Download Print this page

Calyenty RBH 125 Customer's Manual

Hide thumbs Also See for RBH 125:

Advertisement

Quick Links

Customer Manual
RBH125s. RBH185s - sms ready version 3.0s
October 2009
Warranty information.
Please note your warranty may be invalidated if you do not properly maintain the water
in your pool and all ancillary pool equipment, see the full warranty at the base of this
document. Also your warranty will be invalidated if the heat pump is not installed
following the procedures in THIS manual exactly.
Quick Reference.
Appearance of control panel screen and time clock under normal operating conditions:
Version 3.0s
Your heat pump will operate normally in Pool mode. This controller has various timer
functions that you will not need. You can set the date and time, apart from this, all you
need to set is your desired temperature with the arrow buttons. You can select Pool
mode by pressing mode until it appears. Above is how the screen should look under
normal working conditions.

Advertisement

loading

Summary of Contents for Calyenty RBH 125

  • Page 1 Customer Manual RBH125s. RBH185s - sms ready version 3.0s October 2009 Warranty information. Please note your warranty may be invalidated if you do not properly maintain the water in your pool and all ancillary pool equipment, see the full warranty at the base of this document.
  • Page 2 Remember during months where the outside ambient temperature drops to zero you must use the by-pass and drain down your heat pump. Always use a Calyenty heat pump cover when your heater is not in use.
  • Page 3 2. All electrical work should be carried out by a qualified electrician / lampista. 3. Check packaging for obvious signs of damage, before installation begins. Report any damage to Calyenty before installation if you have concerns. 4. Please read the Installation & Operation Manuals carefully before you install or operate the unit.
  • Page 4 8. Lift the heat pump into place onto the base. The lifting points are under the outside edge of the fan housing. Once the pump has been lowered onto base, make sure the screw holes line up and screw in the retaining screws, this fixes the main heat pump body securely to the base plate.
  • Page 5 12. Connect the supplied control panel to the snap connecters to complete the installation. The control panel can be mounted in a convenient dry place. 13. We recommend that the heat pump is fitted within 8 meters (25 feet) of the existing circulation pump for maximum performance.
  • Page 6 1.1 Features Titanium heat exchanger-- Most manufacturers adopt copper for heat exchanger production. The chemicals (chlorine, bromine and acid) in pool water are extremely corrosive to cooper heat exchangers. Calyenty adopts a titanium heat exchanger, which...
  • Page 7 Extra-wide heat exchanging area-- Except the electrical wiring and water connection area, the surface of Calyenty swimming pool heat pump is for heat exchange between the air and refrigerant in the evaporator. Extra-wide heat exchanging area gets more heat from the air and helps the unit heat the pool more quickly.
  • Page 8 • Please turn the unit off during the winter and drain out all the water by removing the drain plug. We recommend that you cover the machine with a Calyenty winter cover. • Use an accurate thermometer to measure the water temperature. A slight temperature difference may cause a considerable difference in energy consumption.
  • Page 9 2.1 Model Data: Oct-07 Calyenty Eco Heat Pump Specifications Item/Type Unit RBH 125 RBH 185 Pool Capacity Cu. Mtrs. Fan Location Heating BTU/H 42650 59368 Capacity 12500 17400 BTU/H 32414 54592 9500 16000 Power 1900 2750 Input 1800 2600 C O P 6.58...
  • Page 10 2.2 Illustrations:...
  • Page 11 3.Installation 3.1 Inspection of Unit Inspect the casing, unit and spare parts after receipt for possible damage in shipment. Check whether there are any breakages of the casing and cabinet, or deformation of the unit. The manufacturer shall not be responsible for any damage due to improper handling or shipping.
  • Page 12 Please note that the longer the pipes are, connecting your pool and the unit, the more loss of energy. We recommend the distance within 8 meters as the optimum distance between the unit and pool. Mount quick couplers with the unit inlet and outlet for convenient draining when servicing and winterizing.
  • Page 13 The water will flow down to the base plate through the fins into the collector tray. The Calyenty quick fit base collects the condensation and has a tap off point where...
  • Page 14 you can connect a hose to take the water to a convenient place , i.e. back to the pool or away from your terrace to avoid unsightly wet patches. 3.5 Electric Wiring General Requirements: Read the information in the manual before connecting. It is compulsory that a qualified electrical technician must check or install the wiring.
  • Page 16 Wiring Diagram Version 3.0s: Notice: above diagram is just for reference.
  • Page 17 The PCB:...
  • Page 18 3.6 Initial Startup Notice: the unit will not heat the pool when the water circulation pump is not working. The back lit controller screen will be blank. Starting Steps: Check whether the connectors, wires and cables of the unit, water pump, chlorinator, ozonizer, chemical pumps and control panel are correctly coupled or connected.
  • Page 19 5.1 Maintenance General maintenance: The unit should be maintained by qualified technicians on a regular basis. Ask Calyenty or your local dealer about our maintenance contract options. A professional technician should clean the unit periodically. It is NOT recommended to use a sprinkler to flush the unit.
  • Page 20 5.2 Troubleshooting The unit would not run. Is the screen of control panel lit? If not, ensure the electrical wires and cables are correctly connected and the power is on. If the screen displays E3 (version 3.0s), check the water flow. Whether the water pump is running normally or the filter is jammed? The unit will stop running automatically when the pool water reaches the set temperature.
  • Page 21 Instruction of SMS Control To use SMS control, the following are required: a) One available SIM card which accords to the local GSM network. b) Make sure this card can send and receive SMS without problem (remove any login code or pin while the SIM is in a standard mobile phone handset). c) Carefully insert the SIM card in the slot of the SMS control device as shown in picture.
  • Page 22 Spare Parts RBH125s Number /Name/ Model or Size V15 – 1 /PCB /V2.0 V15 – 2/ Control panel/ V2.0 V15 – 3/ Temperature sensor (black)/ 50K Temperature sensor (red) /50Kn+1% V15 – 4 /Fan motor capacitor/ 5uF/450V V15 – 5/ Compressor capacitor/ 50uF V15 –...
  • Page 23: Limited Warranty

    LIMITATION OF LIABILITY: This is the only warranty given by Calyenty. No one is authorized to make any other warranties on Calyenty products, . THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY.
  • Page 24 0034 972 660467. All returned parts must have a Returned Material Authorization number to be evaluated under the terms of this warranty. We strongly recommend that you take out a Calyenty maintenance contract.

This manual is also suitable for:

Rbh 185Rbh 174