Installation Instructions Compact 16-point 24V dc Sink/Source High-speed Input Module Catalog Number 1769-IQ16F Use this document as a guide when installing a Compact™ 16-point 24V dc sink/source high-speed input module. Topic Page Important User Information Module Description Module Installation Mounting Expansion I/O...
Compact 16-point 24V dc Sink/Source High-speed Input Module Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of these products must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards.
IN 14 COM 2 Ensure Adjacent Bus Lever is Unlatched/Latched Before/After Removing/Inserting Module nameplate label 1769-IQ16 1769-IQ16F upper tongue-and-groove slots lower tongue-and-groove slots upper DIN rail latch lower DIN rail latch write-on label (user ID tag) removable terminal block (RTB)
Compact 16-point 24V dc Sink/Source High-speed Input Module Module Installation Compact I/O is suitable for use in an industrial environment when installed in accordance with these instructions. Specifically, this equipment is intended for use in clean, dry environments (Pollution degree 2 ) and to circuits not exceeding Over Voltage Category II (IEC 60664-1).
Page 5
Compact 16-point 24V dc Sink/Source High-speed Input Module System Assembly The module can be attached to the controller or an adjacent I/O module before or after mounting. For mounting instructions, see Panel Mounting on page 6, or DIN Rail Mounting on page 8. To work with a system that is already mounted, see Replacing a Single Module within a System on page 8.
Compact 16-point 24V dc Sink/Source High-speed Input Module 7. Attach an end cap terminator (5) to the last module in the system by using the tongue-and-groove slots as before. 8. Lock the end cap bus terminator (6). A 1769-ECR or 1769-ECL right or left end cap must be used to IMPORTANT terminate the end of the serial communication bus.
Page 7
Compact 16-point 24V dc Sink/Source High-speed Input Module Panel Mounting Using the Dimensional Template For more than 2 modules: (number of modules - 1) X 35 mm (1.38 in.) 28.5 Refer to host controller documentation for this dimension. (1.12) (1.38) (5.197) 122.6±0.2 NOTE: All dimensions...
Compact 16-point 24V dc Sink/Source High-speed Input Module DIN Rail Mounting The module can be mounted using the following DIN rails: 35 x 7.5 mm (EN 50 022 - 35 x 7.5) or 35 x 15 mm (EN 50 022 - 35 x 15). Before mounting the module on a DIN rail, close the DIN rail latches.
Refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley publication 1770-4.1, for additional information. Input Wiring Basic wiring of input devices to the 1769-IQ16F is shown below. Miswiring of the module to an AC power source will damage the ATTENTION module.
Page 10
Compact 16-point 24V dc Sink/Source High-speed Input Module A removable, write-on label is provided with the module. Remove the label from the door, mark the identification of each terminal with permanent ink, and slide the label back into the door. Your markings (ID tag) will be visible when the module door is closed.
Page 11
Compact 16-point 24V dc Sink/Source High-speed Input Module 3. Tighten the terminal screw making sure the pressure plate secures the wire. Recommended torque when tightening terminal screws is 0.68 Nm (6 in-lbs). If you need to remove the finger-safe cover, insert a screw driver into one of the square, wiring holes and gently pry the cover off.
Compact 16-point 24V dc Sink/Source High-speed Input Module 1769-IQ16F Configuration File The read/writable configuration data file allows the setup of the digital filter settings for each of the two input groups. Group 0 is inputs 0 - 7, Group 1 is inputs 8 - 15.
Compact 16-point 24V dc Sink/Source High-speed Input Module Specifications General Specifications Specification Value Dimensions 118 mm (height) x 87 mm (depth) x 35 mm (width) height including mounting tabs is 138 mm 4.65 in. (height) x 3.43 in (depth) x 1.38 in (width) height including mounting tabs is 5.43 in.
Page 14
Compact 16-point 24V dc Sink/Source High-speed Input Module Input Specifications Specification 1769-IQ16F Voltage Category 24V dc (sink/source Operating Voltage Range 10 to 30V dc at 30°C (86°F) 10 to 26.4V dc at 60°C (140°F) Number of Inputs Bus Current Draw (max.) 110 mA at 5V dc (0.55W)
Compact 16-point 24V dc Sink/Source High-speed Input Module Hazardous Location Considerations This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only. The following ATTENTION statement applies to use in hazardous locations. EXPLOSION HAZARD ATTENTION –...
For More Information Refer to this Document Pub. No. a more detailed description of how to install MicroLogix 1200 and MicroLogix 1764-RM001B-US-P and use your Compact I/O with MicroLogix 1500 Programmable Controllers User 1200 & 1500 programmable controller Manual a more detailed description of how to install 1769-ADN DeviceNet Adapter User 1769-UM001A-US-P and use your Compact I/O with the...
Need help?
Do you have a question about the 1769-IQ16F and is the answer not in the manual?
Questions and answers