Larson Electronics GAU-KFA-PH-600K-TST Instruction Manual

Cart mounted forced air heater

Advertisement

Quick Links

120V - Kerosene/Diesel - 3000 CFM, 600000 BTUs - 40 Gal Tank - Blue
Thank you for your purchase of the Larson Electronics GAU-KFA-PH-600K-TST.
WARNING:
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF FIXTURE'S ELECTRICAL
SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE FIXTURE'S RATED VOLTAGE.
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS. SUITABLE FOR DAMP LOCATIONS.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE. THE GAU-KFA-PH-600K-TST MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL
CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS
PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET,
CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE.
WARNING: MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE
INSTALLATION OR PERFORMING ANY MAINTENANCE.
RISK OF FIRE/ELECTRIC SHOCK –
RISK OF PERSONAL INJURY –
RISK OF BURN –
ALLOW FIXTURE TO COOL BEFORE SERVICING.
WARNING:
USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE.
CORD IS INTENDED TO ALLOW OPERATORS TO EXTEND POWER TO EQUIPMENT WHEN STATIONARY OUTLETS ARE NOT
READILY AVAILABLE.
IMPROPER USE OF THIS CORD, PLUG, AND RECEPTACLE CAN LEAD TO SERIOUS INJURIES OR DEATH TO
PERSONNEL.
PERIODIC INSPECTION OF THE CORD IS NECESSARY.
THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND,
THE CORD MUST BE REPLACED BEFORE RESUMING USE.
ADANGER
of fire, explosion,
burn,asphyxiation,
Only persons who can follow and understand these instructions should use or service this
heater. If you need heater information such as an instruction manual, labels, etcetera,
contact the manufacturer.
ADANGER
under construction, alteration or repair.
Larson Electronics, LLC
Cart Mounted Forced Air Heater
Instruction Manual
DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.
FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY.
GENERAL HAZARD WARNING: Be sure to comply with the
instructions and warnings provided with this heater, or death,
serious bodily
injury
and carbon monoxide poisoning can result.
Not for use in residential living areas or in non-adequately ventilated
enclosed spaces. For outdoor use. Indoor use permitted for: The
temporary heating of adequately ventilated buildiogs or structures
Phone: (800) 369-6671
and property loss, damage from the hazards
Fax: (903) 498-3364
GAU-KFA-PH-600K-TST
www.larsonelectronics.com
THIS LINE
1 of 16

Advertisement

Table of Contents
loading

Summary of Contents for Larson Electronics GAU-KFA-PH-600K-TST

  • Page 1 IMPORTANT READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. THE GAU-KFA-PH-600K-TST MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY. WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS PRODUCT.
  • Page 2 GAU-KFA-PH-600K-TST The Larson Electronics GAU-KFA-PH-600K-TST Cart Mounted Forced Air Heater is a powerful heating solution for indoor facilities. This kerosene/diesel unit provides 3,000 CFM of air flow and 600,000 BTUs. Equipped with a 40-gallon fuel tank, the portable heater is mounted on a cart and comes with real-time gauges and a 6"...
  • Page 3: Table Of Contents

    6 months. Nl�:VER use fuels such as gasoline, benzene, paint thinners, crankcase drainings, or other oil compounds in this heater (RISK OF FIRE OR EXPLOSION). Larson Electronics, LLC 3 of 16 Phone: (800) 369-6671 Fax: (903) 498-3364...
  • Page 4: Safety Information

    4 ft. (125 cm) 10 ft. (305 cm) Front Features Handle Frame Front Handle Front Shell Rear Handle Lower Shell Fan Guard Control Panel Figure 1. Features of Model GAU-KFA-PH-600K-TST Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 4 of 16...
  • Page 5: Unpacking

    Handle Frame Fan Guard � Wheel Support Frame _ _ ---' Wheel Tube Valve Flat Washer (L) Flat Washer (S) Cotter Pin Figure 2. Assembly of Model GAU-KFA-PH-600K-TST Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 5 of 16...
  • Page 6 '--· _______ __,_ 2. Place flat washers (L) and cotter pins on axle ends and bend cotter pins with long nose pliers to secure. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 7: Operation

    Once the temperature falls start. Push the up and down arrow keys on the control panel to below the reset temperature, you will be ale to start your heater. adjust the thermostat settings. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 8 Figure 5. Control Panel lower than air around heater. Heater will cycle back on if air temperature around heater matches thermostat setting. Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 8 of 16...
  • Page 9 Insert seal cap fully into head hole so that cap flange is flush to head flange. See Figure 6. Drain Bolt (Bottom-Fron Fuel Tank) Figure 6. Drain Bolt Reinstall Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 9 of 16...
  • Page 10: Maintenance

    6. Attach spark plug wire to spark plug. inch-pounds). 7. Reinstall upper shell. 11. Reinstall spark plug in burner head. 12. Attach burner head to combustion chamber. Larson Electronics, LLC 10 of 16 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 11 3. Wash fuel filter with clean kerosene. 4. Replace fuel filter on fuel tank. Pump pressure gauge is not supplied. 5. Replace fuel cap on fuel tank. Larson Electronics, LLC 11 of 16 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 12: Wiring Diagram

    OPERATION CHECK-UP POWER �[m:J]@Jl � TEW. U P � BLACK FUSE 10A'250VAC BLACK BLACK GRAY PHOTOCELL AC 120V 60Hz WHITE GRAY GRAY EARTH BROWN BROWN GREEN GREEN Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 12 of 16...
  • Page 13: Exploded View

    GAU-KFA-PH-600K-TST Exploded View Larson Electronics, LLC 13 of 16 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 14: Parts List

    GAU-KFA-PH-600K-TST Parts List GAU-KFA-PH-600K-TST PCB Assembly Fuel 70-027 -0800 Cap Assembly 70-006-0200 Pneumatic Wheel 70-041-0110 Photocell 70-016-0150 Nozzle 70-015-0750 Fan Motor Assembly 70-021-0800 Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 14 of 16...
  • Page 15: Troubleshooting Guide

    - Align the red mark between the air - Low heat output screw and pump body 2. Power failure Power failure - No power supply to heater - Check / replace fuse Larson Electronics, LLC 15 of 16 Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 16 Larson Electronics. THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.

Table of Contents