Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read
this installation guide carefully to ensure correct use.
1. Safety Precautions
1.1
General
 Unpack and check the delivery for transportation damage. If any damage or
deformation is found, please notify the supplier.
 The supplier is not responsible for the disassembled, altered or modified device.
 Never allow fluid or any conductive particles to enter into the HMI. Otherwise,
it may damage the HMI, cause fire or malfunction.
 Only qualified personnel may install the HMI, perform maintenance and
inspection.
 The liquid crystal inside the LCD panel is a hazardous substance. If the panel
is damaged, avoid contact with the leaked liquid crystal. If the liquid crystal
spills on clothing or skin, use soap and wash off thoroughly. In case of eye
contact the liquid, hold the eye open, flush with plenty water and get medical
attention as soon as possible.
 Do not touch any terminals while the power is on. Otherwise, it may cause
injury due to electrical shock.
 Disconnect the power supply before installing the HMI, do wiring operation,
perform maintenance or inspection. Otherwise, it may cause damage or
electrical shock.
1.2
Installation
 The installation may be carried out by qualified personnel only.
 Install the HMI according to the installation procedures.
 Check the power source voltage is within the specified range and the polarity
is correct before connecting the HMI.
 Keep signal and power supply cables away from high-voltage, large-current
carrying cables.
P5150NH HMI Installation Guide
(Read these precautions before use.)
1

Advertisement

Table of Contents
loading

Summary of Contents for FATEK P5150NH

  • Page 1 P5150NH HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions (Read these precautions before use.) General  Unpack and check the delivery for transportation damage. If any damage or deformation is found, please notify the supplier.
  • Page 2 Make sure the HMI is properly grounded to prevent electrical Caution shock, fire or malfunction.  HMI unit and other equipment should have the same electrical grounding (reference voltage level), otherwise communication errors may occur. Operation  Do not use sharp objects or excessive force to press the touch screen. This may damage the touch screen.
  • Page 3: Part Names And Dimensions

    2. Part Names and Dimensions Power Indicator ① Light ② Mounting Hole HB1 PLC ③ Connector COM3/COM4 ④ Termination Switch HB1 PLC ⑤ Screw Hole Power ⑥ Connector COM3/COM4: ⑦ Pluggable Terminal Block Mini USB ⑧ Connector ⑨ USB Connector Ethernet RJ45 ⑩...
  • Page 4: Specifications

    3. Specifications Model P5150NH Control Type of item tested Operator Panel Product Description Connections to mains Permanent supply Overvoltage category Pollution degree Class III Means of Protection Operating Temp. 0~50°C Environmental conditions Storage Temp. -20 ~ 60 ℃ UL 61010-1...
  • Page 5: Unpacking The Unit

    4. Unpacking the Unit FATEK PLC FATEK HMI x1 Hook and Screw x10 Connector x1 Pluggable Terminal A4 Double-sided Installation Guide x1 Power Connector x1 Block x1 5. Installation Procedures  Push the HMI into the cutout until the waterproof ring contacts the plate.
  • Page 6: Power Connection

    7. Termination Switch  P5150NH HMI has a built-in termination resistor switch. To enable or disable the termination resistor please follow the configuration shown in the table below. The termination switch is for COM3 [RS-422 / RS- 485] and COM4 [RS-485].
  • Page 7 8. Pin-out of COM Ports DB-9 Male Connector COM1 PIN# [RS-232] *1 NC: No Connection Pluggable Terminal Block COM3 COM3 COM4 PIN# [RS-422] [RS-485] [RS-485] DATA+ DATA- DATA+ DATA-...
  • Page 8 9. PLC Extension Tips  For compact size and saving space, using FATEK HB1 main units + B1 extension modules is recommended.  To connect FATEK PLC main unit, first use the FATEK PLC connector to connect the main unit and then insert into the HB1 connector hole on the back cover of the HMI to complete the connection.

Table of Contents