The system adopts wireless digital coding, high-frequency emission and receiving, and the repetitive code rate is
very little, it adopts MCU control and on technology adopts SMT , it can connect all kinds of detectors our company
produce, for example PIR detector, door magnetism, smoke alarm, out-connected alarm, out-connected dial number
equipment, at the same time it gather wireless doorbell, tamper protection, low-voltage indicate. It has two remote
controllers, its operation is very convenient, it can guard your family from multi-orientation.

SPECIFICATION

1 voltage(power adapter convert):110VAC
2 standby power:9V/DC(6×AA)
3 operate frequency: 433MHz
4 operate channel:6(wireless channel has 6, 2 of 6 are also wire channels)
5 alarm method:sound and light alarm indicator
6 alarm current:150mA
7 out power static current: 26 mA
8 standby power static current:16 mA(when out power cut)
9 alarm time:3Min 30seconds
10 alarm sonority:90db
11 remote control distance: ≥30m( wide place)
12
battery low-voltage alarm:7.5V~7.9V
13 the system include unit: general controller(with power adapter)、single doorbell remote controller(battery
included) 、4-key remote controller(battery included) 、power adapter(input voltage 110VAC/230VAC, output voltage
10~12V/DC, current 1A) 、DPS-55 PIR detector(battery included)、door
magnetism(battery included). The unit for choosen: other type detector、
smoke alarm with RF、dial number equipment etc.
14 working LEDs:
Ch1~Ch4: red, wireless detector channel LED;
Ch5~Ch6: red, both wireless and wire detector channel LED;
Fortify: green, fortify LED;
Low-battery: green, battery low-voltage LED;
Power LED&Panic key: green, out power LED. when out power is
connected, it lights. At the same time, the key is panic key, press
the key, the general controller give panic alarm.

SUMMARY

1. channel indicate: when detector working, general controller
alarm and corresponding channel LED should light.
2. low-voltage indicate: when standby power is below set value, cut off out power, you can see Low-battery LED
flashing and remind you to replace battery in time.
3. tamper protection: when front cover is opened, general controller will give alarm, the 8 LEDs on the left and
right all flash.
4. two remote controllers:
single-key doorbell remote controller: power voltage DC12V, it can be installed out of the door and
used as remote control doorbell;
4-Key Remote Controller: power voltage DC12V, it is used for panic alarm, time-delay fortify, quick fortify,
cancel.
5. fortify: when host leave home, use remote controller to set general controller on fortify state, when someone
enter its detection field, general controller will give alarm (>90db), if connect dial number implement of our company,
General Controller will also give alarm weft, for example 110 or your home's telephone.
6. cancel: after host come back home and cancel the general controller's fortify state, when host enter detection
field, the general controller will not alarm.

HOME SECURITY CONTROL SYSTEM

DSW01
INSTRUCTION
230VAC
315 MHz
Ch1
Low-battery
Fortify
Ch2
Ch3
Ch6
Ch5
Ch4
Power LED&Panic key
GENERAL CONTROLLER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DSW01 and is the answer not in the manual?

Questions and answers

Summary of Contents for DSW DSW01

  • Page 1 HOME SECURITY CONTROL SYSTEM DSW01 INSTRUCTION The system adopts wireless digital coding, high-frequency emission and receiving, and the repetitive code rate is very little, it adopts MCU control and on technology adopts SMT , it can connect all kinds of detectors our company produce, for example PIR detector, door magnetism, smoke alarm, out-connected alarm, out-connected dial number equipment, at the same time it gather wireless doorbell, tamper protection, low-voltage indicate.
  • Page 2 7. panic alarm: when danger occur in your home, you can prees the panic key to give panic asking for help signal to neighbor or others and obtain other’s help. 8. alarm memory: on fortify state, when host isn’t at home there is person enter detection field, general controller alarm, after the alarm stops, the corresponding LED still light to indicate that channel ever had danger, only after using remote controller to reset, the LED will be off.
  • Page 3 the connection line between wire detector and general controller should not exceed 3m, and should install detector out of the way. OPEN FRONT COVER FIGURE BOTTOM COVER FIGURE(BACK) PRESS HIDDEN HOLE WITH POWER TO OPEN CROSSING-LINE CROSSING-LINE HIDDEN HOLE HIDDEN HOLE INSTALLING HOLE FRONT COVER INSTALLING HOLE...
  • Page 4 3. Attention: 3.1 Low-battery indicate: when the battery energy is below 7V, the low-battery LED in crystal board will flash once a second and you should replace the battery; 3.2 Avoid installing the unit on metal base; 3.3 Avoid installing the unit where sun shine or temperature change obviously, for example: air conditioning, heater etc.
  • Page 5 DSW-98A TK-9 Smoke detector Smoke detector PIR detector...

Table of Contents