-TP180/200 Checking Facility for Temperature Control Units Safety 2.3.2 Unauthorized persons WARNING! Danger for unauthorized persons! Unauthorized persons not meeting the requirements outlined here are not aware of the dangers in the work area. Therefore: – Keep unauthorized persons away from the work area.
HB-TP180/200 Checking Facility for Temperature Control Units Safety 2.4 Personal protective equipment When working, it may be necessary to wear personal protective equipment in order to minimise dangers to health. During work, always wear the protective equipment necessary for the particular work.
HB-TP180/200 Checking Facility for Temperature Control Units Safety 2.5 Specific dangers The following section lists the residual risks that have been determined by the risk assessment. Heed the safety instructions listed here, and the warnings in subsequent chapters of this Manual, to reduce health hazards and to avoid dangerous situations.
HB-TP180/200 Checking Facility for Temperature Control Units Safety 2.6 Stickers and decals The following symbols and information decals can be found in the danger zone. They refer to the immediate vicinity around their location. WARNING! Danger of injury because of illegible symbols! Over the course of time stickers and decals may become dirty or illegible for any other reason.
HB-TP180/200 Checking Facility for Temperature Control Units Safety 2.7 CE Declaration of Conformity for Machinery (CE-Directive 2006/42/EG, Annex II 1. A.) Product Checking facility for temperature control units Unit types HB-TP180 HB-TP200 HB-THERM AG Manufacturer Address Spinnereistrasse 10 (WU 3) Postfach 9006 St.
HB-TP180/200 Checking Facility for Temperature Control Units Technical data 3 Technical data 3.1 General Information Fig. 1: Dimensions HB-TP180/200-12 O8354-EN 2018-11...
Page 19
HB-TP180/200 Checking Facility for Temperature Control Units Technical data Fig. 2: Dimensions HB-TP180-45 Value Unit Max. weight HB-TP180 HB-TP200 O8354-EN 2018-11...
HB-TP180/200 Checking Facility for Temperature Control Units Technical data 3.2 Emissions Value Unit Surface temperature >75 °C 3.3 Operating conditions Value Unit Environment Temperature range 5–40 °C Relative humidity* 35–85 % RH * non-condensing 3.4 Connection values Value Unit Connection main and return line Thread HB-TP180-45 R 1¼...
HB-TP180/200 Checking Facility for Temperature Control Units Technical data 3.5 Operating fluids Depending on the version, the following materials are used: Copper NBR (Nitrile rubber) ® Brass FPM (Viton Bronze PTFE (Teflon) ...
HB-TP180/200 Checking Facility for Temperature Control Units Technical data Heat transfer oil Suitable heat transfer oils must be used for operation with oil. (HB-TP200) WARNING! Danger may result if unsuitable heat transfer oils are used Using unsuitable oil poses the risks of cracking, overheating and fire.
HB-TP180/200 Checking Facility for Temperature Control Units Structure and function 4 Structure and function 4.1 Overview Fig. 3: Overview Connection for temperature measurement Pt 100 and thermocouple Type J Pressure gauge main line Pressure gauge return line Central lock Shut-off valve 4.2 Functional principle...
HB-TP180/200 Checking Facility for Temperature Control Units Structure and function 4.3 Connections The connections are marked as follows: Inlet main line Outlet return line Fig. 4: Connections HB-TP180/200-12 Fig. 5: Connections HB-TP180-45 O8354-EN 2018-11...
HB-TP180/200 Checking Facility for Temperature Control Units Structure and function 4.4 Work and danger zones Working areas The primary working area is located at the front of the temperature control unit or the Panel-5 control module. The secondary working area is located at the rear of the temperature control unit.
HB-TP180/200 Checking Facility for Temperature Control Units Transport, packing and storage 5 Transport, packing and storage 5.1 Safety notes for transport Improper transport ATTENTION! Damage due to improper transport! Improper transport can result in considerable material damage. Therefore: – Only use original or equivalent packaging.
HB-TP180/200 Checking Facility for Temperature Control Units Transport, packing and storage 5.3 Packing The checking facility is packed in a carrying case appropriate to the expected transport conditions. The packaging should protect the individual components from transport damage, corrosion and other damage. Therefore, do not destroy the packaging.
HB-TP180/200 Checking Facility for Temperature Control Units Transport, packing and storage 5.4 Symbols on the packing Protect against wetness Protect packages against wetness and keep dry. Fragile Identifies packages with fragile or sensitive content. Handle package with care, do not drop and do not subject to shock loads.
HB-TP180/200 Checking Facility for Temperature Control Units Installation 6 Installation 6.1 Safety Personnel The installation and commissioning must only be carried out by qualified personnel. Work on the electrical system must only be carried out by certified electricians.
HB-TP180/200 Checking Facility for Temperature Control Units Installation 6.2 Installation work Before checking the temperature control unit, prepare the temperature control unit as follows: Connect cooling water inlet and NOTE! outlet In order to optimally utilize the cooling capacity of...
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7 Testing 7.1 Test principle Ohms / °C Main line Pt 100 Reference Temperature Control Units Fe-CuNi External 12 Lmin @ 1 bar Return line HB-TP180/200 Fig. 7: Test principle 7.2 Automatic Thermo-5 test sequence Requirement For the automatic test sequence, at least software version >...
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7.2.1 Flow chart up to SW51-2_1825 Start quality check Testing temperature 3 / 4 (option) Basic temperature control (40 °C) Start-up to testing temperature Testing external sensor (if ZE is Recording of reference...
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7.2.2 Flow chart from SW51-2_1844 Nominal value 40 °C Start quality check Test cooling time Unit ON nominal value 40 °C Recording of flow rate values Testing external sensor Pt 100 (if ZE is available)
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7.2.3 Testing Proceed as follows to start the test sequence automatically: Open the shut-off valve (move the lever upward). Open the Service \ TP test menu page. parameter to „ON“. Set the Quality Test ...
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7.2.4 Settings Testing temperatures If additional testing temperatures must be run, this can be conducted using Testing temperature Testing temperature Proceed as follows in order to set the testing temperatures: Open the Service \ TP-test menu page.
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7.2.5 Calibrating the unit With the automatic testing, the important measured values, of the temperature control unit, can be adjusted in comparison with the entered values at the end of the test. The measured values are: ...
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7.3 Manual test sequence 7.3.1 Preparing the test The TPC calculation program is needed for the recording of actual data, analysis and creation of a test protocol. The software is available under http://hb.click/SO_TPC.
Page 38
HB-TP180/200 Checking Facility for Temperature Control Units Testing Connect the reference measuring device with the instrument leads to the Reference Pt 100 port. Set the following parameters as indicated. only for Thermo-5: Open the Setting \ Controller menu page.
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7.3.2 Testing Proceed as follows to start the test sequence: Open the shut-off valve (move the lever upward). Switch the unit on by pressing the key. Open the Nominal values menu page.
Page 40
HB-TP180/200 Checking Facility for Temperature Control Units Testing NOTICE! Thermo-5: With a flow rate = 0,0 L/min, the “Flow rate zero” alarm is triggered after approximately 30 sec. Series 4: With a flow rate = 0,0 L/min, the “Flow rate zero” alarm is triggered after approximately 4 min.
Page 41
Pressure return line (HB-TP180/200) System pressure actual value (Displayed on unit) Fig. 22: Table external pressure Pressure gauge (rear of unit) only for ZU (Thermo-5): Pressure main line (HB-TP180/200) 21. Carry out safety test ( page 42). O8354-EN 2018-11...
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7.4 Safety test Remove unit covers as described in the Operating Instructions (Maintenance Chapter). Only on water appliances: Proceed as follows to test the pressure relief valve: Switch on the unit by pressing the key.
HB-TP180/200 Checking Facility for Temperature Control Units Testing 7.5 Complete the test Set the following parameters back to the value read before the test. only for Thermo-5: Optionally, the parameter file saved before the test can be downloaded from the USB data carrier (...
HB-TP180/200 Checking Facility for Temperature Control Units Maintenance 8 Maintenance 8.1 Safety Personnel Maintenance tasks described here can be performed by the operator, unless otherwise indicated. Some maintenance tasks must only be carried out by qualified personnel or by the manufacturer exclusively. If this is required, it is pointed out separately in the description of the respective faults.
HB-TP180/200 Checking Facility for Temperature Control Units Maintenance 8.2 Maintenance schedule The next paragraphs describe the maintenance work necessary for optimum and trouble-free operation. If, during regular checks, increased wear is detected, then the required maintenance intervals are to be reduced corresponding to the actual signs of wear.
HB-TP180/200 Checking Facility for Temperature Control Units Disposal 9 Disposal 9.1 Safety Personnel Disposal must only be carried out by qualified personnel. 9.2 Disposal of materials Once the end of the useful life has been reached, the unit must be disposed of in an environmentally compatible manner.
Therefore: – Use only the manufacturer’s genuine replacement parts. For repairs, the checking facility must be shipped to HB-Therm Switzerland( www.hb-therm.ch). Following a repair, HB-Therm will check and, if required, adjust the checking facility. O8354-EN 2018-11...
HB-TP180/200 Checking Facility for Temperature Control Units Technical information 11 Technical information 11.1 Item location X 114 X 113 HB-TP180/200-12 HB-TP180-45 11.2 Legend Designation only with version Main line Return line Main line pressure gauge Return line pressure gauge Shut-off valve...
Need help?
Do you have a question about the HB-TP180 and is the answer not in the manual?
Questions and answers