Using EWS to control wireless Access Point in High Density area such
as Auditorium with 320 seats by using Band Steering, Client
limitation and traffic shaping. Distributing maximum 54 wireless
client to each AP
Calculations:
 Total Bandwidth : 20M
 No. of AP : 6
 Bandwidth allocated per AP: 3MB
 Client allocated per AP: 54
 Client allocated per radio band: 27
High Density Wireless Network