2.5

Terms (in alphabetical order)

In this section the terms necessary to understand this manual are explained.
* These terms are explained in more detail in the following text.
Alarm module
Constant pressure (P
Constant pressure
regulator unit
Dome loaded pressure
regulator
Double dome loaded
pressure regulator
Gas inlet pressure (P
Inlet pressure
monitoring
Mixed gas output (Q
WITT-GASETECHNIK GmbH & Co KG
Gas Safety- & Control Equipment
Page 6 of 27
: The alarm module is on the separate control housing. It signals insuf-
ficient gas inlet pressure* and indicates the corresponding gas.
) : The individual gases are reduced to the constant pressure by the
m
constant pressure regulator unit*. The constant pressure is the pres-
sure of the individual gases from the dome or double dome loaded
pressure regulators.
: The constant pressure regulator unit comprises dome or double dome
loaded pressure regulators and a pilot pressure regulator*. The gases
to be mixed are regulated to the required constant pressure* by the
constant pressure regulator unit.
: A dome loaded pressure regulator functions similarly to a spring-
loaded pressure regulator, however in this case the force from the
spring is replaced by the pilot gas pressure on a membrane. If several
dome loaded pressure regulators are subjected to the same pressure-
regulated pilot gas, then the same constant pressure* is established at
each of the dome loaded pressure regulators.
: A double dome loaded pressure regulator* can be considered as two
single dome loaded pressure regulators*. Both chambers in the dome
loaded pressure regulator are subjected here to a gas, the pilot gas*;
this results in exactly the same pressures being established at the
outlets of the dome loaded pressure regulator. Together with the pilot
pressure regulator*, the dome and double dome loaded pressure
regulators in a gas mixer form the constant pressure regulator unit*.
)
: The pressure provided by the supplies for the individual gases is
v
termed the gas inlet pressure. A differentiation is made between static
and dynamic pressure. If no mixed gas is produced, no gas flows. The
pressures now present at the inlet to the gas mixer are static pres-
sures. However, if mixed gas is produced, the gas inlet pressure
drops to the dynamic pressure as a function of the sizing of the gas
supply.
The static pressure is always higher that the dynamic pressure. The
static pressure (without mixed gas production) must not exceed the
maximum permitted inlet pressure. The dynamic pressure (during the
production of mixed gas) must not drop below the minimum required
gas inlet pressure (in the case that inlet pressure monitoring is acti-
vated, this would result in the triggering of the alarm).
: The inlet gas pressure monitoring comprises pressure switches* or
pressure transmitter* and an alarm module*. It is used to check for the
minimum gas inlet pressure required. The inlet pressure is only moni-
tored to check if the inlet pressure drops below the min. inlet pressure
given in the technical data.
)
: The mixed gas output is the mixed gas flow that the gas mixer can
M
produce in the normal operating state (P=1 bar; T=15 °C). The mixed
gas output will depend on the mixture this value relates to air.
Salinger Feld 4-8
D-58454 Witten
: +49 (0)2302 89010
Fax: +49 (0)2302 89013
www.wittgas.com
witt@wittgas.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mg 100-2meMg 200-2meMg 50-2me pvduMg 100-2me pvduMg 200-2me pvduMg 50-2me gb ... Show all

Table of Contents