MOUNTING ENCLOSURE GUIDELINES

Separation panel
Gas bottle venting slots
Enclosure construction
All materials used for the construction of the enclosure
and gas bottle compartment must be non-combustible
A 40mm min. gap between the enclosure and rear wall
is required. This allows for venting of the gas bottle
compartment. Vents should also be positioned at the
front of the enclosure
The cutout size specified above allows for a 20mm gap
between the bottom of the barbecue and the separation
panel as well as a 20mm gap between the back of the
barbecue and benchtop. These gaps are necessary for
maintaining air flow around the barbecue
828mm 4 burner
100mm
min.
1006mm 5 burner
Rear wall/splashback to be
non-combustible material
Gas bottle compartment ventilation requirements
AS5601 ventilation requirements for 9kg cylinder storage are:
630mm min.
540mm
40mm
gap min.
Where of sheet metal or similar impervious construction
there shall be ventilation openings at the top and bottom
of the enclosure or recess, each opening providing a free
2
area of at least 200cm
for every cylinder enclosed
For LPG installations having enclosed cabinetry below
the separation panel that does not contain a gas bottle,
low level venting must be installed. This is to allow
the gas which is heavier than air to escape from the
enclosure in the situation where there may be a leak.
A minimum opening of 200cm
2
MOUNTING ENCLOSURE GUIDELINES
Gas bottle
venting slots
is required