SP50
OS50
Submersible Effluent Pump
NOTE! To the installer: Please make sure you
provide this manual to the owner of the pumping
equip ment or to the responsible party who
maintains the system.

General Information

Thank you for purchasing your StormPro™ pump.
To help ensure years of trouble-free op er a tion,
please read the fol low ing manual carefully.

Before Operation:

Read the following in struc tions care ful ly.
Reasonable care and safe meth ods should be
practiced. Check local codes and requirements
before installation. Only qualified electricians
should make the installations.
Attention:
This manual contains important information for
the safe use of this product. Read this manual
completely before using this product and refer to
OPERATION MANUAL
Dated: 08/04/10
Supersedes: None
Document No.: 23833A669
it often for con tin ued safe product use. DO NOT
THROW AWAY OR LOSE THIS MAN U AL. Keep it
in a safe place so that you may refer to it often.
Servicing should be performed only by a
knowledgeable pump service contractor or
authorized service stations.
WArning: Before handling these pumps and
controls, always disconnect the power first. Do
not smoke or use sparkable electrical devices
or flames in a septic (gaseous) or possible
septic sump.
Pump Warning
To reduce risk of electrical shock:
1. Risk of Electrical Shock: This pump has not
been in ves ti gat ed for use in swimming pool &
marine areas.
2. Risk of Electrical Shock: Connect only to a
properly ground ed receptacle.
Septic tank is to be vented in ac cor dance with local
plumbing codes.
Do not smoke or use sparkable electrical devices
or flame in a septic (gaseous) or possible septic
sump.
If it is necessary to enter sump, then (1) provide
proper safety precautions per OSHA re quire ments
and (2) do not enter sump until these precautions
are strictly adhered to.
Do not install pump in location clas si fied as
hazardous per NEC, ANSI/NFPA 70-2001.
Failure to heed above cautions could result in
injury or death.

Installation Instructions

These important instructions must be followed for
satisfactory performance of your pump:
1. Provide proper sump (recommended minimum
sump diameter is 18").
2. Do not set pump directly on the bottom of
the sump if it is not solid. Raise the pump by
placing bricks or concrete blocks underneath it.
Page 1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SP50 and is the answer not in the manual?

Questions and answers

Summary of Contents for StormPro SP50

  • Page 1 General Information Do not install pump in location clas si fied as Thank you for purchasing your StormPro™ pump. hazardous per NEC, ANSI/NFPA 70-2001. To help ensure years of trouble-free op er a tion, please read the fol low ing manual carefully.
  • Page 2 OPERATION MANUAL Dated: 08/04/10 SP50 OS50 Supersedes: None Submersible Effluent Pump Document No.: 23833A669 Page 2 of 4 3. Make sure sump is free of string, cloth, nails, 9. In applications where the pump may sit idle gravel, etc. before installing pump.
  • Page 3 OPERATION MANUAL Dated: 08/04/10 SP50 OS50 Supersedes: None Submersible Effluent Pump Document No.: 23833A669 Page 3 of 4 Performance CAPACITY–U.S. G.P.M. Pump Notes...
  • Page 4 Your only remedy, and StormPro's only duty, is that StormPro repair or replace defective products (at StormPro choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered.

This manual is also suitable for:

Os50

Table of Contents