Section 2a – INSTALLATION
Control Box
CONTROL BOX converts incoming
AC power to a Low Voltage DC current,
which energizes the Cell(s). Set the
Control Box on a vertical surface away
from excessive exposure to heat and
moisture. Use the template to mark and
drill the (4) mounting holes and insert
the screws, leaving a ¼ in. gap. Hang the
control box on the screws and level.
Remove the cover by following the steps
on page 12 to access the mounting
holes to tighten the screws.
RATINGS:
Input Power: 115 VAC (3.0 AC amps)
230 VAC (1.5 AC amps)
50/60 Hz
Output Power: Cell Power 1 (5.0* DC amps) Agency Approvals: NSF, ETL us, ETL c, CE
Cell Power 2 (6.5* DC amps)
Cell Power 3 (8.0* DC amps) Internal Pump Relay is rated for 30-amp max.
*Indicates nominal amperage output. The dual axis controller will slightly vary the amps to optimize the power to the cell.
The cell and tri-sensor are located in a Flow Bypass Manifold Assembly. 3.6 m (12 ft.) of Cell and Tri-Sensor cords are
provided with the unit. Ensure that the manifold is located within that distance from the control box with enough slack to
allow for removal for service or maintenance.
The Digital display provides full information and diagnostic for maintenance and operation of your system. The programmable
settings are retained on a microprocessor chip with the clock setting backed-up with a CR-2025 lithium battery.
CAUTION: It is suggested to locate the cell downstream of all other equipment and on the pool return line only to avoid
over-saturation conditions of your spa. For applications other than as recommended, contact the factory.

Main Components

Tri-Sensor Assembly
union
Flow In
Flow Bypass Manifold Assembly
ELECTROLYTIC CELL
receives Low Voltage DC current from
the Power Circuit Board, which initiates
the electrolytic process. This process
converts ordinary table salt (Sodium
Chloride) to 100% Pure Sodium
Hypochlorite (Chlorine Bleach) or
Bromine (with the addition of Sodium
Bromide), which in turn sanitizes your
pool or spa.
See page 10 for salt requirements.
Maximum Output:Equivalent to 0.58 kg (1.28 lbs) of free available chlorine/day
RC-5 Cell@ Power Level 3 (8 amps DC)
Cell Life Expectancy: A minimum of 15,000 ampere/hours
4
DIG 36 = RC5 Cell
Flow Out to pool
TRI-SENSOR ASSEMBLY
ensures that adequate flow,
94.5 L/min. (25 US Gallons/min.)
minimum; salt, 2.8 – 3.2 gm/l
(2800–3200 ppm) ideal range; and
water temperatures, above
15.6 °C (60°F) are satisfactory to
prevent abusive conditions for the
cell to operate. See page 12 for
instructions to remove and inspect
the tri-sensor assembly.