The MAKESafe Power Tool Control is designed to make normal operation of the device simple
and straightforward. To operate your power tool with the MAKESafe Power Tool Control installed,
follow the procedure below:
1.
Turn on your power tool by using the green start button on the control panel.
2.
Use your power tool.
3.
Press the red stop button on the control panel to stop your tool.
4.
If the emergency stop is activated, release the emergency stop button by rotating it
gently clockwise.
Inspections & Maintenance
MAKESafe Tools recommends the following inspections:
1.
At the beginning of each shift, cycle the tool through the complete on/off cycle and
visually verify proper operation.
Problem
My tool will not start. Every time I
try to turn my tool on, the product
makes a clicking noise, and the
tool fails to start.
My tool will not start.
I don't know what's happening
and I need help.
MAKESafe Tools, Inc. | Copyright 2021 | Last Updated 1/4/22

Normal Operation

Troubleshooting

Solution
You may have engaged low voltage protection. This
can happen due to low service voltage or under-rated
conductors. Do not use this device with an extension
cord.
You may have blown the device's internal fuse.
Unplug the device from the wall and remove the cover
using a phillips screwdriver. Remove the fuse and test
for continuity. If the fuse is blown, first identify the
source of the fault. Contact MAKESafe Tools, Inc. for
fuse replacement specifications. This device does
not use a standard fuse.
Be sure to replace the cover before plugging in the
device.