NDTUM-GTAG-EN REV2.0 1. Product Overview Thank you for purchasing G-Tag, the smart gas detector of NodeTalks Corp. G-Tag is an ultra-compact/ultra-light portable gas detector that can measure the concentration of oxygen(O ) and toxic gas(CO, H S, etc.). This product is an IoT device that focuses on securing safety and user convenience in the industrial fields.
2. Product Specification * Type of gas that can be measured with the actual product may differ depending on the G-Tag product model. Please check the product model and type of measuring gas before use(See page 6) Carbon Hydrogen sulfide Type of Gas Oxygen (O monoxide(CO)
Contact NodeTalks Corp.. if the sensor or the battery require replacement. Do not power off the products(for a long time) since this product carries out automatic calibration of the gas sensor. It is recommended to keep the gas detector in a safe place with the power on when not in use.
Specific Conditions of use: ※ i. The equipment is a hand-held & portable device. Where a static-generating mechanism is identified, such as repeated brushing against clothing, then suitable precautions shall be taken, e.g. the use of anti-static footwear. ii. As aluminum is used at this equipment, ignition sources due to impact and friction sparks could occur, this shall be taken into account when the requirement is used in zone 0 location.
* Vibration motor pattern: operate 2 times per second at the interval of 5 seconds (common) ** Please contact to manufacturer (NodeTalks Corp.) if the criteria of other toxic gas (not specified above table, such as NO, SO ) is required.
Page 8
Recommended Usage: ”Be sure to“ check the LED pattern before using the product to see whether the G-Tag operates in detection mode(Green LED blinks). If there is no separate operation, G-Tag operates in the detection mode and measures the concentration of gas in real time.
6. Product Name Plate Product Nameplate Nameplate of this product is attached on the rear side (refer to figure on page 3) of the product as shown below, and it contains the following informations: product model, certification mark and number, manufacturer, serial number, etc.
B. Certification Details G-Tag, our smart gas detector, has obtained domestic/foreign explosion-proof certification for intrinsic safety and complies with the following standards. IEC 60079-0:2017 IEC 60079-11:2011 EN IEC 60079-0:2018 EN 60079-11:2012 CAN/CSA C22.2 No. 60079-0:2019 CAN/CSA C22.2 No. 60079-11:2014 CSA C22.2 No. 61010-1-12:2012 ANSI/UL 60079-0 (7 Edition) ANSI/UL 60079-11 (6...
Page 14
C.2 Allow Permission and Accept Terms and Conditions The following figures show the permission screens that appear when you first run the app after installing it. Press the “OK” button and then “Allow” the file access permission and location access permission. The figure on the top of the next page (p.
Page 16
If the app is running, the text indicating the app running status is displayed in the notification area at the top of the smartphone (figure on the bottom left). To show the information rapidly in case of alarm, the app will not be terminated even if you click the Back button.
Page 18
If a recipient is added in the emergency contact network, it automatically notifies of the dangerous situation of the app user by text message. concentration of gas currently exposed, name, phone number and location information of app user is sent to the contact of the recipient saved earlier.
Page 20
C.5 Other Functions C.5.1 Register Network of Emergency Contact You can register or delete the targets to send a danger text when receiving warning alarm in the emergency contact network of the dedicated app. Click the contact in the address book and then click the Register button that appears on the lower right, the relevant recipient will be registered in the emergency contact network (left figure).
Page 22
Span calibration should be performed at least every 6 months for accurate detection results. Separate test gas is required for span calibration. Contact NodeTalks Corp.. if any problem occurs during calibration. ※ User Precautions for Calibration i. It is recommended to calibrate the gas concentration in a room temperature. Since toxic...
Page 24
When you turn on the power of G-Tag again, the name of device available for connection is displayed as shown in the following figure on page 21(if it is not displayed in the list of device available for connection right after turning on the power of G-Tag again, press the Scan button on the right upper part).
Page 26
D.4 Span Calibration Span calibration process is to calibrate so that the same concentration as test gas comes out from the gas detector after injecting the test gas of specific concentration. After selecting the “Span Calibration” menu in the calibration page of the dedicated app, enter the type of gas sensor to calibrate and the value of test gas.
Carbon monoxide(CO) sensor related errors Hydrogen sulfide(H S) sensor related errors - If self-diagnosis error occurs, turn off the device and turn int on again. - If the problem persists, contact NodeTalks Corp. E-mail: office@nodetalks.co.kr Website: www.nodetalks.co.kr Smart Gas Detector / G-Tag ***...