Download Print this page

Sealey SMC01.V3 Instructions page 3

Compact auto maintenance battery charger 3-cycle 12v

Advertisement

4.3.2.
connect the negative (-) black clamp to the negative (-) battery post and connect the positive (+) red clamp to the positive (+) battery
post or vehicle chassis.
4.4.
BAtterY not connected to A VeHicle.
4.4.1.
connect the (+) red clamp to the positive (+) battery post and connect the (-) black clamp to the negative (-) battery post.
4.5.
PermAnent connection to VeHicle usinG eYelet leAd.
4.5.1.
connect the eyelet on the red (+) wire to the positive (+) battery terminal and connect the eyelet on the black (-) wire to the negative (-)
battery terminal.
Bs 1363/A
uK 3 pin plug
A
5. operation
note:connect the charger to the battery as instructed in section 3 before connecting to mains power supply.
5.1.
connect cHArGer to mAins PoWer suPPlY.
5.1.1.
insert the three pin plug on the mains lead into an isolated mains power supply.
5.1.2.
switch on the mains power supply and the "PoWer" led will illuminate.
5.1.3.
depending upon battery status, either the "cHArGinG" led or the "full" led will also illuminate.
5.1.4.
if "cHArGinG"; monitoring only required.
5.1.5.
if "full" and maintainer mode is not required, switch off the mains power supply, disconnect, clean and store indoors.
fig.2
1
2
absorption
bulk
3 cYcle cHArGinG GrAPH
5.2.
3 - stAGe cHArGinG (fig. 2)
5.2.1.
stage 1 Bulk/rapid start charge (20%-70% charge) the charger delivers maximum charging amperage to re-energise any 12 Volt
battery, digital sensors automatically moves into stage 2 of the process.
5.2.2.
stage 2 Absorption charge (70%-90% charge) maintains the charge at a safe voltage, which remains constant while the current
requirement diminishes.
5.2.3.
stage 3 maintenance (90%-100% charge) Voltage is automatically maintained with pulsing low input current. occasional monitoring
only required.
6. maintenance
6.1.
This charger requires no specific maintenance other than cleaning which should be done with a dry cloth or a tissue. Do not use any
solvents or cleaning agents on the casing.
6.2.
ensure that the charger is unplugged from the mains before installing or performing any maintenance.