Advertisement

Quick Links

GB
AS/NZS
USER AND MAINTENANCE MANUAL
Read carefully and keep for future use
GIANO 70 / GIANO 70 VD
R290
ORIGINAL INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for GALILEI GIANO 70

  • Page 1 AS/NZS USER AND MAINTENANCE MANUAL Read carefully and keep for future use GIANO 70 / GIANO 70 VD R290 ORIGINAL INSTRUCTIONS...
  • Page 2 THANK YOU ! Dear customer, We thank you very much for choosing a product of Galilei Refrigerazione. We wish you a profitable and successful use of this cabinet, meanwhile we kindly ask you to read carefully the content of this manual before its installation and use. The instructions of this manual will provide you all the necessary information to guarantee a safe, effective, and long-lasting use of this equipment.
  • Page 3 FOR YOUR SAFETY Cabinets working with flammable refrigerant R290 (Propane) End-users and service personnel are required to fully understand and observe the following instructions. Notice: cabinets working with flammable refrigerant are identified by a specific label applied to the side of the base. The Type of refrigerant is also specified in the rating plate, see below picture. Each and every operator, as well as the maintenance personnel, must carefully read und fully understand or have these instructions explained before using this equipment.
  • Page 4 Warning!! In case the cable or the plug is damaged, ask for a prompt replacement by qualified maintenance personnel. SERVICING, MAINTENANCE AND REFRIGERANT HANDLING R290 is classified as flammable refrigerant of Class A3 according to ANSI/ASHRAE. It is a highly flammable and very easy to ignite.
  • Page 5: Table Of Contents

    INDEX General data and features ………………………………………………………………………… General dimensions Unloading and handling of the cabinet Noise level, weights Position of water draining outlet and power connection General recommendations …………………………………………………………………………………….. 5 Placement of the cabinet Electric connections Preserving the displayed products Cleaning Maintenance Safe use of the cabinet Nameplate ……………………………………………………………………………………………………….…...
  • Page 6: General Data And Features

    GENERAL DATA AND FEATURES GIANO 70 promotional refrigerated cabinet Self-service refrigerated cabinet with forced air circulation and built-in condensing unit, suitable for the displaying and merchandising of pre-packed food such as salami and cold meats, cheese, milk and dairy products, delicatessen, fruits and vegetables. Complete with endwalls, display decks in galvanized steel powder-coated, front bumper-rail in stainless steel D.
  • Page 7: Unloading And Handling Of The Cabinet

    Cross Section Basement front-panel Defrost water tank Front levelling feet Control panel Rear swivelling wheels with brakes Air intake baffle Sliding guides Display decks Side bumper-rail Fan panel Endwall Load limit mark Front bumper-rail Evaporator Condenser cladding panel Insulated carcass Condensing unit Air discharge baffle Cable-wrap bracket...
  • Page 8: Noise Level, Weights

    55 dBa (according the conditions defined in the norm EU 89/392/CEE). Maximum Loading Maximum Loading for Giano 70 is 90kg/m2 uniformly applied. Considering the available display surface of both models, the overall limits are: Giano 70 L:937...
  • Page 9 Water draining outlet (PVC pipe D.40mm) Evaporator piping opening Bottom cable-exit (1) (2) Alternative exits (blind) Cod. 80000070b – 23.04.2013...
  • Page 10: General Recommendations

    GENERAL RECOMMENDATIONS It is hardly necessary to pay attention to the following instructions and guidelines, as well as to the pictograms and their meanings. The topics included in this section of the manual have been categorized and grouped according the following criteria: NOTICE: information for a correct and effective use of the equipment.
  • Page 11: Electric Connections

    Before operating the cabinet, feet/supports must be adjusted so that the unit is stable and perfectly horizontal. Such condition is necessary to guarantee a proper drainage of the defrost water and a running of the equipment without vibrations and noises. In case, adjust the levelling feet (if present) checking at the same time the horizontal alignment with a spirit level, both along the length and the width of the cabinet.
  • Page 12: Preserving The Displayed Products

    Cabinets with remote condensing unit: electric connections and start-up must be carried out exclusively by qualified technical personnel. Cord plugs of external devices/equipment produced by third parties (e.g. slicing machines, weighing machines etc.), and/or power lines for additional sockets (possibly delivered as accessories), will have to be connected to separated power lines installed by qualified personnel, properly sized and protected in respect of the loads to be connected.
  • Page 13: Cleaning

    The cabinets are equipped with an automatic system for the cyclic defrost of the evaporator. This system is handled by the electronic controller of the control panel. Defrost parameters are pre-set in factory according the necessities and specificities of each unit. In particular cases it may be necessary to manually initiate a defrost cycle, by operating the related function of the electronic controller (make reference to the section of the manual dedicated to the electronic controller).
  • Page 14: Maintenance

    Cleaning of the external parts: a frequent cleaning routine helps to keep the cabinets presentable, to preserve it for a long-term use and to convey a sense of cleanliness and hygiene to the customers. It is therefore recommended to clean frequently the external parts of the cabinets, such as glass superstructure, backshelves, cladding panels, aluminium profiles, etc.
  • Page 15: Safe Use Of The Cabinet

    Safe use of the cabinet This appliance cannot be used by people, including young children, whose physical, sensorial or mental capacities are reduced, or by people who are not properly trained unless they are supervised by a person responsible for their safety. Young children should be supervised to ensure that they do not play with the appliance Unsuitable use of the unit, or part of it, is strictly forbidden.
  • Page 16 Cod. 80000080c – 17.07.2018...
  • Page 17: Nameplate

    NAMEPLATE The nameplate is normally placed beside the control panel, or inside the counter in case of multideck or island unit. The plate contains all the necessary information to identify the unit, and the technical specifications for its correct installation and functioning. The cabinet is subject to WEEE Europena Directive 2002/96/EC (only for plug-in cabinets) RoHS The cabinet is compliant with RoHS European Directive 2002/95/EC (only for plug-in cabinets)
  • Page 18 Meaning of the rating plate fields Model name, with length in centimeters and possible additional marks identifying a given version Attention: this information must always be provided when requiring any spare-part Serial number, code and/or configuration number (if present) Attention: this information must always be provided when requiring any spare-part Year of manufacture Climatic class, indicating the proper environment conditions in which the unit operates correctly.
  • Page 19: Setting-Up And Starting The Unit

    TECHNICAL SECTION W A R N I N G This section of the manual is intended only for installation technicians and maintenance personnel. Cod. 80000110a – 22.01.2014...
  • Page 20: Installation Of Front Glasses And Endwalls

    INSTALLATION AND START-UP Installation of the front glasses Front glasses are kept in their mounting position by longitudinal slots made on the top side of the front facias. Once removed the packaging of the glasses and the protective films, insert the lower rim of each glass inside the slots, gently pressing downwards until they reach the bottom of their respective slots.
  • Page 21: Installation Of The Air-Baffles

    Installation of the air baffles Caution: the installation of both air baffles is obligatory, as functional part of the aeraulic circuit. Their possible non-installation compromises a proper functioning of the unit and its capability to preserve the displayed product. The lower side of both air baffles has to be inserted in the slots between display decks and air intake/discharge grills, as shown in the drawing below.
  • Page 22 Air-intake baffle and air-discharge baffle have different shapes and functions. It is hardly recommended to observe the right mounting position. The air-intake baffle is constituted of only 2 walls of acrylic glass; it must be installed on the front side of the cabinet, where the digital thermometer is also installed.
  • Page 23: Assembling And Installation Of The Bumper Rails

    BATTICARRELLO–STOßLEISTE–PARE CHOC–BUMPER RAIL Mod.: GIANO 20’ 4 pcs. M6x20 16 pcs. Cod. 80001850 – 10.11.2014...
  • Page 24 Cod. 80001850 – 10.11.2014...
  • Page 25 Cod. 80001850 – 10.11.2014...
  • Page 26: Multiplexing

    CANALIZZAZIONE–ZUSAMMENBAU CANALISATION-MULTIPLEXING Mod.: GEMINI / GIANO 35’ M6 (X8) ! Only for Gemini ! …4 ÷ 5 Cod. 80002380a – 04.08.2015...
  • Page 27 ! Only for Gemini ! ! Only for Gemini ! #1 & #2 M6 (X20) Cod. 80002380a – 04.08.2015...
  • Page 28 …10 ÷ 18 Cod. 80002380a – 04.08.2015...
  • Page 29 …24 ÷ 27 Cod. 80002380a – 04.08.2015...
  • Page 30 Pagina lasciata bianca intenzionalmente This page intentionally left blank Diese Seite wurde absichtlich leer gelassen Page laissée volontairement blanche Pàgina dejada blanca expresamente Cod. 80000160a – 22.01.2014...
  • Page 31: Control Panel, Parameters Table And Wiring Diagrams

    GIANO, ARIES, GEMINI R290 DIXELL XR50CX INDEX Control panel (DIXELL XR50CX) ……………………………………………………………………… Electronic controller, switch-on and switch-off of the unit Normal conditions of operation User-level settings User interface, Set-point temperature Defrostings, Alarm warnings LED Lighting system ……………………………………………………………………… SECTION RESERVED TO INSTALLATION AND MAINTENANCE PERSONNEL Programming of the controller ……………………………….………………………………………...
  • Page 32 CONTROL PANEL (DIXELL XR50CX) This cabinet with built-in condensing unit has a control panel equipped with an electronic controller (pos.2) DIXELL mod. XR50CX. This microprocessor-based controller is equipped with a LED display and has been specifically developed for the management of refrigerating units, display cabinets and showcases. The LED display contains 3 digits and a decimal point, for an easy reading of temperatures, parameters and their respective values.
  • Page 33 product label). For the modification of the set point make reference to the following chapter of this manual. Attention: The cabinet is equipped with a digital thermometer placed inside the display area, (commonly inside the air-intake grill, just behind the front glass). The preserving temperature is exclusively displayed by this thermometer, and not by the display of the electronic controller.
  • Page 34 User Interface – keypad The keypad consist of 6 buttons, whose multiple functions are described below. ATTENTION: The “On/Off” button is not an isolator switch and, as factory default, it is disabled by a specific parameter (“onF” parameter). It is recommended not to change this factory setting. In case this function must be enabled, ask the service personnel to modify the parameter mentioned above.
  • Page 35 Min. Temperature recorded Press and release the DOWN button. The “Lo” message will be displayed followed by the minimum temperature recorded. By pressing the DOWN button again or by waiting 5sec. the normal display will be restored. Max. Temperature recorded Press and release the UP key.
  • Page 36 Alarm Recovery Probe alarms P1”, “P2”, “P3” and “P4” start some seconds after the fault in the related probe; they automatically stop some seconds after the probe restarts normal operation. Let the connections to be checked by maintenance personnel before replacing the probe. Temperature alarms “HA”, “LA”...
  • Page 37 Pagina lasciata bianca intenzionalmente This page intentionally left blank Diese Seite wurde absichtlich leer gelassen Page laissée volontairement blanche Pàgina dejada blanca expresamente Cod. 80000160a – 22.01.2014...
  • Page 38 LED LIGHTING SYSTEM On/Off switching via Dixell XR50CX If installed, the optional LED lighting system is operated via the keyboard of the electronic controller, by pressing the button shown in the below pictures. Please note that the icon on the button can vary according to the different versions of the same controller.
  • Page 39 TECHNICAL SECTION W A R N I N G This section of the manual is intended only for installation technicians and maintenance personnel. Cod. 80000110a – 22.01.2014...
  • Page 40 PROGRAMMING OF THE CONTROLLER (DIXELL XR50CX) Attention: the access to the programming menus and the modification of the parameters are exclusively reserved to installation and maintenance personnel. A wrong or improper modification of the parameters can lead to malfunctions and/or to a lack of performances. Parameters categories and access to the menus Working parameters are grouped in two different categories: “Pr1”...
  • Page 41 Special Functions Enable / disable the keypad Used to prevent the set point and the other working parameters from being changed when the equipment is located in a place accessible to the public. In order to activate the keyboard lock, keep pressed simultaneously the UP + DOWN buttons for a few seconds, until the blinking message “PoF”...
  • Page 42 PARAMETERS TABLE Attention: the access to the programming menus and the modification of the parameters are exclusively reserved to installation and maintenance personnel. A wrong or improper modification of the parameters can lead to malfunctions and/or to a lack of performances. Cabinet type: Giano R290 Gemini R290...
  • Page 43 Delay of temperature alarm at startup 0÷23h50’ np÷P4 Sensor for temperature alarm of condenser (np,P1,P2,P3,P4) °C -55÷150 Condenser low temperature alarm °C -55÷150 Condenser high temperature alarm °C 0.1÷25.5 Differential for condenser temp. alarm recovery 0÷254 Condenser temperature alarm delay 0÷23h50’...
  • Page 44 9C@< > == = < C@ A "; " " % & % " " " " #) " " " " ,- " - " " ( " 0/ ! " " + "- , " ,- " " - "...
  • Page 48 GALILEI REFRIGERAZIONE S.P.A. – VIA VENETO 29/31 – 35020 DUE CARRARE (PD) – ITALY Tel. +39 049 99 30 650 Fax +39 049 52 11 341 WWW.GALILEISPA.IT...

This manual is also suitable for:

Giano 70 vd

Table of Contents