CONTENTS
Item no. 11652-5-9970 · ENU · Change 230616 · Approved 2021-05-03 · Page 1 / 9
Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
3
3
4
4
4
4
5
5
5
5

1.2 Staff qualifications

7
The device may only be transported, unpacked, installed, operated,
8
maintained and otherwise used by suitably qualified, trained and
8
authorized technical staff.
8
Only authorized specialists are permitted to install the device, to carry
out a test run and to perform work on the electrical installation.
8

1.3 Basic safety rules

8
8
The safety hazards associated with the device must be assessed again
8
following installation in the final product.
The locally applicable industrial safety regulations are always to be
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M2D068-CF02-07 and is the answer not in the manual?

Questions and answers

Summary of Contents for ebm-papst M2D068-CF02-07

  • Page 1: Table Of Contents

    Operating instructions M2D068-CF02-07 ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmühle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons.
  • Page 2: Mechanical Movement

    Operating instructions M2D068-CF02-07 WARNING 1.8 Storage Live terminals and connections even with device ; Store the device, partially or fully assembled, in a dry place, switched off protected against the weather and free from vibration, in the original Electric shock packaging in a clean environment.
  • Page 3: Technical Data

    Operating instructions M2D068-CF02-07 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Cable PVC 4G 0.5 mm², 4x crimped splices Max. clearance for screw 5 mm Item no. 11652-5-9970 · ENU · Change 230616 · Approved 2021-05-03 · Page 3 / 9...
  • Page 4: Nominal Data

    With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load cycles. If you have special questions, consult ebm-papst for support. ; Use the device in accordance with its degree of protection.
  • Page 5: Connection And Startup

    Operating instructions M2D068-CF02-07 4. CONNECTION AND STARTUP 4.2.1 Requirements ; Check whether the information on the nameplate matches the 4.1 Mechanical connection connection data. ; Before connecting the device, make sure the power supply matches WARNING the device voltage. Hot motor housing Risk of fire ;...
  • Page 6 Operating instructions M2D068-CF02-07 4.3.1 Motor protection WARNING Device has no overheating protection The device is supplied without any automatic overheating protection. The device can become hot and catch fire. → For the version without thermal overload protector, also install a suitable motor protection switch.
  • Page 7: Connection Diagram

    Operating instructions M2D068-CF02-07 4.4 Connection diagram Change of rotation direction by reversing two phases Three-phase motor Star connection black blue brown green/yellow Item no. 11652-5-9970 · ENU · Change 230616 · Approved 2021-05-03 · Page 7 / 9...
  • Page 8: Checking Connections

    This also applies for In the event of further malfunctions, contact ebm-papst. devices which have already been equipped with plugs and terminals or similar connectors by the customer.
  • Page 9 Electrolytic capacitors ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 11652-5-9970 · ENU · Change 230616 · Approved 2021-05-03 · Page 9 / 9...