CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
ADANGER
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS
OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON
MONOXIDE POISONING AND/ OR ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE
OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS
MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID
IAWARNINGI
�-
---�-COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR
CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY
THESE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY
CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS.
Larson Electronics, LLC
Forced Air Heater - 120V - Natural Gas - 435
CFM, 150,000 BTUs - 10' Hose/Regulator
Instruction Manual
Phone: (800) 369-6671
Fax: (903) 498-3364
GAU-NFA-HH-150K
www.larsonelectronics.com
1 of 12

Advertisement

loading

Summary of Contents for Larson Electronics GAU-NFA-HH-150K

  • Page 1 THESE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 2 ANSI Z83.7-2011/CSA 2.14-2011. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gasses and heating products for specific uses. Your local authority can advise you about these. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 3 Sides Front Rear every 100,000 Btu / Hr heater rating. Refer to 24 in. 36 in. 72 in. 24 in. "Ventilation" on page 7 for further instructions. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 3 of 12...
  • Page 4 A C AU T ION I ��:s��:� :�g�f :t��;�pplied 2. �����: :ij items from carton with the heate must be used without alte ation. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 4 of 12...
  • Page 5 Max Outlet Temp ( ° Volts: AC/Hz 120V~60Hz Amps Specifications subject to change without notice. Features Guard Power Cord T hermostat Knob Power Switch Base Figure 2 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 5 of 12...
  • Page 6 6. Slowly open valve at Natural Gas supply. 7. Check for leaks at all connections. Figure 3 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 6 of 12...
  • Page 7 N OTE: Heater surface temperature must be cold before initiating service, cleaning or storage. Lower Temperature Higher Temperature Figure 4 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 7 of 12...
  • Page 8 B 149 .1. The plastic valve plug or valve cover Re-gap the terminals to 0.160" (4mm) supplied with the supply line must be re-installed on the valve to protect the fitting from damage. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 9 GAU-NFA-HH-150K Wiring Diagram White Black Black Green Black Spark Black White Earth ,..__..___.1==>-----tt-J Module (1.) ."t: hermostat (1.) Thermal Switch Solenoid Valve (1.) Green Earth Figure 5 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 9 of 12...
  • Page 10 Heater stops running and behind heater clear of by itself. obstructions. Damaged control valve. Replace control valve. Dust or Debris accumulated Clean inside of heater. in heater. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 10 of 12...
  • Page 11 22 - � � - 2 0 • ffhi� 3 6 �- 21 - l � � � 31 2 6 ; 25 � • • • Figure 6 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 11 of 12...
  • Page 12 Thermal Switch cable Middle Connector Regulator Assembly (Integrated) Nozzle Cap Sensor Plug Bracket Assembly Solenoid Cable Solenoid Valve Outlet Connector Power Switch hex Bolt Thermostat Thermostat Knob Sensor Cable Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 12 of 12...