  • Page 1 Installation and Operation Manual 800 SERIES TURBO GAS FRYERS Models: TGF-1M/400L TGF-24ML...
  • Page 2 Manufacturer: Goldstein Eswood Commercial Cooking PTY LTD For inquiries please call your nearest state branch or visit our website. New South Wales – Head Office Address: 211 – 217 Woodpark Road, Smithfield NSW 2164 Phone: +61 (02) 9604 7333 Fax:...
  • Page 3: Table Of Contents

    Contents Contents .......................... 3 ONTENTS ........................4 NTRODUCTION ........................5 PECIFICATIONS ........................6 IMENSIONS ........................8 NSTALLATION ........................11 PERATION ..................... 13 LEANING AND AINTENANCE ......................15 ROUBLE HOOTING ......................16 ONVERSION 10. W ......................17 IRING IAGRAM 11. S ........................
  • Page 4: Introduction

    This appliance is intended for professional use and is only to be used by trained, qualified personnel. Installation, maintenance and repairs should be performed by an authorized Goldstein Eswood service agent or other qualified personnel. Installation, maintenance or repairs by an unauthorized and unqualified personnel will void the warranty.
  • Page 5: Specifications

    Specifications Specifications 3.1 General Description A commercial, heavy duty gas fryer with fast recovery and high energy efficiency. The tube tunnel burners are automatically controlled by a gas-powered valve with an inbuilt regulator. The tank and body is made from high grade stainless steel for lasting durability and finish. 3.2 Model numbers covered in this manual: ▪...
  • Page 6: Dimensions

    Dimensions Dimensions 4.1 TGF-1M/400L Note: Dimensions may change without notice in accordance with product design and development TGF SERIES FRYERS...
  • Page 7 Dimensions 4.2 TGF-24ML Note: Dimensions may change without notice in accordance with product design and development TGF SERIES FRYERS...
  • Page 8: Installation

    Installation Installation Goldstein 800 Series Turbo Fryers are designed to give long and satisfactory service and incorporate the best possible materials and workmanship. Proper installation and preventative maintenance are vital for optimum performance and efficiency. WARNING This appliance must be installed by authorized personnel and in accordance with AS5601 &...
  • Page 9 Installation 5.4 Gas Connection This appliance has been tested and pre-set before leaving the factory, however minor adjustments may be necessary to suit the gas supply pressure. Correct operation of the appliance must be tested as part of the installation procedure. Note: Gas fitting must only be carried out by an authorised and qualified person.
  • Page 10 Installation 5.5 Commissioning Once the appliance has been installed always ensure its functions are operating as per the following check list. Refer to Operation in section 6 for further details on how to operate each control. 1. Remove any plastic coating from steel panels. 2.
  • Page 11: Operation

    Operation 6.1 Operational Controls Flame failure protection and permanent pilots are fitted as standard on all Goldstein fryers as required by local regulations and safety to the operator. If the pilot flame goes out, the flame failure protection will shut off the gas to the burner. The permanent pilot allows for the appliance to go on stand-by and the operator to continuously re-light the main burners without re-ignition.
  • Page 12 Operation 6.3 Filling the Tank with Liquid Shortening 1. Ensure that the oil drain valve is closed and the tank is free of any residual moisture. 2. Place the scrap arrestor in the tank as shown. 3. Fill the fryer tank to the indicated level. It is recommended to fill the oil slightly lower than desired.
  • Page 13: Cleaning And Maintenance

    Cleaning and Maintenance Cleaning and Maintenance 7.1 General Build-up of grease, fat and carbon will impede effective heat transfer from the heat source to the cooking medium. Keeping the fryer clean will ensure it operates correctly and efficiently. CAUTION Do not use steel wool, abrasive materials or caustic detergents on this appliance. Do not use metal knives, spatulas or any other metal utensils to scrape the fryer tank or stainless steel surfaces.
  • Page 14 Incorporating a regular maintenance schedule will optimise and keep services running efficiently. Goldstein can provide an MIS (Machine Inspection Service) that delivers regular inspection and maintenance to reduce problems before they occur. For more information or to setup an MIS, please contact the nearest Goldstein branch.
  • Page 15: Trouble-Shooting

    Gas Conversions Trouble-Shooting Please refer to the following guide as reference to diagnose and repair some of the more common problems encountered. Should a problem not listed arise, or in doubt, please contact Goldstein or an authorised service agent. Fault...
  • Page 16: Gas Conversion

    Gas Conversion Gas Conversion WARNING Gas conversion procedures should only be performed by an authorized Goldstein Eswood service agent or qualified personnel. Unauthorized and unqualified personnel will void the warranty. Gas isolator MUST be turned off before commencing any service work.
  • Page 17: Wiring Diagram

    Wiring Diagrams Wiring Diagram TGF SERIES FRYERS...
  • Page 18: Spare Parts

    Spare Parts Spare Parts 11.1 Parts Diagram – All Models TGF SERIES FRYERS...
  • Page 19 Spare Parts 11.2 Parts List ITEM NO. PART NUMBER DESCRIPTION GBNAS000 BURNER GIJSF150 1.50mm LPG INJECTOR GIJSF270 2.70mm NG INJECTOR GPIB0005 PILOT BODY GPG00900 900mm POWER GENRATOR STG00A11 TUNNEL DISPENSER ASSEMBLY MKNPLFR1 KNOB GPU00001 LPG PILOT SPUD GPU00002 NG PILOT SPUD MTH20205 THERMOSTAT MKNEP001...
  • Page 20 Spare Parts ITEM NO. PART NUMBER DESCRIPTION GNIC0001 1/8" TEST NIPPLE MKNPLFRP KNOB GET00005 CERAMIC ELECTRODE MSP00009 SPRING & CIRCLIP FOR MKNPLFRP KNOB ESP00016 SCARIO ELEC BOX STG00A12 BOTTOM HINGE EPR00100 4mm SIT891 PROBE GCU00008 WR CONTROL FOR GAS ELECTRIC DOOR ASSY DOOR ASSY TGF1M400 TANK 12”...
  • Page 21: Warranty

    Goldstein Eswood Commercial Cooking Pty Ltd. Warranty Terms GOLDSTEIN ESWOOD COMMERCIAL COOKING PTY LTD. (hereafter “GECC”) warrants that all products supplied by GECC (hereafter “product/s”) are free of defects in material and workmanship for a period of 12 months from the date of purchase.
  • Page 22 Warranty This warranty does not apply if a defect arises from any of the following: • Improper installation or commissioning of the products. • Installation of the products not performed by a licenced installer. Proof of licence number may be required by GECC at time of placing the warranty claim.