Download Print this page

Intermatic ET171CR Supplementary Manual

Intermatic et171cr time switches: supplementary guide

Advertisement

Quick Links

Document1
8/26/03
TIMER SUPPLY:
120 V.A.C. 60 Hz. 3.0 Watts maximum
SWITCH RATING:
30 Amps Inductive/Resistive 24/120/240V A.C., 60 Hz.
20 Amps Resistive 28V D.C.
2 H.P.-240V A.C., 60 Hz.
20 Amps Ballast 277V A.C., 60 Hz.
ELECTRONIC 7-DAY TIME SWITCH (single pole single throw) with battery powered clock operation. For
direct control of loads up to 30 amps resistive or inductive and tungsten and ballast loads up to the switch
rating shown above.
RESET TIME SWITCH:
Press recessed RESET switch to reset microprocessor and remove all
previous set points.
TO SET TIME AND DAY OF WEEK:
Place three position selector in PROGRAM.
Place two position selector in CLK.
Press HOUR and MINUTE buttons to select current time and day (day
1 is Sunday, day 2 Monday, etc.,). Note clock is 12 hour AM/PM repeating.
TO PROGRAM SET POINTS:
Place three position selector in PROGRAM.
Place two position selector in OUTPUT.
Press HOUR and MINUTE buttons to select set point time.
Press DAY button to select day which ON or OFF set point is to occur.
Press ON/OFF button to select ON or OFF set points.
Press ENTER to enter selected set point time for the day selected.
To repeat the same set point for other day(s), use DAY button to select
the next day the set point is to occur, then press ENTER.
Repeat for as many days as required
Repeat above procedure for all remaining set points required.
TO REVIEW PROGRAM SET POINTS:
Place three position selector in PROGRAM.
Place two position selector in OUTPUT.
Display will show all zeros if there are no set points programmed.
If set points have been entered, the display will show a program time,
ON or OFF and the day the ON/OFF switching operation is to occur. The
display shows the first set point in chronological order beginning with
Sunday (day 1).
Press ENTER to review all remaining set points in chronological
sequence.
The display shows "E:nd" after last set point is displayed.
TO ADD OR DELETE SET POINTS:
To add set point time, press HOUR and /or MINUTE to change time
displayed. Then press ENTER. Set point is now added.
To delete a set point, press ON/OFF two times (display will show all
dashes).
*
FOR AUTOMATIC OPERATION, THREE POSITION SWITCH MUST
BE IN "AUTO".
For
battery
replacement,
battery 1.5 volts. To replace battery, press battery tray in and downward to
remove the battery holder. Replace battery, being sure to observe the correct
battery polarity. Replace battery __/__/__ (3 yrs. after installation of Time Switch).
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158ET10665
8:38 AM
Page 1
1 H.P.-120V A.C. 60 Hz.
5 Amps Tungsten 120/240V A.C., 60 Hz.
TIMER
POWER
PROGRAMMING
.
use
industrial
grade
MODEL: ET171CR
IN TYPE 3R RAINPROOF ENCLOSURE, SUITABLE
FOR POOL EQUIPMENT CONTROL IF INSTALLED
5 FT. OR MORE FROM EDGE OF POOL.
AA
standard
nonrechargeable
LR3730