keyes
-------------- HM-10 module configuration, requires USB to TTL device. Not wireless pairing is
configured! (Because of wireless pairing, the data is directly transmitted)----------
1. If the LED is not paired with the remote device, the LED flashes slowly. At this time, the AT command
can be used to configure the module.
2. HM-10 module can only recognize all uppercase AT commands, and does not support lowercase and
uppercase mixed writing.
3. Factory default baud rate is 9600 8n1
Slave setting
AT+BAUD0 //9600 will be powered off and restarted after the setting is completed.
AT+NAMEAC
AT+PASS000000 //You must enter 6 digits
AT+TYPE1
AT+ROLE0
https://keyes-robot.taobao.com