Download Print this page

Napoleon BKE Installation Instructions

Blower kit e36/e42

Advertisement

Available languages

Available languages

Quick Links

Blower Kit Installation Instructions (E36 / E42)
WARNING
!
• Do not touch safety screen until cooled.
• Allow safety screen to cool completely before any maintenance, as it will remain hot after appliance is no
longer operating.
• Ensure the appliance is completely cool before starting installation.
• To avoid danger of suffocation keep the packaging bag away from babies and children. Do not use in cribs,
bed, carriages, or play pens. This bag is not a toy. Knot before throwing away.
A.
Remove the screen by lifting it up and off of the appliance.
B.
Remove the door from the appliance by releasing the door latches.
C.
It may be necessary to move the control module aside during blower installation. (Electronic Only)
D.
Attach the two 1/4" connectors (black and white) from the wire harness to the thermal disc.
E.
Attach the two 1/4" connectors (black and red) from the wire harness to the blower.
F.
Pivot the blower into the bottom of the appliance and align clips with slots then push down to mount, see
Figures 1 and 2.
NOTE: WITH THE WIRE CLIP SUPPLIED, ENSURE ALL WIRES REMAIN CLEAR OF THE BLOWER.
FIGURE 1
MOUNTING LOCATION
G.
Place the control module back into its original position. Ensure the transformer is plugged into the outlet of the
electrical box.
H.
Plug the connector from the variable speed switch to the matching connection on the wire harness.
I.
Install the variable speed switch (VSS) onto the existing mounting bracket.
J.
The VSS will need to be disassembled to secure to the VSS bracket for installation. Place the VSS through the
mounting bracket using the lock washer to secure it in place. Take the variable speed switch knob and install
into position (Figure 3).
FIGURE 3
K.
Where applicable, bend the thermal disc bracket 90 degrees and secure it to the fi rebox mounting tab using
the two screws supplied (Figure 4). Ensure that the thermal disc is in contact with the fi rebox base and that
the wire harness is properly attached.
L.
Plug the power cord from the blower into the electrical box.
NOTE: The blower is thermally activated, so when it is turned on, it will automatically
start approximately 15 minutes after lighting the appliance and will run for approximately
30 minutes after the appliance has been turned off.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada •
NOTE: VSS mounting bracket hidden for clarity purposes.
BKE
FIGURE 2
FIGURE 4
1(866)820-8686
REAR VIEW
www.napoleon.com
W415-2998 / 02.09.21

Advertisement

loading

Summary of Contents for Napoleon BKE

  • Page 1 15 minutes after lighting the appliance and will run for approximately 30 minutes after the appliance has been turned off. W415-2998 / 02.09.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 2 NOTE: La souffl erie est actionnée par la chaleur. Lorsqu’elle est mise sous tension, elle se met automatiquement en marche environ 15 minutes après l’allumage de l’appareil et fonctionnera environ 30 après l’arrêt de l’appareil. W415-2998 / 02.09.21 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...

This manual is also suitable for: