Download Print this page
Pyronix EQUINOX 10/15 Installation
Pyronix EQUINOX 10/15 Installation

Pyronix EQUINOX 10/15 Installation

Advertisement

Available languages

Available languages

Quick Links

15M
A1
14M
Horizontal Coverage
at Maximum Range
12M
Setting
10M
LENS 2
o
VOLUMETRIC
90
8M
6M
54 ZONE EDGES
3 PLANES
4M
2M
A2
PIR Range Adjustment
2m
(6.6ft)
Microwave
Microwave
Range Adjustment
Range Adjustment
-
+
15m
(50ft)
LED On
LED On
LED Off
LED Off
PC 1
PC 1
Maximum
PC 2
PC 2
2m
Range
(6.6ft)
T T
T T
N N
C C
- 12V +
- 12V +
15m
(50ft)
2m
(6.6ft)
Microwave
Microwave
Range Adjustment
Range Adjustment
-
+
15m
(50ft)
LED On
LED On
LED Off
LED Off
PC 1
PC 1
Minimum
PC 2
PC 2
Range
2m
(6.6ft)
T T
T T
N N
C C
- 12V +
- 12V +
15m
(50ft)
D1
Analog Pulse Count Options
Analogue pulse count measures the length of time an output
signal stays over the thresholds. If the amplifier output is over
the threshold for a given length of time then an alarm is raised.
To select PC2 remove pulse count header from the link pins.
PC1
1
2
3
PC2
0.3 - 3.0 m/s
D3
Microwave adjustment
MICROWAVE
ADJUSTMENT
5m
Equinox E / 15
5m
10m
15m
Minimum range
SENSOR
5m
Equinox 10
5m
10m
15m
Microwave
Microwave
Range Adjustment
Range Adjustment
-
+
LED On
LED On
LED Off
LED Off
PC 1
PC 1
PC 2
PC 2
Equinox E / 15
T T
T T
N N
C C
- 12V +
- 12V +
TEST LINK (IMPORTANT)
15m
The default for this link, "LED ON" is Test Mode
5m
10m
15m
with all indication enabled. Following
commissioning the link should be changed to
Maximum range
"LED OFF" To place the detector into
operational mode.
10m
Equinox 10
5m
10m
15m
Wall fixing knockouts
B1
Mark wall for fixing
positions.
Cable entry knockouts
B2
15M
B3
50FT
EQ E / 15
Mounting holes
Replace Printed
circuit board.
EQ 10
= 225g (7.94 oz) without bracket
C1
Kg
3mm
(0.12")
EQ E / 15
EQ 10
62mm (2.44")
D2
PCB layput
MICROWAVE
E1
DETECTOR
9 - 16Vdc
25mA
@12Vdc
LEDS
E2
RELAY
Microwave
Microwave
Range Adjustment
Range Adjustment
-
+
LED On
LED On
LED Off
LED Off
E3
PYRO
PC 1
PC 1
PC 2
PC 2
D4
T T
- 12V +
- 12V +
T T
N N
C C
Pulse
WARRANTY
count
TEST LINK
select
This product is sold subject to our standard warranty
conditions and is warranted against defects in workmanship
for a period of two years.
In the interest of continuing improvement of quality,
customer care and design, Pyronix Ltd reserve the right to
amend specifications without giving prior notice
The following note applies only to FCC models -
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference and 2.
This device must accept any interference received, including
interference which may cause undesirable operation.
INSTALLATION
Drill fixing
holes.
1. Remove case lid by unscrewing fixing screw
and remove the PCB.
Use 5.0mm
(Do not touch Pyro sensor
drill bit.
2. Choose suitable wall fixing holes.
3. Mark wall for fixing positions (Do not route wires near mains
cabling, avoid vibrating surfaces, and only use solid wall).
4. Drill fixing holes.
5. Fix case to wall.
6. Replace PCB (Do not touch Pyro sensor
7. Rotate microwave adjustment to select the required range
and if required adjust the PIR range as illustrated in
8. Refit lid to case and fasten.
Final Steps -
1. Apply power and wait 2 to 3 minutes for the detector to stabilise
Microwave
Microwave
Range Adjustment
Range Adjustment
-
+
2. Replace cover and walk test the detector to verify the sensitivity and
LED On
LED On
LED Off
LED Off
check that alarms are indicated at the control panel.
PC 1
PC 1
PC 2
PC 2
3. The three LEDs are colour coded as follows-
T T
- 12V +
- 12V +
T T
N N
C C
PIR detection = Green
Microwave detection = Orange
B4
Alarm = Red
4. If LEDs are to be disabled remove the test link header.
It is recommended that the LEDs are disabled after installation to prevent
potential intruders from walk testing the system.
POTENTIAL FALSE ALARM HAZARDS
1. Direct sun light on detector may cause a PIR to activate.
2. False Alarms may be caused by pets and animals.
3. Do not mount detectors near heaters.
4. Open windows may induce false alarms caused by draughts and
moving objects .
DIAGRAMS
A1
Horizontal coverage pattern
A2
PIR range adjustment
42mm (1.56")
B1
Wall fixing knockouts
B2
Mounting holes
Control
ZONE
TAMP
B3
ZONAS
Cable entry knockouts
Panel
24HR
ZONES
B4
Case lid screw fitting
C1
Measurements and weight
D1
Analog pulse count options
D2
PCB Layout
D3
Microwave range adjustment
E1
Wiring to control panel
E2
Tamper operation
Normal = Cover closed
12V
60V
Alarm = Cover open
50mA
50mA
SPECIFICATIONS (QUICK REFERENCE)
Model:
T T
T T
Colour:
Range Adjustment
Microwave
Range Adjustment
Microwave
-
+
LED On
LED On
LED Off
LED Off
PC 1
PC 1
PC 2
PC 2
Casing:
T T
T T
N N
C C
- 12V +
- 12V +
ALARM
NORMAL
Detection method:
Detection Zones:
Detection speed:
Operating Voltage:
Quiescent Current:
NORMAL
ALARM
Alarm
Alarm
Relay Output:
Contact Resistance
Mounting Height:
Tamper Switch:
Storage Temp:
Operating Temp:
Emissions:
Immunity:
GB
,
B4
)
D4
B1
B2
).
D4
D3
A2
D2
Pyro sensor
D4
E3
Relay contacts
Normal = No movement
Alarm = Cover open
Equinox 10 - 15 and E
White
3mm ABS, 0.4 mm HDPE in lens area
PIR = Dual element Pyroelectric
Microwave doppler shift sensor =
FET oscillator with twin patch antennas
Lens 2, 54 zone edges
.
0.3 - 3m / s
9 to 16 volts DC (12V nominal)
25 mA at 12V
Current:
Alarm LEDS enabled = 45mA at 12V
Current:
Alarm LEDS Disabled = 15mA at 12V
50mA, 60VDC / 42VAC (RMS)
<10Ohms
1.8 to 2.4m (6 to 8 ft)
Normally closed voltage free contacts
- 40 c to 60 c
14 f to 140 f
-30 c to 60 c
14 f to 140 f
EN55022 class B
To new European standard EN50130-4
R
EQUINOX 10/15
EQUINOX 10/15
& EQUINOX E
& EQUINOX E
Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, ENGLAND
Customer Support:
+44(0)845 6434 999 (local rate)
or +44(0)1709 535225
Hours: Mon to Fri, 8:00am till 6:30pm
Email: customer.support@pyronix.com
Website: www.pyronix.com
R
PYRONIX
0C03
This product is approved for use in the
Residential, Commercial and Light Industrial Environment.
TS50131-2-4
EN50131-1
2
PD6662:2004
Security Grade 2
Environmental Class 2
This product complies with TS50131-2-4. at security grade 2,
environmental class 2.
UK = Suitable for use with systems installed to PD6662:2004 (AMD)
EXPORT = Suitable for use with systems installed to EN50131-1
RINS302-9

Advertisement

loading

Summary of Contents for Pyronix EQUINOX 10/15

  • Page 1 TEST LINK (IMPORTANT) EN50131-1 In the interest of continuing improvement of quality, Contact Resistance <10Ohms customer care and design, Pyronix Ltd reserve the right to PD6662:2004 Mounting Height: 1.8 to 2.4m (6 to 8 ft) amend specifications without giving prior notice The default for this link, “LED ON”...