Tyco kENDALL KANGAROO ePump Operation And Service Manual

Tyco kENDALL KANGAROO ePump Operation And Service Manual

Enteral feeding pump
Table of Contents

Advertisement

Quick Links

tyco/ Healthcare
kENDALL
KANGAROO
Enteral Feeding Pump
Operation and Service Manual
Enteral Feeding Pump — Operation and Service Manual
Nutripompe — Manuel d'utilisation et d'entretien
Pumpe für die enterale Ernährung — Betriebs- und Serviceanleitung
Pompa di alimentazione enterale — Manuale operativo e di manutenzione
Bomba para alimentación enteral — Manual de operación y servicio
Enteral matningspump — Användar- och servicemanual
Enterale voedingspomp — Handleiding voor bediening en onderhoud
Bomba de alimentação entérica — Manual de funcionamento e assistência
Enteraalinen ravitsemuspumppu — Käyttö- ja huolto-opas
Pumpe til enteral ernæring — Betjenings- og servicehåndbog
Αντλία εντερικής σίτισης — Εγχειρίδιο λειτουργίας και σέρβις
Pumpa pro enterální výživu — Provozní a servisní příručka
Enterális táplálópumpa — Kezelési és karbantartási kézikönyv
Насос для энтерального питания — Руководство по эксплуатации и техническому обслуживанию
Pompa żywienia dojelitowego — Instrukcja obsługi i serwisowania
Enteral Besleme Pompası — Operasyon ve Servis Kılavuzu
Enteral ernæringspumpe — Bruker- og vedlikeholdshåndbok
Rx
ONLY
0123
™ Trademark of Tyco Healthcare Group LP or its affiliate.
™*SPRAY-NINE is a trademark of Spray-Nine Corporation.
™*PHISOPHEX is a trademark of Smith Kline Beecham Corp.
™*HIBICLENS is a trademark of Tubifoam Ltd.
™*VESTA-SYDE is a trademark of Steris, Inc.
TYCO HEALTHCARE GROUP LP • MANSFIELD, MA 02048 • MADE IN U.S.A. • © 2007 TYCO HEALTHCARE GROUP LP
ALL RIGHTS RESERVED • 070105 • PRODUCT INFORMATION IN U.S. 1-800-962-9888 • www.tycohealthcare.com
EC REP TYCO HEALTHCARE U.K. LTD • GOSPORT PO13 0AS, U.K.
182433
e
Pump

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the kENDALL KANGAROO ePump and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tyco kENDALL KANGAROO ePump

  • Page 1 ™*HIBICLENS is a trademark of Tubifoam Ltd. ™*VESTA-SYDE is a trademark of Steris, Inc. TYCO HEALTHCARE GROUP LP • MANSFIELD, MA 02048 • MADE IN U.S.A. • © 2007 TYCO HEALTHCARE GROUP LP ALL RIGHTS RESERVED • 070105 • PRODUCT INFORMATION IN U.S. 1-800-962-9888 • www.tycohealthcare.com EC REP TYCO HEALTHCARE U.K.
  • Page 2: Table Of Contents

    english Thank you for purchasing the KANGAROO ePump™ Enteral Feeding Pump. With proper care, this device will provide you with years of precision service. Table of ConTenTs Page section I — General Information ................1 section II —...
  • Page 3 Table of ConTenTs Selecting Continuous or Intermittent Mode ............... . 13 Continuous Mode (Adjust Feed) .
  • Page 4 ................. 40 This product contains software solely owned by Tyco. Tyco grants the user a non-exclusive, limited license to use the software according to the operating instructions. A copy of the license can be obtained from Tyco. Enteral Feeding Pump...
  • Page 5: Section I - General Information

    section I – General Information The KANGAROO ePump enteral feeding pump is a simple-to-use, precision enteral feeding pump. It is easily programmed to provide patients with either continuous or intermittent feeding, and can provide automatic flushing capability when used with KANGAROO ePump Feed &...
  • Page 6 Status Line Menu Selections Status LEDs Input Settings Menu Selection Buttons Output Totals Power Button Graphic Display Battery Status Front Integrated Handle Feeding Set Cap Storage Area Pole Clamp Attachment Point A/C Adapter Port Serial I/O Port Door Battery Compartment Back figure a.
  • Page 7: Section Ii - Safety And Warnings

    figure b. KanGaRoo ePump Pump set loading area. section II — safety and Warnings CaUTIon: U.S. federal law restricts the sale of this device to physicians or to their direct representatives 1. Read this booklet thoroughly before using the KANGAROO ePump enteral feeding pump. 2.
  • Page 8: Section Iii - Icon Identification

    12. This device is designed to minimize the effects of uncontrolled electromagnetic interference and other types of interference from external sources. Avoid use of other equipment that may cause erratic operation or degradation in the performance of this device. 13. WaRnInG: The serial I/O port (see Figure 1A) is intended only for use by the manufacturer. Any accessory equipment that can be connected to the DB9 Serial I/O port, and which does not comply with the equivalent safety requirements of this equipment, may lead to a reduced level of safety of the pump.
  • Page 9: Section Iv - Initial Setup

    eZMoDe Indicator Indicates that EZMODE feature is turned on. Communication Indicato Indicates that communication feature is turned on Volume to be Delivered Indicator Indicates that VTBD feature is turned on. Keep Tube open Indicates that Keep Tube Open feature is turned on. section IV —...
  • Page 10: Battery Setup

    figure b. battery setup The battery pack is fully charged before shipping, and is left unconnected to optimally preserve battery life. WaRnInG: The battery should be connected before using the pump. It is also recommended that the battery charge be “topped off” before battery-only operation is utilized. The battery pack will charge continuously whenever the pump is plugged into a wall outlet, including during normal use of the pump with A/C power.
  • Page 11: Section V - Instructions For Use

    figure . attaching and using the Pole Clamp or Cord Clip. If cord restraint is preferred but use of the pole clamp is not desired, a cord restraint clip is provided with the KANGAROO ePump enteral feeding pump. Using the pole clamp mounting bolt, follow the pole clamp assembly instruction to attach the cord clip (Refer to Fig.
  • Page 12: General Startup

    • Grasp finger tab on valve and insert into left pocket (1). • Grasp black ring retainer and gently stretch tubing around rotor (2). Pull up on retainer and insert into right pocket (3). • Press down on finger tab to ensure that valve is fully seated. Finger tab should align with locating rib. •...
  • Page 13: Battery Power Operation

    battery Power operation If A/C power is not available to the pump, or if A/C power is interrupted, the pump will automatically operate on backup battery power. The built-in battery recharges any time the pump is plugged into an outlet. A fully-charged, new battery will supply 15 hours of backup power at 125 mL/hr before requiring recharging.
  • Page 14: Loading Pump Sets

    loading Pump sets` The KANGAROO ePump enteral feeding pump will indicate LOAD A SET in the screen’s status line if a Pump Set is not installed. A blinking icon of a Pump Set will also appear in the upper left corner of the screen. Figure 5A shows the screen for continuous feeding mode and Figure 5B shows the screen for intermittent feeding mode (intermittent feeding mode not available in EZMODE).
  • Page 15: Prime Pump

    figure a. opening menu figure b. opening menu for Continuous feed mode for Continuous feed mode with a feed-only set. with a feed & flush set. figure C. opening menu figure D. opening menu for Intermittent feed mode with a for Intermittent feed mode feed-only set.
  • Page 16: Hold-To-Prime

    Press sToP to cancel aUTo PRIMe. When auto-priming is completed, the status line will show AUTO PRIME COMPLETE and will no longer show the aUTo PRIMe option. Be sure that the line(s) are fully primed. If not, use the hold-to-prime option(s) to complete the priming, as described below. Hold-to-Prime The hold-to-prime options allow for precise interactive control of the priming process.
  • Page 17: Selecting Ezmode

    0-400mL/hr as defined by the user until manually stopped. It has no bolUs, flUsHInG, RUn MoDe sCReen loCK, or aUToResUMe capability and displays no HIsToRy information. Turning on eZMoDe will automatically force the unit out of the InTeRMITTenT (bolUs feeD) mode if set. Although the Continuous Mode feed VTBD will be set to 0 while eZMoDe is enabled, the previous value of the feed VTbD will be stored in flash memory and recalled when “eZMoDe”...
  • Page 18: Continuous Mode (Adjust Feed)

    Select ConTInUoUs/InTeRMITTenT under the MORE OPTIONS menu, Figure 10A. Then press ConTInUoUs MoDe InTeRMITTenT MoDe from the seleCT MoDe menu, Figure 10B. Press Done to exit. figure 0a. MORE OPTIONS menu. figure 0b. SELECT MODE menu for continuous or intermittent mode selection.
  • Page 19: Intermittent Mode (Adjust Bolus)

    Press flUsH InTeRVal in Figure 12A to define the time interval between starts of flushing. Press the buttons in Figure 12C to program the time interval from 1 to 24 hours in increments of 1 hour. Press enTeR (top button) to exit the menu. The pump will automatically limit flushing settings which exceed pump capabilities to deliver.
  • Page 20: Intermittent Mode Feeding - Bolus Max

    noTe: If the NUMBER OF BOLUSES is reprogrammed during a feeding (from HOLD mode), the pump will restart the bolus feeding and will deliver all the boluses as defined by the new setting. figure a. ADJUST BOLUS menu. figure b. setting the bolus Rate. figure C.
  • Page 21: Run

    figure b. setting the flush figure C. setting the flush Time figure a. ADJUST FLUSH Volume. Interval. menu, intermittent mode. note: The nature of two intermittent processes, periodic bolus feeding and periodic flushing, is such that occasional conflicts can arise where each process needs to be running at the same time. The flushing process is assigned precedence over the feeding process for Feed &...
  • Page 22: Kto

    figure b. KTo. figure a. RUNNING mode screen for continuous feed mode. figure . Program locked screen, which indicates the pump is in loCK seTTInGs mode. (Not Available in EZMODE) The Keep Tube Open (KTo) function within the KANGAROO ePump enteral feeding pump will help prevent a blockage of the feeding set by moving the feeding solution periodically within the tube.
  • Page 23: Hold

    Hold HolD while it is RUNNING, such as in Figure 15A. The status line will indicate Pump operation can be paused by pressing HOLDING and the yellow LED indicator will be lit up to give a quick visual indication of an informational status in a darkened room. Note: the pump’s alarm will sound if it has been left HOLDING for 10 minutes without further input.
  • Page 24: Flush Now

    flush now (Not Available in EZMODE) During the RUNNING mode, the pump can be diverted to immediately perform a flush (flush on demand) by pressing FLUSH NOW in the RUNNING menu, input a desired flush volume, then press enTeR. See Figure 15A. When flUsH noW is pressed, the screen will prompt for the volume to be immediately flushed, and will show the previously programmed flush volume as default but may be adjusted to the users desired volume.
  • Page 25: Language Selection

    figure 0. feed and flush totals for up to  hours of previous history, excluding data from the current hour. language selection lanGUaGes in the MORE OPTIONS menu to change the preferred language for the screen interface. Press Continuous/Intermittent Mode (Not Available in EZMODE) Press ConTInUoUs/InTeRMITTenT in the MORE OPTIONS menu to access the SELECT MODE menu, Figure 10B.
  • Page 26: Biotech Options

    CeRT InTV indicates the number of times the pump has been powered on since the last re-certification. See Section VI for details of re-certifying the pump. bioTech options figure . bioTech option screen, with lock setting, eZMoDe, and Communications features activated. lock settings feature —...
  • Page 27: Section Vi - Re-Certification Of Performance

    Press Done to exit the bioTech menu. To re-enter this menu screen, power down the pump and then power it up again and hold the top button, as described above. section VI – Re-Certification of Performance system Performance Re-Certification A series of self-diagnostic checks can be run to re-certify pump performance. It is recommended that this re-certification procedure be run at least once per year, or any time the pump is suspected of having improper performance.
  • Page 28: Section Vii - Cleaning

    section VII — Cleaning Cleaning should be performed as needed. It may also be desirable to define cleaning intervals based on knowledge of the environment in which the pump is used. Only personnel trained in the cleaning of medical devices should perform cleaning. CaUTIon: Do not immerse pump or power cord in water or other cleaning solution;...
  • Page 29: Section Viii - Battery Replacement

    Re-certification may be done at the user’s Biomedical Engineering Department, an outside service, or by Tyco Healthcare Group LP Factory Service. To arrange for Tyco Healthcare Group LP Factory Service in the US, call 1-800-448-0190. In Canada, call 1-877-664-TYCO(8926). Outside of the US and Canada, please contact your local Customer Service for more information.
  • Page 30: Section Ix - Error/Warning/Informational Screens And Troubleshooting

    . Installation of battery Pack. WaRnInG: USE OF A BATTERY PACK NOT SUPPLIED BY TYCO HEALTHCARE GROUP LP CAN BE DANGEROUS AND VOIDS ALL WARRANTIES AND PERFORMANCE SPECIFICATIONS. The battery will charge continuously whenever the pump is plugged into a wall outlet. Eight hours of charging is required to fully recharge the Battery Pack.
  • Page 31: System Error

    system error (Fixed Audible Volume) The system error screen is the most general form of error, Figure 25. The only way to exit from a System Error is to power down. No ConTInUe option is allowed because of the severity of the error. An error number is also displayed on the screen, for reference purposes.
  • Page 32: Hold Error

    Turn the power off and back on to try to clear the error. If the error cannot be resolved in a timely manner, press PoWeR to stop operation of the pump and put a different pump into service. Hold error (Adjustable Audible Volume) The HolD eRRoR screen will appear if the pump has been inactive, without input, for more than 10 minutes.
  • Page 33: Flush Error

    figure . feed error screen. flush error (Adjustable Audible Volume) The flUsH eRRoR screen appears when the flushing solution is no longer being delivered because the flush bag is empty or because of a clog between the pump and flush bag. Check the flush line to find the occlusion causing the blockage. If the occlusion cannot be cleared, load a new Pump Set, prime it, and restart the feeding, Figure 29 If the error still cannot be resolved, press PoWeR to stop operation of the pump and put a different pump into service.
  • Page 34: Battery Low

    figure . Pump set Dislodged error screen. battery low (Fixed Audible Volume) The baTTeRy loW screen appears and the alarm beeps continuously when the battery needs to be recharged. There is approximately 15 minutes of battery life remaining when this screen appears, Figure 32. Plug the power cord in to begin recharging.
  • Page 35: Led Array

    figure . Running screen with the >  HRs of Pump set Usage indicator in upper left of the screen. leD array The pump status LED array on the upper right of the pump gives a quick visual indication of the pump status, especially in darkened rooms.
  • Page 36 feeding formula VTbD 1-3000 mL in 1 mL increments bolus Volume 1-3000 mL in 1 mL increments number of boluses 1-99 bolus Interval 1-24 hours in 1-hour increments flushing solution Dose Range 10-500 mL in 1 mL increments flushing solution Interval Range 1-24 hr in 1 hr increments accuracy ±10% or 0.5 mL/hr, whichever is larger, with bag at 46 cm (18”) above pump, at room temperature 22°...
  • Page 37 • Feed Error • Flush Error • Battery Low alarm Volume Minimum of 70 dBA at 1 meter in maximum volume orientation operating Temperature 10° - 40° C (50° - 104° F) 75% R.H. non-condensing storage Temperature 0° - 50° C (32° - 122° F) 95% R.H. non-condensing Type of Protection against electrical shock Class II, Internally-powered Equipment Degree of Protection against electrical shock...
  • Page 38: Symbols On Pump And Accessories

    symbols on Pump and accessories The following symbols are found on the pump or on the accessories, such as the A/C adapter. Refer to Accompanying Buttons for Selecting Documents Screen Prompts VDE in Europe Power Source Type BF Protection (Degree of 9V DC 1.5 Amp protection against electrical UL in USA...
  • Page 39: Section Xi - Customer Service

    1. Call Customer Service for an Authorized Return Number and shipping instructions, using the appropriate phone number below: 2. Pack the instrument carefully and ship the insured parcel to: United states Canada Tyco Healthcare Group LP Tyco Healthcare Canada 98.6 Faichney Drive 7300 Trans Canadian Highway...
  • Page 40: Battery Pack

    Top Door Hinge Hinge Lower Hinge Lower Door Hinge figure . blue Door Replacement. battery Pack See Section VIII for full instructions on replacing Battery Pack. During long-term non-usage or storage (greater than 9 months) of the pump, battery discharge and deactivation may tend to occur. It is recommended that the battery be disconnected during this time. The battery may need to be charged and discharged several times to restore optimal capacity.
  • Page 41: Section Xiii - Service Part Numbers

    section XIII – service Part numbers To place an order for parts, or if technical assistance is required, call customer service. The KANGAROO ePump enteral feeding pump contains a limited number of serviceable parts, Figure 37. User maintenance is to be performed only by appropriately qualified technical personnel.
  • Page 42: Section Xiv - Warranty

    Customer the purchase price for the defective part or product. Dated proof of original purchase will be required. Tyco Healthcare Group LP does not assume any liability for loss arising from unauthorized repair, misuse, neglect, or accident.
  • Page 43: Section Xv - Electromagnetic Conformity Declaration

    section XV – electromagnetic Conformity Declaration The KANGAROO ePump enteral feeding pump has been built and tested according to UL60601-1, E189131 CSA-C22.2 No.601.1-M90, and EN60601-1-2 Standards. The KANGAROO ePump enteral feeding pump is intended for use in the electromagnetic environment specified below. The user of the pump should assure that it is used in such an environment.
  • Page 44: Section Xvi - Accusystem

    Tyco Healthcare Group LP KANGAROO ePump AccuSystem√ feeding sets. The use of generic feeding sets or other feeding sets not produced by Tyco Healthcare Group LP is not supported or sanctioned by Tyco Healthcare Group LP. The use of unauthorized KANGAROO ePump feeding sets could jeopardize the accuracy of the KANGAROO ePump enteral feeding pump.
  • Page 45 ™ Trademark of Tyco Healthcare Group LP or its affiliate. TYCO HEALTHCARE GROUP LP • MANSFIELD, MA 02048 • MADE IN U.S.A. • © 2007 TYCO HEALTHCARE GROUP LP • ALL RIGHTS RESERVED • 070118 • IN U.S. 1-800-962-9888 • www.tycohealthcare.com TYCO HEALTHCARE U.K.
  • Page 46 ™*SPRAY-NINE is a trademark of Spray-Nine Corporation. TYCO HEALTHCARE GROUP LP • MANSFIELD, MA 02048 • MADE IN U.S.A. • © 2007 TYCO HEALTHCARE GROUP LP • ALL RIGHTS RESERVED • 070118 • IN U.S. 1-800-962-9888 • www.tycohealthcare.com ™*PHISOPHEX is a trademark of Smith Kline Beecham Corp.

Table of Contents