Model Names; Disclaimer And Safety; Warning Regarding Medical Use - Agilent Technologies Acqiris DP105 User Manual

Agilent acqiris 8-bit digitizers
Hide thumbs Also See for Acqiris DP105:
Table of Contents

Advertisement

1.4.

Model Names

Agilent Technologies Inc. acquired Acqiris SA and its product lines in December 2006. Use the tables below to cross
reference new Agilent numbers with options to the legacy model name. The legacy model name is what is used in the
Acqiris applications and the API.
Agilent Model Number
U1061A-001-F50
U1061A-001-FHZ
U1061A-002-F50
U1061A-002-FHZ
U1063A-001
U1063A-002
U1064A-001-F50
U1064A-001-FHZ
U1064A-002-F50
U1064A-002-FHZ
U1064A-004-F50
U1064A-004-FHZ
U1067A
U1067A
U1068A
U1068A
U1069A
U1069A
U1069A
U1071A-001-F50
U1071A-001-FHZ
U1071A-002-F50
U1071A-002-FHZ
U1071A-004-F50
U1071A-004-FHZ
U1091A
U1091A
U1091A
1.5.

Disclaimer and Safety

The DP Series PCI digitizer cards have been designed to operate in a standard PCI slot found inside most personal
computers. The model DC Series CompactPCI/PXI digitizers have been designed to operate inside a
CompactPCI/PXI crate. The crate provides the modules with all needed power. Agilent does not recommend
operation of the DC Series modules outside of a CompactPCI/PXI crate.
CAUTION:
Do not exceed the maximum input voltage rating! The maximum input voltage for 50
impedance is
for the DC2x1A/AR models where it is
1.6.

Warning Regarding Medical Use

The Digitizer cards are not designed with components and testing procedures that would ensure a level of reliability
suitable for use in treatment and diagnosis of humans. Applications of these cards involving medical or clinical
treatment can create a potential for accidental injury caused by product failure, or by errors on the part of the user.
These cards are not intended to be a substitute for any form of established process or equipment used to monitor or
safeguard human health and safety in medical treatment.
WARNING:
The modules discussed in this manual have not been designed for making direct measurements
on the human body. Users who connect an Acqiris module to a human body do so at their own
risk.
User Manual: Agilent Acqiris 8-bit Digitizers
Acqiris Model Name
DC135
DC13HZ
DC140
DC140HZ
DC265
DC270
DC211
DC211A
DC241
DC241A
DC271
DC271A
DP110
DP105
DP210
DP211
DP240
DP235
DP214
DP1400
U1071AHZ1
U1071A002
U1071AHZ2
U1071A004
U1071AHZ4
DC110
DP106
DP212
±
5 V. The maximum input for 1 M
Agilent Model Number
U1091A
U1061A-001-F50
U1061A-001-FHZ
U1061A-002-F50
U1061A-002-FHZ
U1064A-001-F50
U1064A-001-FHZ
U1064A-002-F50
U1064A-002-FHZ
U1063A-001
U1063A-002
U1064A-004-F50
U1064A-004-FHZ
U1067A
U1091A
U1067A
U1068A
U1068A
U1091A
U1069A
U1069A
U1069A
U1071A
U1071A-002-F50
U1071A-004-F50
U1071A-001-FHZ
U1071A-002-FHZ
U1071A-004-FHZ
Ω
input impedance is
±
300 V (dc + ac) .
Acqiris Model Name
DC110
DC135
DC135HZ
DC140
DC140HZ
DC211
DC211A
DC241
DC241A
DC265
DC270
DC271
DC271A
DP105
DP106
DP110
DP210
DP211
DP212
DP214
DP235
DP240
DP1400
U1071A002
U1071A004
U1071AHZ1
U1071AHZ2
U1071AHZ4
Ω
input
±
100 V (dc + ac) except