NewTom 5G Installation Manual

NewTom 5G Installation Manual

Cone beam 3d imaging
Hide thumbs Also See for 5G:

Advertisement

Quick Links

0051
97070025
Rev. 2
28.10.2016
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NewTom 5G

  • Page 1 0051 97070025 Rev. 2 28.10.2016...
  • Page 2 CEFLA s.c. The original version of this manual is in english. NEWTOM™ 5G is a trademark of CEFLA s.c. All other products and trade names mentioned in this document are registered marks of the relevant manufacturers.
  • Page 3: Table Of Contents

    Table of Contents 1 UNPACKING AND MOVING THE EQUIPMENT............1-1 1.1 Scanner Inspection And Unpacking Instructions.............1-1 1.2 Moving The Equipment..................1-10 1.3 Patient Table Inspection And Unpacking Instructions.............1-12 2 MOUNTING AND CONNECTING THE EQUIPMENT.............2-1 2.1 Lasers Setup...................... 2-1 2.2 Mounting The Equipment..................2-1 2.3 Connecting The Equipment..................2-7 2.3.1 Connecting The Electric Distribution..............2-7 2.3.2 Connecting The Console Workstation..............2-7...
  • Page 4: Unpacking And Moving The Equipment

    Electro Static Discharges (ESD) may occur. Please refer to the “Service Manual” document for a proper protection against ESD. 1. Carefully open the crate with the help of a hammer and crowbar. Remove the top and all four-side panels. NewTom 5G – Installation Manual...
  • Page 5 Do not attempt set-up, installation, or operation of any damaged system. 3. From the base of the crate remove the two lifting tubular bars, the two flat junctions bar and the four “T” shaped lifting screws. 4. Remove the bubble wrap protection from the scanner. NewTom 5G – Installation Manual...
  • Page 6 Unscrew the M4x20 self-tapping screw located on the bottom side of the Plastic Ring. Unhook the Plastic Ring from the 2 top inserts, then disconnect the control panels (C8 and C9 connectors) and the emergency buttons on both left and right side of the gantry. NewTom 5G – Installation Manual...
  • Page 7 8. Removing the posterior “Plastic Ring” (97465003) Unscrew the M4x20 self-tapping screw located on the bottom side of the Plastic Ring. 9. Unhook the Plastic Ring from the 4 back inserts (there are no cables connected to the posterior ring). NewTom 5G – Installation Manual...
  • Page 8 Pull back the control panels and emergency button cables through the dedicated holes on the Anterior Thermoformed Carter (see following picture). Slide out the Anterior Thermoformed Carter from the 4 spacers and store in a safe place. NewTom 5G – Installation Manual...
  • Page 9 13. Remove the block-chassis plate by unscrewing the two M6x20 socket caps screws that hold the plate to the main structure. 14. Unlock the counterweight of the cable chain by removing the M8x80 hex screw. NewTom 5G – Installation Manual...
  • Page 10 The lifting bars include references for a correct positioning (verify they are not positioned below the electronic plate). WARNING: It is very important that the lifting bars are correctly positioned on both the right and left side in order to ensure the device to be balanced during the lifting process. NewTom 5G – Installation Manual...
  • Page 11 19. Slowly lift the device by equally screwing the four ”T” shaped lifting screws, until the wood spacer supports can be removed. Be careful to do not tilt too much the equipment during the lifting process. NewTom 5G – Installation Manual...
  • Page 12 21. Slowly lower the device by equally unscrewing the 4 ”T” shaped lifting screws, until the it rest on the wheels. Be careful to do not tilt too much the equipment while lowering it. 22. Remove the ”T” shaped lifting screws, the plastic feet, the junction bars and the lifting tubular bars. NewTom 5G – Installation Manual...
  • Page 13: Moving The Equipment

    Once the machine rests on the wheels (without any cover mounted) it can be carefully moved to the final position. WARNING: In case the device needs to travel through a ramp, move it down sideway. Maximum admitted inclination is 10%. 1-10 NewTom 5G – Installation Manual...
  • Page 14 Kg (2204 lb) capacity, secured to the front and rear side of the main structure as shown in the following picture. Alternatively four M12 threaded holes are provided in order to mount 4 lifting rings (see following picture). NewTom 5G – Installation Manual 1-11...
  • Page 15: Patient Table Inspection And Unpacking Instructions

    1 M12x140 hex screw 99934441 – SUPPORT FEET 1.3 Patient table inspection and unpacking instructions For unpacking, moving and preparing the patient table for the installation please refer to the provided “Patient Table Installation Manual”. 1-12 NewTom 5G – Installation Manual...
  • Page 16: Mounting And Connecting The Equipment

    M6x20 socket caps screws, eight M6x24 washers and eight M6x18 washers. CAUTION: Do not use the spacers designed for centering the posterior carter, to lift or move the device. Remove the surface protection film from the “Posterior Thermoformed Carter”. NewTom 5G – Installation Manual...
  • Page 17 2. Mount the Input Main Switch plate fixing it with four M4x20 socket caps screws and four M4 washers (see next picture). 3. Mounting the “Anterior Thermoformed Carter” (97465004) Run the control panels and emergency button cables through the dedicated holes on the Anterior Thermoformed Carter (see following picture). NewTom 5G – Installation Manual...
  • Page 18 Remove the surface protection film from the “Anterior Thermoformed Carter”. 4. Mounting the “Posterior Plastic Ring” (97465003). Lean the Plastic Ring to the 4 Bollhoff rubber inserts and press it. Tight the M4x20 self-tapping screw located on the bottom side of the Plastic Ring NewTom 5G – Installation Manual...
  • Page 19 (specific label are stuck on each connector). Once the device is turned on, “Power ON” led on the control panels must be lighted with green color. In case “Power ON” led is yellow, connection is reversed. NewTom 5G – Installation Manual...
  • Page 20 Connect connectors C4F, C5F, C6M, C7F located on the front side of the scanner with the corresponding C4M, C5M, C6F, C7M connector of the patient table. Tie the cables to the provided cable tie mount and verify they won't interfere with the rotating frame of the scanner. NewTom 5G – Installation Manual...
  • Page 21 Fix the plastic by tighting the M4x20 hex socket screw located on the left side of the Front Panel Thermoformed Carter. M4x20 hex screw Remove the surface protection film from the Front Panel Thermoformed Carter. NewTom 5G – Installation Manual...
  • Page 22: Connecting The Equipment

    Once the equipment has been installed a few tests must be performed in order to verify the system functionality before calibrating the device. Refer to the “Service Manual” - Par. “Testing the Equipment” in order to execute the Electrical Safety Checks and other equipment tests. NewTom 5G – Installation Manual...
  • Page 23: Device Calibration

    5. Arrange the cables that connect the machine with patient table and the computer. Cable have to be sheltered using surface raceways or cable protectors, and should be placed away from walk areas in order to avoid people to trip over it. NewTom 5G – Installation Manual...
  • Page 24 QA report and store with the other registrations of the device. ONLY FOR USA: Upon completion of an installation, please fill out and review the manufacturer’s “Installation checklist” (code 97050872) that can be found on the Disk documentation. NewTom 5G – Installation Manual...
  • Page 25 NEWTOM™ 5G is a commercial trademark of CEFLA s.c. All other products and brand names are registered trademarks or trademarks of their respective companies. NEWTOM™ 5G is manufactured by: CEFLA s.c. Phone: +39 045 8202727 Fax +39 045 8203040 e-mail: info@newtom.it...

Table of Contents