B R I D G E

Connecting the Bridge

The Bridge and other Adamson devices can be connected to the AI software using standard ethernet ca-
bling (minimum Cat5e). If the network is used for control only, standard gigabit switches can be used in
addition to the switch-ports of the Bridge. A maximum of eight devices can be connected in a daisy-chain.

AVB Milan Audio

Full network connectivity, including AVB audio transport and control requires AVB enabled switches. Cur-
rentlyLuminexGigacoreSeriesandExtremeNetworksX-SeriesswitcheswithAVBlicenseweretestedto
work with Adamson AVB systems. As the Bridge includes a Milan enabled switch it can be used for smaller
AVB Milan setups without additional switches.
AdamsonAVBcomponentsuseafixedpresentationtimeof2ms(networklatency).Fromthetalkertothe
furthestlistenerinanetworkchainamaximumof2mslatencyisallowed.Ifthetotalnetworklatencyex-
ceeds2mstheaudioconnectionwillbreak.EachCS-Seriescabinetandrack-mountedequipmentincludes
switchfabricandintroducesafixedlatency.Anadditionallatencyisintroducedbythetalkerwhencreating
the stream:
CS-Seriescabinets:0.26ms
Adamson Gateway and Bridge: 0.14 ms
CreationofStreamonanAdamsonGateway:0.12ms
GigabitAVBSwitch:0.12ms
Below is an example calculation for a setup with an Adamson Gateway converting an analog signal to AVB,
connected to two Bridges. Five CS7 are connected in daisy-chain to the second Bridge:
AdamsonGateway(CreationofStream+Switch)
Bridge
Bridge
CS7

CS7

CS7

CS7

CS7
Bridge - User Manual
















Total Latency:

0.26ms
0.14 ms
0.14 ms


0.26ms


0.26ms


0.26ms


0.26ms
0.26ms
1.84 ms