StormPro 2100DC Operation Manual

StormPro 2100DC Operation Manual

Heavy duty 12v dc pump

Advertisement

Quick Links

StormPro
2100DC
®
Heavy Duty 12V DC Pump
S
I
afety
nStructIonS
Read and save these instructions. This manual
contains important instructions. Failure to heed safety
instructions and warnings could result in injury or
death.
Read all the instructions before installing or using
the StormPro
2100DC. Always disconnect batteries
®
and disconnect StormPro
power source before storing, handling, or making any
adjustments to the unit.
Use StormPro
2100DC only as described in this
®
manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury
to persons.
CAUTION: Do not sit or stand on StormPro
2100DC. Keep children away.
CAUTION: Do not place objects on Stormpro
2100-DC or allow vents to become blocked.
CAUTION: Do not smoke, use sparkable
electrical devices, or open flame when
working on this unit!
CAUTION: Do not install StormPro
in locations classified as hazardous per
N.E.C., ANSIINFPA 70 - 1984.
2100DC from the AC
®
2100DC
®
OPERATION MANUAL
Dated: 03/15/2013
Document Name: StormPro_2100DC_OM
WARNING: Electrical shock hazard. This unit
has not been evaluated for use outdoors.
Never operate StormPro
Never operate StormPro
enclosure open.
Never operate StormPro
Never operate StormPro
liquid or moisture will come in contact with, splash on,
or drip on unit.
Do not insert or allow foreign objects to enter any
ventilation or exhaust opening as this may cause
electric shock, and/or a fire hazard.
WARNING: Risk of electrical shock. In the
event of a short circuit, grounding reduces
the risk of shock by providing an escape wire for the
electrical current. The StormPro
properly grounded.
The StormPro
®
having a grounding wire with an appropriate
grounding plug. The plug must be used with an outlet
that has been installed and grounded in accordance
with all local codes and ordinances. The outlet must
be the same configuration as the plug. Where a two-
prong wall outlet is encountered, it must be replaced;
contact a qualified electrician. To reduce the risk of
electric shock, the grounding plug must not be cut off
the plug. Do not use the three-prong plug with a two-
prong adapter. Do not attempt to defeat this safety
feature.
Use the StormPro
that is up to code. Connect to properly grounded
outlets only.
WARNING: Risk of electrical shock. The
®
StormPro
to generate electrical current when unplugged from the
wall outlet or when the AC power is shut off.
Because the StormPro
generate 120 volts of AC current, both the batteries
and the power cord must be disconnected to neutralize
the StormPro
2100DC . Failure to disconnect both the
®
batteries and the power cord could result in electrical
shock sufficient to cause injury or death.
Register your product at www.sumpro.com
Page 1 of 8
2100DC outdoors.
®
2100DC with battery
®
2100DC in a wet location.
®
2100DC in a location where
®
2100DC must be
®
2100DC is equipped with a cord
2100DC only with adequate wiring
®
2100DC is capable of and intended
®
2100DC uses batteries to
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2100DC and is the answer not in the manual?

Questions and answers

Summary of Contents for StormPro 2100DC

  • Page 1 Connect to properly grounded manufacturer may cause fire, electric shock, or injury outlets only. to persons. WARNING: Risk of electrical shock. The CAUTION: Do not sit or stand on StormPro ® StormPro 2100DC is capable of and intended ®...
  • Page 2 StormPro 2100DC OPERATION MANUAL ® Dated: 03/15/2013 Heavy Duty 12V DC Pump Document Name: StormPro_2100DC_OM Page 2 of 8 2. If electrolyte contacts the skin, wash it off attery recautIonS immediately. WARNING: Important safety instructions. 3. If electrolyte contacts the eyes, flush thoroughly Save these instructions.
  • Page 3: Pump Installation

    Tools Needed StormPro 2100DC OPERATION MANUAL ® A pipe wrench, pliers, adjustable wrench, pipe Dated: 03/15/2013 Heavy Duty 12V DC Pump cutter, and a screwdriver will be needed. Document Name: StormPro_2100DC_OM Page 3 of 8 Materials Needed PVC Pipe, appropriate PVC fitting, PVC glue and 3.
  • Page 4 StormPro 2100DC OPERATION MANUAL ® Dated: 03/15/2013 Heavy Duty 12V DC Pump Document Name: StormPro_2100DC_OM Page 4 of 8 1. Take the negative (-) black battery wire and fasten the ring terminal securely to the negative (-) battery post on top of the battery.
  • Page 5 StormPro 2100DC OPERATION MANUAL ® Dated: 03/15/2013 Heavy Duty 12V DC Pump Document Name: StormPro_2100DC_OM Page 5 of 8 Push the right side of the rocker switch to reset the rror Ight ndIcatIonS ‘Pump System Status’ LED after the pump has directly Note: This chart identifies light codes indicating to the legends on the charger housing (A.C.
  • Page 6 Please fill out and send back to: Metropolitan Ind. Warranty Department P.O. Box 7266 Romeoville, IL 60446. Or to register online, go to www.sumpro.com StormPro 2100DC Warranty Registration Card ® To register your purchase, please fill in the following information:...
  • Page 7 StormPro 2100DC OPERATION MANUAL ® Dated: 03/15/2013 Heavy Duty 12V DC Pump Document Name: StormPro_2100DC_OM Page 7 of 8 oteS Register your product at www.sumpro.com...
  • Page 8 Coverage and Term. Metropolitan Industries, Inc. (“Metropolitan”) warrants to the original purchaser (the “Buyer”) of each StormPro/Sumpro product (the “product”), that any part thereof which proves to be defective in material or workmanship within three (3) years from date of manufacture, will be replaced at no charge with a new or remanufactured part, F.O.B.

Table of Contents