BULLET CAMERAS CORRECT (right) AND WRONG (left) POSITIONS:

4.3 Cameras standard switching

To switch cameras standard, use the remote control (below) and wire it to the coax cable of the relevant camera.
(The remote control is not supplied with the device; it has to be ordered.)
To switch the standard, press the  key to power on the remote control and follow the instructions given. By default, ca-
meras are in AHD mode.
To switch the cameras to the 960H standard, select the
AHD option.
To switch the cameras to the Full HD (1080P) standard,
select the CVBS option.
For fixed or varifocal lens cameras, press  until the
selection rectangle marks the chosen option.
To save the setting, keep
For motorized cameras:
- Press OK to enter the OSD menu, shown on the screen
connected to the DVR.
- Press
to move the arrow cursor next to "Exposition".
- Press  thrice, then OK to access the "Hidden" menu.
- Position the arrow cursor next to "Monitor Out" and
press OK until the chosen option (AHD or CVBS) is shown.
- Position the cursor next to "Return" and press OK to go
back to the main menu
- Position the cursor next to "Exit" and press OK to save
the settings and exit the OSD menu.
To enter OSD menu, press the OK key at the centre.
pressed for 5 seconds.
Quick Guide - Telecamere AHD Full HD - 090010937
16
For motorized models,
press...
to zoom in
to zoom out
 to move the focus far
 to move the focus near