6000 BTU Window Air Conditioner
8000 BTU Window Air Conditioner
10000 BTU Window Air Conditioner
12000 BTU Window Air Conditioner
NOK5W
NOK66
NOK67
NOK68
Please read the entire manual carefully
to ensure proper operation of the product.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the NOK5W and is the answer not in the manual?

Questions and answers

Summary of Contents for MasterCraft NOK5W

  • Page 1 OWNER’S MANUAL 6000 BTU Window Air Conditioner 8000 BTU Window Air Conditioner 10000 BTU Window Air Conditioner 12000 BTU Window Air Conditioner NOK5W Please read the entire manual carefully to ensure proper operation of the product. NOK66 NOK67 NOK68...
  • Page 2: Product Registration

    PROdUCT REgiSTRATiON Thank you for purchasing a Master Craft® product. The first step to protect your new product is to complete the product registration on our website: www.mcappliance.com/register. The benefits of registering your product include the following: Registering your product will allow us to contact you regarding a safety notification or product update. Registering your product will allow for more efficient warranty service processing when warranty service is required.
  • Page 3: Table Of Contents

    CONTENTS PRODUCT REGISTRATION ........2 IMPORTANT SAFETY INSTRUCTIONS .
  • Page 4: Important Safety Instructions

    iMPORTANT SAfETy iNSTRUCTiONS ExPLANATION OF SYMBOLS WARNiNg: Hazards or unsafe practices which COULd result in severe personal injury or death. CAUTiON: Hazards or unsafe practices which COULD result in minor personal injury or property damage. IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using the appliance. For household use only.
  • Page 5 21. Contact customer service or an authorized service technician for repair or maintenance of this unit. DO NOT try to take apart or repair the unit by yourself. 22. Turn off and unplug the unit if strange sounds, smells, or smoke come from it. 23.
  • Page 6: Specifications

    SPECifiCATiONS figure 1 Model MCRAC6KEWM MCRAC8KEWM MCRAC10KEWM MCRAC12KEWM Dimensions 18.5” x 15.7” x 13.4” 18.5” x 17.5” x 13.4” 19.0” x 21.5” x 14.6” 19.0” x 21.5” x 14.6” (W x D x H) 6,000 8,000 10,000 12,000 Voltage 115V / 60Hz 115V / 60Hz 115V / 60Hz 115V / 60Hz...
  • Page 7: Installation Instructions

    iNSTALLATiON iNSTRUCTiONS BEFORE YOU BEGIN iMPORTANT: Save these instructions for local inspectors use. iMPORTANT: Observe all governing codes and ordinances. NOTE TO CONSUMER: Keep these instructions for future reference. NOTE TO iNSTALLER: Be sure to leave these instructions with the Consumer. •...
  • Page 8 NOTE: Save the carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter, or when not in use. PREPARE THE WINDOW The lower sash must open sufficiently to allow a clear vertical opening of 14” (356mm) high for 6,000 -8,000 btu units, and 15-1/2”...
  • Page 9 INSTALL THE ACCORDIAN PANELS NOTE: Top rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of (5/16 ). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained. Place unit on floor, a bench or a table.
  • Page 10 NOTE: Check that the air figure 13 conditioner is tilted back about 3° to 4° down towards the outside (Figure 12). After proper installation, if condensation does not drain from the overflow drain hole during normal use, correct Window the angle of the slope. Frame Extend the side panels out against the window frame (Figure 13).
  • Page 11 INSTALL R1 HARDWARE (ONLY APPLICABLE TO ENERgY STAR MODELS) In order to minimize air leaks and ensure optimal insulation, it is necessary to install the included R1 hardware (h) to the side curtain. Follow the instructions below. After the unit is installed to the window, measure the inner width of the side curtain as shown in Figure 18.
  • Page 12 IF AC IS BLOCKED BY STORM figure 22 WINDOW Sash If a storm window prevents the air conditioner Storm window from properly fitting into the space and it frame or other cannot be removed, use a board with a obstruction width of at least 1-1/2”...
  • Page 13: Operation Instructions

    OPERATiNg iNSTRUCTiONS OPERATION OF CURRENT DEVICE The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following: Plug in the Air Conditioner. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
  • Page 14 SLEEP FEATURE Press (Sleep) button to initiate the sleep mode. The selected temperature will increase by 2°F/1 or 2°C 30 minutes after the mode is selected, then another 2°F/ 1 or 2°C after an additional 30 minutes. This new temperature will be maintained for 6 hours and then return to the original temperature setting. The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again.
  • Page 15 FOLLOW ME (Only for models with this feature) The remote control serves as a remote thermostat allowing for the precise temperature control at its location. Point the remote control towards the unit and press the Follow Me button. The remote will display the temperature at its actual location, and send a signal to the air conditioner every 3 minutes until the Follow Me button is pushed again, turning the feature off.
  • Page 16 • ONE TOUCH: Push to automatically start the COOL function with the fan set to AUTO and the temperature set to 80°F (26°C). TIMER function will be cancelled if set. (Not available on all models.) • MODE: Press to select desired operation mode. •...
  • Page 17 WARNING: • Chemical Burn Hazard. Keep batteries away from children. • This product contains a lithium button/coin cell battery. If a new or used lithium button/coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours.
  • Page 18 DIRECTIONAL AIR LOUVERS The louvers will allow you to direct the figure 27 Levers air flow Up or Down (on some models) and Left or Right. Pivot horizontal louvers until the desired Up/Down direction is obtained. Move the Levers from side to side until the desired Left/ Right direction is obtained.
  • Page 19: Care And Maintenance

    CARE ANd MAiNTENANCE CAUTiON: Clean your air conditioner regularly to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. CLEANING THE AIR FILTER The air filter should be checked at least once a figure 31 month to see if cleaning is necessary.
  • Page 20: Troubleshooting

    TROUBLESHOOTiNg Please check the following before calling for service. Problem Solution Wall plug disconnected. Push plug firmly into wall outlet. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset Air conditioner does not circuit breaker. start.
  • Page 21 Remote Sensing Remote control not within range. Place remote control within 20 feet & 180° radius of the Deactivating front of the unit. Prematurely (some Remote control signal obstructed. Remove obstruction. models) Room too cold Set temperature is too low. Increase set temperature. •...
  • Page 22: Limited Warranty

    LiMiTEd WARRANTy MC Appliance Corporation warrants each new ROOM AIR CONDITIONER to be free from defects in material and workmanship and agrees to remedy any such defect or to furnish a new part(s) (at the company’s option) for any part(s) of the unit that has failed during the warranty period.