VZ710
art.nr. 066566
POORTEN
PORTES
ROLLUIKEN
ZONWERING
VOLETS
PROTECTION SOLAIRE
MONTAGE HANDLEIDING
NOTICE DE MONTAGE
MOUNTING INSTRUCTION
MONTAGE ANWEISUNG

Advertisement

loading
Need help?

Need help?

Do you have a question about the VZ710 and is the answer not in the manual?

Questions and answers

Summary of Contents for Harol VZ710

  • Page 1 MONTAGE HANDLEIDING NOTICE DE MONTAGE MOUNTING INSTRUCTION MONTAGE ANWEISUNG VZ710 art.nr. 066566 POORTEN ROLLUIKEN ZONWERING PORTES VOLETS PROTECTION SOLAIRE...
  • Page 2 Dear Customer, Cher Client, merci d’avoir choisi une structu- Sehr geehrter Kunde, vielen Dank für die dank u voor uw keuze van een HAROL thanks for having chosen a HAROL cover of re HAROL de la série VZ. Wahl eine HAROL Abdeckung der Serie overkapping van de serie VZ.
  • Page 3 MONTAGE - MOUNTING VZ710 MONTAGESTAPPEN ETAPPES DE MONTAGE MOUNTING STEPS MONTAGESCHRITTEN TUSSEN-STAPPEN ETAPPES INTERMEDIARES WITHIN-STEPS ZWISCHEN-SCHRITTEN 03/2022 | ...
  • Page 4 MONTAGE - MOUNTING VZ710 VZ710 min. 275 max. 1600 min.125 millimeter / millimètre 03/2022 | ...
  • Page 5 MONTAGE - MOUNTING VZ710 DIN 933 DIN 7981 M6 x 40 4,8 x 22 DIN 934 DIN 125 type type P.V.C. type type ALU. A 279 03/2022 | ...
  • Page 6 MONTAGE - MOUNTING VZ710 03/2022 | ...
  • Page 7 MONTAGE - MOUNTING VZ710 DIN 7982 M4,2 x 9,5 03/2022 | ...
  • Page 8 MONTAGE - MOUNTING VZ710 CONTROL(E) B1 = B2 & D1 = D2 (+/- 2mm) (+/- 2mm) 03/2022 | ...
  • Page 9 MONTAGE - MOUNTING VZ710 (NL) CONTROLEER OF ER TENMINSTE NOG TWEE TOT DRIE SLAGEN KOORD OP DE KABELSCHIJF BLIJVEN. (FR) VEILLEZ À CE QUE LA CORDE SE DÉROULE EN DESSOUS DE LA POULIE. (EN) CHECK THAT AT LEAST 2 OR 3 TURNS OF CABLE ARE LEFT ON THE CABLE PULLEY.
  • Page 10 MONTAGE - MOUNTING VZ710 zie p.12 voir p.12 see p.12 sehen p.12 03/2022 | ...
  • Page 11 MONTAGE - MOUNTING VZ710 Tabel VEERAFSTAND R (in mm) Table de la d istance R du ressort (en mm) Table spring d istance R (in mm) Tabelle der Federspannlänge R (in mm) Tabel veerafstand R (in mm) AFSTAND DISTANCE ENTFERNUNG...
  • Page 12 MONTAGE - MOUNTING VZ710 DIN 7982 M4,2 x 9,5 03/2022 | ...
  • Page 13 MONTAGE - MOUNTING VZ710 DIN 7982 M4,2 x 13 www.somfy.com OREA 50 WT 25/17 OREA 50 WT 40/17 see instruction manual Somfy (included) Orea 25/17 LT50 RTS zie gebruikershandleiding Somfy (bijgevoegd) Orea 40/17 LT50 RTS voir manuel d’instruction Somfy (inclus)
  • Page 14 MONTAGE - MOUNTING VZ710 03/2022 | ...
  • Page 15 MONTAGE - MOUNTING VZ710 GEKOPPELD - COUPLE - LINKED - GEKOPPELT aparte kasten Caisson séparé sepated boxes aparte Teilen /3/4 zie p.4 voir p.4 see p.4 sehen p.4 zie p.6 voir p.6 see p.6 sehen p.6 03/2022 | ...
  • Page 16 MONTAGE - MOUNTING VZ710 zie p.7 voir p.7 see p.7 sehen p.7 DIN 934 DIN 966 M5 x 25 zie p.7 zie p.8 voir p.7 voir p.8 see p.7 see p.8 sehen p.7 sehen p.8 03/2022 | ...
  • Page 17 MONTAGE - MOUNTING VZ710 UITZONDERING: KOPPELINGSMETHODE VAN 2 ZIJGELEIDERS EXCEPTION : MÉTHODE POUR ACCOUPLER 2 GLISSIÈRES EXCEPTION : METHOD FOR COUPLING 2 GUIDE RAILS AUSNAMEFALL : KOPPLUNGSMETHODE VON 2 FÜHRUNGSSCHIENEN standaardsteun in het midden / point de fixation standard au milieu / standard base attachment point in the middle / Standard Dachhalter in die Mitte verhoogde steun in het midden / support prolongé...
  • Page 18 MONTAGE - MOUNTING VZ710 F.A.Q. Uw Harol schermen worden 100% Les bannes de Harol sont 100% Your Harol awnings are 100% Ihre Harol Markisen werden gründlich gecontroleerd vooraleer zij het contrôlées avant de partir de l’usine. checked before they leave the kontrolliert, ehe sie das Werk verlas- bedrijf verlaten.
  • Page 19 MONTAGE - MOUNTING VZ710 Doeken staan in ontrolde toestand • Slechte koppeling van de • Mauvais couplage des axes • Bad fitting of fabric rolls. Turn one • Schlechte Kopplung der niet gelijk: doekrollen. Verdraai één van de d’enroulement. Tourner un des axes of the tubes 1/4 of 1/2 turn.