Piper RIP-1 Installation And Operating Manual

Piper RIP-1 Installation And Operating Manual

Roll-in proofer

Advertisement

ROLL-IN PROOFER
RIP-1, RIP-2
Installation and Operating Manual
For service information call 800-544-3057
Please have the following information available
before calling. Information can be found on the
identification/certification tag:
•Model Number
•Serial Number
•Date of Purchase
•Part Description and number as shown in parts list
IMPORTANT INFORMATION
READ BEFORE USE
This manual contains important safety information concerning the maintenance, use and operation of this product.
Failure to follow these instructions could result in damaging equipment, voiding the warranty, serious injury or even death.
Piper Products, Inc
300 South 84th Avenue
Wausau, WI 54401
Phone: 715-842-2724 . FAX: 715-842-3125

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RIP-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Piper RIP-1

  • Page 1 ROLL-IN PROOFER RIP-1, RIP-2 Installation and Operating Manual For service information call 800-544-3057 Please have the following information available before calling. Information can be found on the identification/certification tag: •Model Number •Serial Number •Date of Purchase •Part Description and number as shown in parts list...
  • Page 3: Table Of Contents

    REPLACEMENT PARTS - FRONT REPLACEMENT PARTS - SIDE REPLACEMENT PARTS - REAR REPLACEMENT PARTS - FAN ASSEMBLY REPLACEMENT PARTS - RIP-1 AUTO HUMIDITY REPLACEMENT PARTS - RIP-1 AUTO HUMIDITY WIRING DIAGRAM - RIP-1 WITH AUTOFILL WIRING DIAGRAM - RIP-2 WITH AUTOFILL...
  • Page 4: Introduction

    Congratulations! You have just purchased one of the finest pieces of equipment on the market today. Before installing or operating your new Piper equipment, you should read through this manual. This manual should be retained for further reference as it contains installation and operating instructions, service tips, part lists and warranty information.
  • Page 5: Safety Precautions

    TO REMOVE THE EQUIPMENT FROM THE SKID 1. Tilt unit backward at a 45˚ angle. 2. Push down on front of skid breaking off narrow board on back. 3. Remove skid by pulling forward. YOUR SHIPMENT SHOULD CONSIST OF: RIP-1 RIP-2...
  • Page 6: Installation

    INSTALLATION ELECTRICAL CONNECTION WARNING!!!! DO NOT USE EXTENSION CORDS (VOIDS WARRANTY) Ground: The electrical outlet must be provided with an efficient ground, and the voltage and the frequency of the electrical line matches those indicated on the data plate. If unsure about the efficiency of the ground, have your electrical circuit checked by a qualified technician.
  • Page 7: Plumbing Information

    Voltage variation can cause erratic operation and serious damage to the electrical system. NOTE: Piper’s automatic steam and humidity systems MUST be connected to a source of clean and filtered water. The filter removes solid particles and dissolves minerals (such as what is commonly found in hard water) to prevent scale build-up on the water heating element.
  • Page 8: Operating Instructions

    OPERATING INSTRUCTIONS • Turn the power switch “ON”. • Set the thermostat to 100°F. Allow approximately 15-30 minutes to reach temperature • Set the humidity control to 3 to 4.5. At the proper setting your proofer door will have a light haze on it. This process will take approximately 15-30 minutes. If water beads up and runs down the door, the setting is too high.
  • Page 9: General Cleaning

    CAUTION: Prior to cleaning or maintenance, turn all switches “OFF” and disconnect the power. Stainless Steel and Aluminum: • Piper only approves soap and water for cleaning stainless steel. • NOTICE: Do NOT use chlorinated cleaners. Hardened Foods or Scale Deposits: •...
  • Page 10: Maintenance

    WARNING: Do not use any chlorinated or highly caustic cleaners, acids, ammonia or other corrosive cleaners. These may cause corrosion and/or damage to the stainless steel. Piper only approves soap and water for cleaning stainless steel. REQUIRED MONTHLY MAINTENANCE: •...
  • Page 11: Troubleshooting Guide

    Check water solenoid valve for sticking open. NOTE: Piper’s automatic steam and humidity systems MUST be connected to a source of clean and filtered water. The filter removes solid particles and dissolves minerals (such as what is commonly found in hard water) to prevent scale build-up on the water heating element.
  • Page 12: Replacement Parts Front

    REPLACEMENT PARTS FRONT ITEM NO. PART NUMBER DESCRIPTION 305612 MAGNET, S/S ENCASED 11-0000067-000 DOOR ASSEMBLY, PROOFER 305002 HANDLE, DOOR 305613 BUMPER, DOOR STOP 705484 SWITCH DISCONNECT, 3-POLE 30 AMP 705160 INDICATOR LIGHT, 250V 705705 THERMOSTAT, PROOFER 60-125 DEG KIT 705757 SWITCH, INFINITE 120V HUMIDITY CONTROL KIT 305012 HINGE...
  • Page 13: Replacement Parts Side

    REPLACEMENT PARTS SIDE ITEM NO. PART NUMBER DESCRIPTION 705532 BUZZER 305209 GASKET, LIGHT COVER 200001 GLASS, LIGHT COVER 4.5” x 4.5” 705366 TERMINAL BLOCK, 75A 3 POLE 705146 LIGHT BULB, 40W, 130V 705157 ROUND LIGHT SOCKET 104075 LIGHT SOCKET HOLDER...
  • Page 14: Replacement Parts Rear

    REPLACEMENT PARTS REAR ITEM NO. PART NUMBER DESCRIPTION 705426 RELAY, HUMIDITY, 120V 705476 SWITCH, FLOAT HUMIDITY LIQUID LEVEL 105077 FLOAT CHAMBER, HUMIDITY 705864 SOLENOID VALVE, HUMIDITY, 120V 701960 AQUA-FLOW, STEAM / HUMIDITY 701508 HUMIDITY NOZZLE 11-0000511-000 CHAMBER, PROOFER HUMIDITY 704300 ELEMENT, IMMERSION - HUMIDITY 120V, 1500W 305213 GASKET FOR HUMIDITY ELEMENT...
  • Page 15: Replacement Parts Fan Assembly

    REPLACEMENT PARTS FAN ASSEMBLY ITEM NO. PART NUMBER DESCRIPTION 102059 FAN COVER, PROOFER 705821 GUARD, FAN BLADE 704761 ELEMENT - U-SHAPE, 120V/750W 705846 FAN BLADE, RADIAL 6-1/4” 705847 FAN BLADE, RADIAL 4” 706400B MOTOR, SHADED POLE 12-0003807-000 BRACKET, MOTOR 408902 FINGE NUT...
  • Page 16: Replacement Parts Rip-1 Auto Humidity

    REPLACEMENT PARTS RIP-1 AUTO HUMIDITY ITEM NOTE: SHORT S/S N THIS IS MAD NOTE: SHORT THIS IS M UNLE DIME PROPRIETARY AND CONFIDENTIAL DETAIL A TOLE THE INFORMATION CONTAINED IN THIS FRAC DRAWING IS THE SOLE PROPERTY OF SCALE 1 : 4 PIPER PRODUCTS, INC.
  • Page 17: Replacement Parts Rip-1 Auto Humidity

    REPLACEMENT PARTS RIP-1 AUTO HUMIDITY ITEM NO. PART NUMBER DESCRIPTION 701915 BRASS FTG BULKHEAD ADAPTOR 1/8 701960 AQUA-FLOW #C-25 701508 S/S FTG NIPPLE 1/8 X 3 701540 BRASS PIPER COUPLER 1/8” 701016 NYLON MALE CONNECTOR PP4MC2 11-0000511-000 AUTO HUMIDITY STEAM CHAMBER...
  • Page 18: Wiring Diagram Rip-1 With Autofill

    Buzzer 2 4 3 water valve float switch 1500 watts WIRING DIAGRAM 300 South 84th Ave. PIPER WAUSAU, WI. 54401 RIP-1 AUTOFILL 120 volt PH. (715) 842-2724 The Food-Focused Equipment Company FAX (715) 842-3125 DRAWN BY: SCALE: DATE: BRANDS company...
  • Page 19: Wiring Diagram Rip-2 With Autofill

    1500 watts 1500 watts WIRING DIAGRAM 300 South 84th Ave. PIPER WAUSAU, WI. 54401 RP-30 & RIP-2 autofill 120 volt PH. (715) 842-2724 The Food-Focused Equipment Company FAX (715) 842-3125 DRAWN BY: SCALE:...
  • Page 20 Piper Products Service Department shall be final. Any defective parts to be repaired or replaced must be returned to Piper Products, Inc., 300 South 84th Avenue, Wausau, WI 54401, transportation charges prepaid, and they must be properly packed and tagged.
  • Page 21 Piper Products, Inc 300 South 84th Avenue Wausau, WI 54401 Phone: 715-842-2724 . FAX: 715-842-3125...

This manual is also suitable for:

Rip-2

Table of Contents