  • Page 1 USE AND MAINTENANCE MANUAL BVM 3 5 1 CERT. N° 9105 BNVD UNI EN ISO 9001: 2000 CERT. N° 9191 BNVN UNI EN ISO 14001:2004...
  • Page 3: Declaration Of Conformity

    D ECLARATI ON OF CON FORM I TY La BI AN CH I VEN D I N G GROUP S.p.A. Corso Africa, 9 - 24040 Zingonia di VERDELLI NO ( BG) I t alia hereby declares under it s own liabilit y t hat t he fam ily of coffee m achines - m odel: BVM 3 5 1 complies with the Basic Safety Reqirements as specified in the Directives listed below: 7 3 / 2 3 CEE Low Te n sion ⇒...
  • Page 4 INFORMATION TO THE USERS Under Legislative Decree 25 September 2007, no.185 and art. 13, Legislative Decree 25 July 2005, no.151 “Implementation of Directives 2002/95/EC, 2002/96/EC and 2003/108/EC, regarding the reduction of use of hazardous substances in electrical and electronic equipment as well as waste disposal”. The barred waste container symbol on the equipment means that the product, at the end of its service life, must be disposed of separately from the other types of waste.
  • Page 5 BEFORE USI NG THE MACHI NE, READ THI S MANUAL CAREFULLY FOR I TS CORRECT USE I N AC- CORDANCE WI TH THE CURRENT safet y STANDARDS. ATTEN TI ON : I m port ant safet y indicat ions READ t he inst ruct ion m anual m achine carefully before using t he m achine For any service or m aint enance sw it ch off t he m achine ATTEN TI ON : m achine swit ched on ATTEN TI ON : hot part s in cont act !
  • Page 6: Operation

    I N D EX 1 .0 I N TROD UCTI ON 1 .0 I N TROD UCTI ON 1 .1 D ir e ct ion s a n d in st r u ct ion s for ope r a - 1.1 Direct ions and inst ruct ions for operat ors t or s 1.2 General direct ions and inst ruct ions...
  • Page 7 – I t is however Bia n ch i Ve n din g Gr ou p‘s facult y, when dee- The st andard fact ory condit ions provide for m achine delivery m ed opport une and for valid m ot ives, t o adj ourn t he m anuals wit hout wat er in t he int ernal circuit s.
  • Page 8 3 .0 TECH N I CAL SPECI FI CATI ON S 2 .0 D ESCRI PTI ON OF TH E M ACH I N ES Th e su per au t om at ic BM V 3 5 1 cof f ee m ach in es h av e been 3 .1 M a ch in e dim e n sion s a n d w e igh t s engineered and const ruct ed for t he brewing of espresso coffee and ot her hot drinks.
  • Page 9 5 .0 I N STALLATI ON 4 .0 TRAN SPORT The machines are fitted with height-adjustable feet. Ensure that 4 .1 Pa ck in g height is adj ust ed ident ically for all t he four base feet . The posit ioning suppor t sur face m ust be evenly levelled, dr y, The m achine is delivered in one single cardboard package, wit h st rong and st able, t o be posit ioned at a height of at least 110 cm int ernal expanded polyst yrene safet y padding insert s.
  • Page 10 I n bot h cases, a different ial swit ch m ust be arranged upst ream of t he power supply cable, com plet e wit h m agnet ic release swit ches com pat ible wit h t he dat a provided on t he m achine rat ing plat e. The relat ive cont act s m ust be provided wit h an opening equal or great er t han 3m m .
  • Page 11 6 . COM M I SSI ON I N G 6 .1 M a ch in e con t r ol com m a n ds a n d de vice s Fig. 6 .1 St eam dispensing t urn- knob Fu n ct ion s: The boiler pressure gauge ( 2) wit h a 0 t o 2.5 bar scale, displays Boiler pressure gauge...
  • Page 12 6 .3 H ow t o h e a t u p a dr in k 7 .0 · Plunge t he st eam dispenser nozzle ( 6) direct ly int o t he liquid t hat requires heat ing. 7 .1 OPERATI ON ·...
  • Page 13 All values in t he display m essages m ust be considered as t he 4 . W ASH I N G m achine default values. Washing The above m essage is displayed once t he washing procedure is st art ed up and st ays on display unt il t he end of t he washing operat ions.
  • Page 14 M EN U 2 ( SALES) Descript ion Unresettable Resettable Unreset t .t ot al select ions Tot al select ions Displays t he unreset t able t ot al select ions St rong coffee select ions count er. The m axim um value is 16777251. Two st rong coffee select ions Tot al select ions Displays t he reset t able t ot al select ions count er.
  • Page 15 Coffee filters Wat er load t im eout - - - s Set s t he wat er load m anagem ent t im eout . Sets the coffee filter decounter value. - - - - - - - The ent ry dat a allowed here is: 0 t o 250 s. The ent ry dat a allowed here is: 0 t o 9999999 Boiler load t im eout Elect ro valves...
  • Page 16 Param et ers: 8 .0 SOFTW ARE I N STRUCTI ON S 5. Read- off t im e: t em porary value 2.0 s 6. I ndependent pum p t im eout : t o be program m ed in t he t im ing and t hresholds m enu 8 .1 FUN CTI ON M AN AGEM EN T 7. Water empty timeout: fixed value 2.0 s...
  • Page 17 ● Press the dispensing stop key (Key 8). (if the group does not Managem ent is not t aken int o considerat ion if eit her t he boiler load det ect door opening and closing, t he group will not run a com - alarm ( E21) or t he pressure swit ch alarm ( E20) is present . plet e cycle at subsequent select ion) The resist ance is swit ched off independent ly t o t he pressure swit ch ● Press a non-allowed selection key. In this case, the decaf pre-...
  • Page 18 Once t he addit ional wat er dose as program m ed by t he “Am erican TROUBLE SH OOTI N G coffee” elect ro valve has been dispensed and t he group has gone ● The grinder timeout expires (Timing and thresholds menu), back int o it s rest posit ion, t he dispensing cycle is over.
  • Page 19 cannot be t aken int o considerat ion. COFFEE GROUN D S D ECOUN TER M AN AGEM EN T I f in t he 3 subsequent select ions t he coffee dispensing t im e does I nput s and out put s involved: not reach 18”...
  • Page 20 During t his procedure, t he following non- am endable m essages AUTOM ATI C D RI N K- STOP M AN AGEM EN T will com e up on display: This m anagem ent m ode is devised for t he following drinks: DOWNLOAD DATA ● Short (condensed) coffee dose WAI TI NG...
  • Page 21 9 .0 M AI N TEN AN CE 2. Read- off and writ ing of t he relat ive m essages. All t he language m essages are st ored int o t he hand- held unit . Said dat a will be 9 .1 SOFTW ARE FUN CTI ON M AN AGEM EN T m anaged by t he VSPS windows program and by t he relat ive alt erat ion and am endm ent program s.
  • Page 22 Unless otherwise specified, all maintenance operations m ust be carried out w hen the m achi- DATA DI SPLAY ne is totally pow ered dow n to OFF, it has cooled The following m essage com es up on display in line 2: dow n and the m ains socket is unplugged.
  • Page 23 9 .4 Acce ss t o t h e in t e r n a l m a ch in e pa r t s Rem ove screws 1 ( Fig. 8.3) and close t he grinder coffee cont ainer lid.
  • Page 24 1 0 . PUTTI N G TH E M ACH I N E OUT OF SERVI CE 10.2 Putting the machine out of service definitely 1 0 .1 Pu t t in g t h e m a ch in e ou t of se r vice t e m por a r ily ·...
  • Page 25 1 2 .0 ALARM S AN D SI GN AL M ESSAGES A dist inct ion is kept bet ween alarm and signal m essages. Signal m essages are a special t ype of alarm t hat will not cause int errupt ions t o t he st andard m achine operat ions.
  • Page 26 ALARM S D ESCRI PTI ON I N TERVEN TI ON REQUI RED E46 EV decount er Elect ro valve decount er warning. Each pum p m anagem ent act ivat ion decreases t he coun- t er t hat is displayed in t he prevent ive act ion m enu ( 6) .When t he decount er is down t o zero, t he signal is t riggered and displayed only in t he m aint enance m ode.
  • Page 29 FIRST INSTALLATION FORM WARRANTY ACTIVATION Dear Customer, The hereby form is a necessary feed-back for the Bianchi Vending Group S.p.A. Considered this form as formal report of first installation, the BVG, kindly, asks you to fill this form in, once the process of first installation of the unit has been performed and to return it back to us. Please send it via FAX or e-mail as specified below.
  • Page 31: Warranty Claim

    WARRANTY CLAIM Dear Customer, The hereby form is a formal warranty claim to be sent via fax or e-mail as specified below. Please, to describe the matter occured in the dedicated box. Beware, the BVG, could ask to return the faulty component back for quality inspection purposes.
  • Page 33 BVM351 SUPERAUTOMATIC – KEYBOARD LAYOUT PROGRAMMING MODE MAINTENANCE MODE To enter the programming mode, press the To enter the maintenance mode, press the SELECTION MODE STOP button (nr. 8) for 4 seconds DECA button (nr. 4) for 4 seconds Button Functions Button Functions...
  • Page 34 Cod. 11112921 Ediz. 10/2009...