Download Print this page

BOSHART 850-WSP Operation, Maintenance And Installation Manual page 2

Water sensor probe

Advertisement

850-WSP
OPERATION, MAINTENANCE
AND INSTALLATION MANUAL
DESCRIPTION OF OPERATION & MAINTENANCE CONTINUED
1.
Disconnect Power. Determine location for water detection. See Figure 1
2.
Install the ALARM PANEL per Installation Instruction for the ALARM PANEL.
3.
Secure the sensor to the discharge pipe at the desired alarm level (the alarm level will be when the liquid touches the metal at
the bottom of the probes). See Figure 5. Note: Use a tie strap to further secure the cable to the discharge.
4.
Connect the Water Sensor Probe to the ALARM. CAUTION! – Red wire must be connected to the "C" terminal and the Black wire
must be connected to terminal 2. See Figure 2. Note: If a float switch is added use "C" and "1"
5.
Test product weekly. For the ALARM PANEL, make sure the green "Normal" light is "on". Press the "Test" switch, the red alarm
light and buzzer should turn "on". If the battery backup system is utilized, unplug the wall mount power supply (the green light
will be off). Now press the "test" switch, the red alarm light and buzzer will turn "on". If the buzzer sounds less loud than when
tested with the normal power supply, then replace the battery. Refer to instructions on installing/replacing the battery on
page 2 of the ALARM PANEL installation Instruction. Reconnect power supply when finished to put the ALARM PANEL back into
service. Test the Water Sensor Probe by immersing the probes in water or place a wet rag or sponge across the probes. The
ALARM PANEL should activate. Completely wipe and dry probes before putting unit back into service. See Figure 3.
FIGURE 1
FIGURE 4
SUMP BASIN
Multiple Water Sensor Probes can be connected
for zone protection.
Water Sensor Probe
FIGURE 2
BOSHART.COM
FIGURE 5
FIGURE 3
The ALARM PANEL is able to monitor different
areas using multiple sensors such as float
switch and Water Sensor Probe simultaneously

Advertisement