Download Print this page

Advertisement

C O N TR O L
BO A RD FO R
BA R RIER S
U SER
M A N U A L

Advertisement

loading
Need help?

Need help?

Do you have a question about the DELMA SIRIO 4-24V and is the answer not in the manual?

Questions and answers

Summary of Contents for Bame DELMA SIRIO 4-24V

  • Page 1 C O N TR O L BO A RD FO R BA R RIER S U SER M A N U A L...
  • Page 2: Table Of Contents

    SIRIO 4 - 24V SUMMARY 1. ELECTRIC CONNECTIONS 2. BASIC SETTINGS 3. WORKING TIME ( AUTOMATIC ) 4. WORKING TIME ( PROFESSIONAL ) 5. REMOTE CONTROLS 6. TRIMMERS AND ADJUSTMENTS 7. DIP-SWITCHES 8. EXTERNAL BOARDS 9. LEDS When installing the device, insert a switch with a contact opening of at least 3mm which ensures the equipment omni-polar disconnection from the power supply.
  • Page 3 TECHNICAL SPECIFICATIONS • Double limit switch input open close • Motor force (speed) adjustable from 50-100%.using a trimmer. • Softstart (slow motor start) • 1 to 60” stand-by time adjustment via trimmer. • 0.1 to 3.0” obstacle detection triggering time adjustment via trimmer. •...
  • Page 4: Electric Connections

    1. ELECTRIC CONNECTIONS POWER SUPPLY 24VCC 1 2 3 4 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 LIMIT SWITCH MOTOR BLU - RED...
  • Page 5 ELECTRIC CONTACTS 28-29 POWER SUPPLY POWER SUPPLY 24VCC MOTOR 1. BLUE 2. RED LEFT 5-13-14-15 LIMIT SWITCH 5. + LIMIT SWITCH ( RED ) BARRIER 13. COMMON LIMIT SWITCH ( BLACK ) 14. OPEN LIMIT SWITCH ( PINK ) 15. CLOSE LIMIT SWITCH ( BROWN ) 28-29 POWER SUPPLY POWER SUPPLY 24VCC...
  • Page 6 1. ELECTRIC CONNECTIONS POWER SUPPLY 24VCC 1 2 3 4 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 ANTENNA FLASHING LIGHT ALARM OPEN CLOSE TRANSMITTER RECEIVER BUTTON BUTTON OPEN BARRIER INDICATOR 24Vdc 3W max...
  • Page 7 ELECTRIC CONTACTS 9-10 FLASHING LIGHT 24Vcc 9. +24 Vdc FLASHING LIGHT 10. -24 Vdc FLASHING LIGHT 16-17 OPEN BUTTON 16. OPEN 17. COMMON 18-17 CLOSE BUTTON 18. CLOSE 17. COMMON 19-22 EMERGENCY STOP 19. STOP ( NC ) ( INSERT A JUMPER IF NOT USED ) 22.
  • Page 8: Basic Settings

    2. BASIC SETTINGS BUTTON LED FOR START ERRORS LED FOR TRANSMITTERS LED FOR PROGRAMMATION SPEED PAUSE OBSTACLE DETENCTION TIME FO2 = FIRE ALARM (NO) F01 = OPENING LIMIT SWITCH (NO) FC1 = CLOSING LIMIT SWITCH (NO) APR = OPEN (NO) CHI = CLOSE (NO) STP = EMERGENCY STOP (NC) FTC = PHOTOCELLS (NC)
  • Page 9 3. WORKING TIME AUTOMATIC learning Slow down is setted by the board RELEASE THE BARRIER AND MOVE THE ARM IN 45° PRESS AND KEEP PRESSED P1\SET BUTTON FOR 5 SECONDS THE YELLOW LED START BLINKING RELEASE THE BUTTON IN 3 SECONDS PRESS AGAIN THE BUTTON P1\SET THE BARRIER PERFORM A BRIEF REDUCED SPEED OPENING (If motor turns in reverse invert wires and start procedure again from the begnning.) THE BARRIER PERFORM A REDUCED SPEED CLOSING UNTIL THE LIMIT SWITCH...
  • Page 10: Working Time ( Automatic )

    4.WORKING TIME PROFESSIONAL learning Slow down is setted by the operator RELEASE THE BARRIER AND MOVE THE ARM IN 45° PRESS AND KEEP PRESSED P1\SET BUTTON FOR 5 SECONDS THE YELLOW LED START BLINKING RELEASE THE BUTTON IN 3 SECONDS PRESS AGAIN THE BUTTON P2\RAD THE BARRIER PERFORM A BRIEF REDUCED SPEED OPENING (If motor turns in reverse invert wires and start procedure again from the begnning.) THE BARRIER PERFORM A REDUCED SPEED CLOSING UNTIL THE LIMIT SWITCH...
  • Page 11: Remote Controls

    5. REMOTE CONTROLS MEMORISE ONE REMOTE CONTROL PRESS THE BUTTON P2 ON THE BOARD THE RED LED LIGHTS UP PRESS THE DESIRED BUTTON ON THE REMOTE CONTROL RED LED PERFORMS 4 FLASHES TO INDICATE THAT THE REMOTE IS MEMORISED RED LED BECOME RED MEMORISE ALL THE REMOTE CONTROLS BY FOLLOWING ISTRUCTIONS FROM THE POINT 3 PRESS P2 FOR 2 SECONDS 5.
  • Page 12: Trimmers And Adjustments

    6. TRIMMERS AND ADJUSTMENTS TRIMMER “FOR” - MOTOR SPEED Trimmer “FOR” adjusts the voltage applied to the motors during operations, which means adjusting the speed of the motors. With the trimmer turned fully counter-clockwise the speed of the motor if 50% of the maximum speed.
  • Page 13: Dip-Switches

    7. DIP-SWITCHES FIRE ALARM ON THE CLAMP 12-13 FIRE ALARM DISABLED DO NOT TOUCH – MANUFACTURER SETTINGS DO NOT TOUCH – MANUFACTURER SETTINGS PRESSURE SAFETY DEVICE TYPE 8K2 DETENCTION PRESSURE SAFETY DEVICE NC DETENCTION OPEN BUTTON – CLOSE BUTTON START ON CLAMP 16/17 - STOP ON CLAMP 17/18 MOTOR ENCODER ACTIVATED ( IF PRESENT ) MOTOR ENCODER DISABLED STEP BY STEP MODE...
  • Page 14: External Boards

    8. EXTERNAL BOARDS BACKUP MEMORY Inside there are all remote controls code and working time. Everytime one new remote control is memorized, automatically it is trasnfered to the backup memory TRANSFER ALL DATA FROM THE BACKUP MEMORY . Remove power supply .
  • Page 15 8. EXTERNAL BOARDS LIGHTS BOARD - 24 VDC LED FOR ARM + 24 VDC LED FOR ARM DRY CONTACT FOR GREEN LIGHT DRY CONTACT FOR GREEN LIGHT DRY CONTACT FOR RED LIGHT DRY CONTACT FOR RED LIGHT GREEN\RED LIGHTS ARE FOR TRAFFIC LIGHT.
  • Page 16 SCHEDE ACCESSORI - COLLEGAMENTI 9. LEDS Yellow led SET: - flashes for 5 seconds when turned on to indicate that it is possible to enter the Professional or Simplified Learning modes. - lights up with a fixed light while Professional or Simplified Learning are carried out. - is turned off when the control unit functions normally.
  • Page 17 1. LOOP DETECTORS CONNECTIONS START P2\RAD FUSE 2A P1\SET SIRIO 4–24 V SIRIO 4–24 V 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 OPENING CLOSING SAFETY LOOP DETECTOR LOOP DETECTOR LOOP DETECTOR NORMALLY NORMALLY...
  • Page 18 ELECTRIC CONTACTS 16-17 OPENING LOOP DETETCTOR 16. OPEN ( NO ) 17. COMMON 18-17 CLOSING LOOP DETECTOR 18. CLOSE ( NO ) 17. COMMON 19-22 EMERGENCY STOP 19, STOP ( NC ) ( INSERT A JUMPER IF NOT USED ) 22.
  • Page 19 BAME s.r.l. - Via L. da Vinci, 23 - 46020 SAN GIACOMO SEGNATE (MN) - ITALY Tel. +39 0376 616 638 - Fax +39 0376 629 456 - http://www.bame.it - http://www.delma.it Unità...
  • Page 20 BAME s.r.l. - Via L. da Vinci, 23 - 46020 SAN GIACOMO SEGNATE (MN) - ITALY Tel. +39 0376 616 638 - Fax +39 0376 629 456 - http://www.bame.it - http://www.delma.it Unità locale: Via Enrico Berlinguer, 6 - 63844 GROTTAZZOLINA (FM) - ITALY...
Save PDF