WAGER RHW Series Manual

Wireless smoke opacity meter

Advertisement

Quick Links

W I R E L E S S S M O K E O P A C I T Y M E T E R
FULL FLOW HEAD
570 MONTROAL RD, RURAL HALL, NC 27045
(336) 969-6909 • 1-800-562-7024 (US) • WWW.WAGERUSA.COM

Advertisement

Table of Contents
loading

Summary of Contents for WAGER RHW Series

  • Page 1 W I R E L E S S S M O K E O P A C I T Y M E T E R FULL FLOW HEAD 570 MONTROAL RD, RURAL HALL, NC 27045 (336) 969-6909 • 1-800-562-7024 (US) • WWW.WAGERUSA.COM...
  • Page 2: Table Of Contents

    TABLE OF CONTENT WARRANTY……………………………………………………………………….…… 1 GENERAL…………………………………………………………………………...……2 SYSTEM PARTS LIST……………………………………………………………...……3 COMPONENT DESCRIPTION………………………………………………………..…4 INITIAL SET UP……………………………………………………………………….…8 SET UP FOR TESTING………………………………………………………………..…9 SNAP ACCELERATION TEST………………………………………………………...10 SNAP ACCELERATION TEST STEPS………………………………………………..11 FILTER VERIFICATION TEST……………………………………………………..…12 SAVE TEST SEARCHES……………………………………………………………….15 TECHNICAL SPECIFICATIONS………………………………………………………16 MAINTENANCE AND TROUBLE SHOOTING………………………………………17...
  • Page 3: Warranty

    WARRANTY Seller expressly warrants to Buyer (a) that the equipment will comply with the description set forth herein; (b) that the components and parts fabricated by Seller will be free from detrimental defects in workmanship and materials. If it appears within one year from date of shipment by Seller that the equipment does not meet these express warranties and Buyer gives Seller prompt and reasonable notice, Seller shall, at its option, either repair or replace at its expense, F.O.B.
  • Page 4: General

    GENERAL The Wager Model RHW Series 2 Full Flow Smoke Meter is in full compliance with the requirements of the SAE J1667 test criteria—the current U.S. standard. The system’s simple design, portability, and ease of use provide the user an effortless method to measure diesel exhaust opacity readings with an accuracy of + or –...
  • Page 5: System Parts List

    SYSTEM PARTS LIST Description Part Number HC Assembly 199-0000 SH Assembly Module 199-0012-BB Full Flow Yoke Assy 194-0002 Magnetic Band Clamp 194-0005 Transmitter Wireless Assy 199-0164 Receiver Wireless Assy 199-0165 Transmitter Cable Assy 199-0164-2 Receiver Cable Assy 199-0165-2 Charger, SH &HC 199-0005 SH Battery Pack 199-0003...
  • Page 6 Hand Controller The hand controller is a battery powered wireless device that contains the atmospheric sensors and is operated using the membrane keypad in the menu driven operation program. Charging jack in located on the left side of the HC. Sensor Head The sensor head assembly uses full flow technology and is attached to the vehicle...
  • Page 7 Power Packs There are two universal power packs that are used to charge the HC and SH and a third one to charge the printer. Portable Wireless Printer This wireless printer is battery powered with the power jack and on/off switch located on the back of the unit.
  • Page 8 Carrying case The case is used for transportation and storage of the system and provides individual compartments for each of the system components. Lifting the tray reveals the bottom section. Pole Brackets These brackets are used to mount the sensor head black box module to the telescopic pole.
  • Page 9: Initial Set Up

    INITIAL SET UP PRESS THE ON / OFF BUTTON TO POWER ON THE METER PRESS THE A KEY FOR CONFIGURATION PRESS THE E KEY FOR EDIT TEST FACILITY INFORMATION USE THE ARROW KEYS AT THE BOTTOM OF THE KEY PAD TO SCROLL THROUGH EACH LINE AND THE NUM ALPHA KEY TO ENTER NUMBERS.
  • Page 10: Set Up For Testing

    SET-UP FOR TESTING Installation of the Sensor Head No matter what style of exhaust system your vehicle has, the Full Flow style attaches the same way. Engage the magnetic hook over the lip of the pipe and fasten the band clamp using the latch and hair pin.
  • Page 11: Snap Acceleration Test

    SNAP ACCELERATION TEST The R.H.W. Series 2 Full Flow Smoke Meter has been designs in details to meet the specifications of the SAE J1667. The HC has a menu driven user interface that will prompt the user to enter required data, depress required buttons, and guide the user to completion of the snap test.
  • Page 12: Snap Acceleration Test Steps

    SNAP ACCELERATION TEST FROM THE MAIN MENU, PRESS THE M KEY TO ENTER THE SNAP ACCELERATION TEST. USING THE KEYPAD, ENTER THE VEHICLE INFORMATION. USE THE ARROW BUTTONS TO SCROLL EDIT DATA. START ENGINE. PRESS THE ENTER KEY TO BEGIN TEST. ENSURE THE SENSOR HEAD IS NOT IN THE STACK AND PRESS THE ENTER KEY.
  • Page 13 The system comes from the factory with a .2 neutral density verification filter. The filter has a known value of opacity. This opacity value is stored in the system and is used to verify the system is functioning properly. On a periodic schedule, run the filter test from the main menu. Follow the instructions displayed on the HC.
  • Page 14 Below is an example of a print out that will come from the wireless printer. 07:58:23PM MM/DD/YY Timeout is Enabled Revs. HC = X.XX SH = X.XX...
  • Page 15: Save Test Searches

    SAVE TEST SEARCHES FROM THE MAIN MENU, PRESS THE I KEY TO ENTER THE SAVE TEST SEARCHES OPTION ENTER A LETER CORRESPOINDING TO THE SEARCH YOU ARE TRYING TO PERFROM. FOLLOW THE INSTRUCTIONS IN GREEN. ONCE COMPLETE, PRESS THE ENTER KEY. USE THE ARROW KEYS TO SCROLL THROUGH TO THE DESIRED TEST.
  • Page 16: Technical Specifications

    TECHNICAL SPECIFICATIONS The R.H.W. Series 2 Full Flow Smoke Opacity Meter meets the SAE J1667 specification for diesel emission testing. Accuracy The system is designed to be accurate within + or – 1.0% opacity. The control unit self calibrates each time it is powered on under clear stack conditions with self tests at 0% and 100%.
  • Page 17 MAINTENCE & TROUBLESHOOTING The RHW Series 2 Full Flow is built around the most current technology and high grade components. All parts have a 1 year factory warranty so if the unit is new, do not attempt to alter or replace any of the parts without consent of the factory as this may void the warranty.
  • Page 18 OPTIC CABLES These head duty cables are used to connect the transmitter / receiver to the wireless sensor head black box module. The cables are keyed so they cannot be connected incorrectly Sensor Head Black Box Module The sensor head module is a sealed unit and no maintenance is required for the operation of the meter. Ensure the battery is fully charged as indicated by the Led on the charging unit.
  • Page 19 Each state or country uses different values for different vehicle years to determine if the vehicle is emitting soot in excess of the limits set by the local guidelines. The RHW Series 2 Full Flow does not determine if the vehicle passes or fails a emission test. It is up to the user to know the local regulations and use the average opacity printed out on a valid test report to compare this result with values stated in the local regulations.
  • Page 20 Wireless Channels The system communicates via wireless signals that operate on distinct channels labeled C – N. All devices that are considered a system all must be assigned to the same channel. So if the HC is on channel H, the SH and printer must also be assigned to channel H. The user can run an energy scan to inspect the local environment to see which channel provides the best communication.

This manual is also suitable for:

8500