Sonelastic SA-BC Installation And Operation Manual

Adjustable support for bars and cylinders

Advertisement

Quick Links

Installation and Operation Manual
SA-BC
Adjustable support for bars and cylinders
ATCP Physical Engineering, Sonelastic
Division
Lêda Vassimon, 735-A - Ribeirão Preto - Brazil - 14026-567
Telephone: +55 (16) 3289-9481
www.sonelastic.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SA-BC and is the answer not in the manual?

Questions and answers

Summary of Contents for Sonelastic SA-BC

  • Page 1 Installation and Operation Manual SA-BC Adjustable support for bars and cylinders ATCP Physical Engineering, Sonelastic  Division Lêda Vassimon, 735-A - Ribeirão Preto - Brazil - 14026-567 Telephone: +55 (16) 3289-9481 www.sonelastic.com...
  • Page 2 Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Installation and Operation Manual SA-BC Adjustable support for bars and cylinders Manufactured by: ATCP do Brasil – Alves Teodoro Cerâmicas Piezoelétricas do Brasil Ltda. ATCP Physical Engineering, Sonelastic  Division Rua Lêda Vassimon, 735-A...
  • Page 3 Copyright Copyright © 2010-2022 by ATCP Physical Engineering All rights reserved. ATCP reserves the right to change the product or this manual without notice. Version 5.0 January/2022...
  • Page 4: Table Of Contents

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders TABLE OF CONTENTS 1. Introduction ....................05 2. Definitions ....................05 3. Features and applications ................05 4. Configurations, parts, accessories and optional items ........06 5. Parts identification ..................08 6.
  • Page 5: Introduction

    ® Systems. SA-BC Support allows rectangular and cylindrical specimens to rest on the nodal lines of the fundamental flexural vibration mode (for a specimen of length L, these nodal lines are 0.224L distant from the ends). Based on the size and weight of the specimen to be tested, this support offers a practical system to adjust the distance between the support-cables, as well as the traction on them.
  • Page 6: Configurations, Parts, Accessories And Optional Items

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 4. Configurations, parts, accessories and optional items SA-BC Support is available in both manual and automatic configurations. Optional items are offered to customize the Sonelastic ® Systems. Manual configuration Parts: Optional Items: [01] –...
  • Page 7 Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Automatic configuration Parts: [01] – SA-BC Support; [02] – CA-PD Acoustic Sensor. Accessories: [03] - Sturdy Tripod; [04] - Spare Support-cable set; [05] - Height-adjusting disc; [06] - IED Automatic Impulse Device / Control unit;...
  • Page 8: Parts Identification

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 5. Parts identification SA-BC Support 01- Support base; 02- Support-cable tightener; 03- Spare Support-cable set*; 04- Leveling feet; 05- Mobile support base; 06- Anchoring terminal; 07- Supporting sleeve; 08- Fixed posterior support-tube;...
  • Page 9: Specifications

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Sturdy Tripod 01- Frame; 02- Articulated tripod; 03- Handle for securing the tube; 04- Pillar; 05- Handle for the tube articulation; 06- Acoustic sensor clip; 07- Inner tube; 08- Handle for the inner tube articulation;...
  • Page 10: Specimens

    Note: Minimum dimensions may vary as a function of aspect ratio and material Young’s modulus; the frequency should be lower than CA-DP Acoustic Sensor maximum frequency (96 kHz). It is possible to estimate the frequency using Sonelastic  Software simulation tool.
  • Page 11: Placing The Specimen

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 7.2 Placing the specimen The specimen should be symmetrically placed over the support-cables, with those at a distance of 0.224 L from the specimen ends (L is the specimen length). For instance, if a specimen’s length (L) is 100 mm, the support-cables should be positioned at a distance of...
  • Page 12: Support Installation

    - A flat and leveled workbench with a free space of at least 60 x 120 cm (depth and width). This space is enough to fit SA-BC Support, specimens, computer and optional items. - A 127 or 220 VAC three-pin ground wired electrical mains plug. This plug is needed to power the computer up.
  • Page 13 Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Configuration: Manual. Specimen: Medium size rectangular section bar. Acoustic sensor: Using a Sturdy Tripod (an optional item to be used in manual configurations) for optimum signal acquisition of the longitudinal mode.
  • Page 14 Attention! Before using SA-BC Support, verify if its four rubber feet are on the workbench (not wobbly). If any of its feet is not flat on the workbench, readjust it until all feet are securely placed and flat on the surface.
  • Page 15: Mounting The Acoustic Sensor In The Vertical Base And Sturdy Tripod

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 8.3 Mounting the acoustic sensor in the vertical base and Sturdy Tripod In the vertical mounting base: Step 01 - Insert the acoustic sensor in the vertical mounting base ensuring the wire goes...
  • Page 16: Replacing The Support-Cables

    SA-BC Support is supplied with a Ø1.20mm support-cable set (this is the recommended cables to be used with specimens weighting between 10 and 30kg). To replace them for the Ø0.70mm support-cables (recommended for specimens weighting up to 10kg), follow the...
  • Page 17: Installing The Ied Automatic Impulse Device

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders For light specimens (weighting up to 10kg), tension the support-cables until fully straight. The sliding support tube allows the fine adjustment of tension on the support-cables. For heavy specimens, adjust the tension on the cables so that, when the specimen is placed over...
  • Page 18: Support Operation

    SA-BC Adjustable support for bars and cylinders 9. Support operation After following 8 – Support Installation steps, the SA-BC Support will ready for use. 9.1 Positioning the specimen To carry out a fast and precise characterization of specimens using SA-BC Support: Step 01: Install the support according to the specimen weight (see 8 –...
  • Page 19: Positioning The Acoustic Sensor

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 9.2 Positioning the acoustic sensor Step 01: Mount the acoustic sensor in the Sturdy Tripod clip or in the vertical mounting base, as described in 8.3 – Mounting the acoustic sensor in the vertical base and on the Sturdy Tripod;...
  • Page 20: Positioning The Ied Automatic Impulse Device

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Step 03: Configure the intensity of the shock from the Impulse Device against the specimen (see more information in the Instructions Manual that comes together with IED Sonelastic). Note: All information regarding the IED Automatic Electromagnetic Impulse Device has been described in detail in its Installation and Operation Manual.
  • Page 21: Acquisition And Excitation Modes

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 10. Acquisition and excitation modes The table below describes the most practical positions of the acoustic sensor and impulse device for characterizing rectangular specimens, using flexural, torsional and longitudinal vibration modes.
  • Page 22 Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders The next table provides additional information focused on cylindrical specimens. Flexural mode - I Excitation from above and signal acquisition from below, both aligned with the center of the specimen.
  • Page 23: Warnings And Support Transportation

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders 11. Warnings and support transportation Reading all the information contained in this Installation and Operation Manual is compulsory for the correct use of the support; The power outlet where the computer will be connected must have a functional ground pin;...
  • Page 24: Symbology

    After the 12 months of warranty, parts, expenses and services shall be charged. 15. Statement of responsibility ATCP Physical Engineering takes total technical and legal responsibility over the SA-BC Support and guarantees that all information here provided are true. Pág. 24 de 25...
  • Page 25: Notes

    Sonelastic ® Systems SA-BC Adjustable support for bars and cylinders Notes: ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................Pág. 25 de 25...

Table of Contents