Safety Precautions
Places with overmuch
High-temperature
lampblack or steam
places forbidden.
forbidden
o
> 40 C
500mm
Should be firmly
Below connection
installed. Gradient
way of air duct is
installation
forbidden.
Overbending
Multiple bend
Maintenance Instructions
Regular maintenance is needed each year. The
impeller blades require thorough cleaning once in 6
months.
The technical maintenance includes periodic
cleaning of the surfaces from accumulated dust and
dirt. Use a soft dry brush or a soft cloth wetted or a
vacuum cleaner to remove dust.
Please don't damage the impeller.
Ÿ
Please don't bend impeller, blades.
Ÿ
Please don't use chemical and gasoil, benzene,
Ÿ
diluent to wipe the fan.
Please don't let water into motor and electric
Ÿ
parts.
Before any maintenances are undertaken please:
Stop fan in accordance to regulations and
Ÿ
disconnect all poles from mains supply.
Wait until impeller is stationary.
Ÿ
Ensure that the machine cannot be switched on
Ÿ
again.
The following safety notes must be observed
when maintaining the machine.
Periodical cleaning prevents to rotor to become
out-of-balance.
Vacuum-clean would be best.
Ÿ
www.breeze.com.vn | breezefans@breeze.com.vn
Installation height
should be more
than 2.3m.
> 2.3m
Please set up vent
and spot inspection
forbidden.
Duct
Adapter
< 0.8m
Outlet closed to crook
Pipe diameter shrinks at
connecting part
Ceiling Mounted Fan
Before installing this product, ensure that the voltage
Ÿ
and frequency consistent with the product nameplate.
Direct spraying or cleaning by water or other liquid is
Ÿ
forbidden. This may cause short circuit or electric
shock.
Installation on window or outdoor is forbidden.
Ÿ
When connected to power supply, all-pole power
Ÿ
switch with more than 3mm contact separation is
necessary to be installed on the power supply circuit.
Please do the connection according to the local
electrical equipment technical regulations.
Avoiding air reflux via open air flue or other fired
Ÿ
equipment is necessary.
Earthing device is necessary. Or will cause electric
Ÿ
shock when breaking down or electric leakage occurs.
Compressed-air must not be used. Dirt could be
Ÿ
pressed into the bearings and causes
consequential damage.
If the power line is damaged, to avoid danger, it
Ÿ
should be changed by the maintenance
department or qualified professionals.
Clean fan:
Remove louver.
Ÿ
Remove casing.
Ÿ
Remove screws and put out impeller.
Ÿ
Clean louver.
Ÿ
Clean casing.
Ÿ
Clean impeller.
Ÿ
Clean outlet duct.
Ÿ
Assembly the fan.
Control whether installation is correct:
Impeller must rotate free
Ÿ
The gap between impeller and casing must be
Ÿ
regular.
Checking direction of rotation is correct.
Ÿ
Insert louver.
Install the outlet fan into air duct.
Connect electric supply of motor.
Put the fan into operation after cleaning.
CPD Series
62