supplied with the probe.
4. Tap the start pad or set the timer and with the magnetron oscillating,
measure the leakage by holding the probe perpendicular to the surface
being measured.
3.2.1. Measurement with the outer panel removed.
Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed
and after all necessary components are replaced or adjusted. Special care should be taken in
measuring around the magnetron.
3.2.2. Measurements with a fully assembled oven.
After all components, including outer panel are fully assembled, measure for radiation leakage around
the door periphery, the door viewing window, the exhaust opening, control panel and air inlet openings.

3.3. Record keeping and notification after measurement

- After any adjustment or repair to a microwave oven, a leakage reading
must be taken. Record this leakage reading on the repair ticket even if it
is zero.
A copy of this repair ticket and the microwave leakage reading should
be kept by repair facility.
- Should the radiation leakage be more than 2 mW/cm
Canada) after determining that all parts are in good condition,
functioning properly, and genuine replacement parts as listed in this
manual have been used, immediately notify PASC, PSC or PCI.
3.4. At least once a year, have the radiation monitor checked for
calibration by its manufacturer.

4. SIMPLE WAY OF H.V. INVERTER/MAGNETRON

11
(1mW/cm for
2