  • Page 1 Flush Top-surface Built-in Stainless Steel Gas Cooktop ED-GC905SS ED-GC705SS ED-GC604SS...
  • Page 2 This manual explains the proper installation and use of your appliance, please read it carefully before using even if you are familiar with the product. The manual should be kept in a safe place for future reference. In case of failure, only the Authorized Technical Service may repair this hob.
  • Page 3: Safety Instructions

    Children’s Safety ⚫ The cooking zones will become hot when you cook. Therefore, always keep small children away from the appliance. ⚫ The appliance is not intended for use by young children or infirm persons without supervision. ⚫ Young children should be supervised to ensure that they do not play with the appliance. Safety During Use ⚫...
  • Page 4 AS/NZS 3000 – Electrical Installations (Wiring Rules) Building codes Any other relevant statutory regulations. ⚫ Check the gas type label on the underside of the hotplate, adjacent to the gas connection to ensure it corresponds to the installation gas supply. If in doubt contact the supply authority.
  • Page 5: Product Description

    30.5MJ/h 29.5MJ/h LPG: ED-GC705SS 1W+1R With 2 types for Front 39.6MJ/h +2SR+1A option 39.0MJ/h LPG: ED-GC905SS 1W+1R With 2 types for Front 39.6MJ/h +2SR+1A option 39.0MJ/h *Note: For burner: W=Triple Ring Wok burner, R=Rapid burner, SR=Semi-Rapid burner, A=Auxiliary burner...
  • Page 6 Dimensions Size Connection Input weight (h x w x d) mm ( w x d)mm Power ED-GC604SS 85x580x500 552 x 470 12.5Kgs 220-240V/50Hz 0.5W ED-GC705SS 85x680x500 552 x 470 15.7Kgs 220-240V/50Hz 0.5W ED-GC905SS 85x860x500 827 x 470 18.7Kgs 220-240V/50Hz 0.5W...
  • Page 7: Installation

    Installation Before Installation: ⚫ Before cutting into any bench tops, ensure the minimum clearances to walls, adjacent surfaces and overhead surfaces required by the relevant gas appliance installation code (see above) will comply. Dimensions are specified in millimeters (mm) Overhead cupboards and range hood = 650 mm. Side and rear clearance = 200 mm to any burner edge.
  • Page 8 2. Place Burner Box Apply the adhesive sealing tape to the underside lip of the burner box. Shown at G opposite. Place burner box into cutout hole and fit clamping brackets to clamp the hotplate to the bench. 3. Fit Burners And Trivet. Replace burners and ensure they are correctly repositioned over the ignitor (S) and thermocouple (T).
  • Page 9 Wiring diagram(Applicable to model: ED-GC604SS) (ED-GC705SS, ED-GC905SS) Wiring diagram for Remove the internal earthing\ 4. Gas Connection (OPTIONAL) Install in accordance with relevant gas standards and/or codes of practice applicable. Connect the elbow fitting to the appliance gas manifold connection, and check that seals between the elbow and manifold connection are in place and in good condition.
  • Page 10: Setting The Gas Pressure

    inside of the cupboard door so it is clearly visible for any service technician. SETTING THE GAS PRESSURE: Fit a manometer with a 6 mm rubber hose to the test point on the regulator (for natural gas). Light Triple Ring and Auxiliary burner on and adjust test point pressure to 1.00 kPa. Turn the two burners off and on again and recheck the pressure is same as set previously or adjust as required.
  • Page 12: Gas Conversion Instructions

    Change the NG regulator to LPG by a qualified Natural Gas regulator is to be fitted and adjusted person. For model ED-GC705SS, ED-GC905SS ADJUSTED FOR NATURAL GAS 1.0kPa ADJUSTED FOR ULPG 2.75KPa NOZZLES Gas consumption,...
  • Page 13: Start Using Your Appliance

    Start Using Your Appliance ED-GC604SS ED-GC705SS, ED-GC905SS Description Explanation These show which zone is under control. Zone indicators Flame power Flame power of the zones, is the lowest and is the highest. The hotplates are fitted with mains powered electronic spark ignitors, so must be connected to mains power supply (i.e.
  • Page 14 gas control knob to activate the spark ignition. Once the burner is alight continue to depress the gas control knob for 5 – 10 seconds to allow the flame safeguard to activate. If when you release the gas control knob, the burner flame goes out the flame safeguard has not heated up enough so repeat the ignition procedure after waiting 1 minute for gas to disperse.
  • Page 15: Maintenance And Troubleshooting

    Maintenance & Troubleshooting Cleaning and maintenance should be carried out with the appliance cold especially when cleaning the enameled parts. Avoid leaving alkaline or acid substances(lemon juice, vinegar etc.) on the surfaces. STAINLESS STEEL The stainless steel hob of the hotplate must be cleaned regularly (e.g.
  • Page 16: Troubleshooting

    TROUBLESHOOTING Servicing of the hotplates must only be done by an authorised service representative (see back of this booklet) and the hotplate must not be modified. Power must be disconnected before any servicing or maintenance is conducted. DO NOT MODIFY THIS APPLIANCE. It is recommended the hotplate serviced by an authorized person at least every 2 years.