Hide thumbs Also See for Mystic Tan KYSS MT-6500:

Advertisement

Quick Links

Mystic Tan Kyss™ Maintenance Guide
Maintenance Guide to the
Mystic
Tan KYSS (MT-6500)
TM
220V 50/60 Hz
www.sunless.com
Maintenance Guide
Version 1.0
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mystic Tan KYSS MT-6500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sunless Mystic Tan KYSS MT-6500

  • Page 1 Mystic Tan Kyss™ Maintenance Guide Maintenance Guide to the Mystic Tan KYSS (MT-6500) 220V 50/60 Hz www.sunless.com Maintenance Guide Version 1.0...
  • Page 2 __________________ Installation Date: ____ / ____ / ______ Mystic 6500 Sunless, Inc. 8909 S Freeway Drive Macedonia, OH 44056 Tech Support: (855) 450-3500 For Support with Sales, Solutions, Lotions, and Products: (888) 974-9977 ©Copyright 2016 Sunless, Inc. All Rights Reserved...
  • Page 3: Table Of Contents

    Mystic Tan Kyss™ Maintenance Guide Table of Contents Maintenance Schedule for the Mystic Kyss ..................4 Daily Maintenance ........................4 Line Purge ..........................4 Clean Exhaust Filter ......................5 Clean the Drain Filter ......................6 End of Day Maintenance ....................... 7 Daily Maintenance Checklist ....................
  • Page 4: Maintenance Schedule For The Mystic Kyss

    Mystic Tan Kyss™ Maintenance Guide Maintenance Schedule for the Mystic Kyss Every machine and complex piece of equipment requires maintenance to perform properly. Just like your car needs an oil change to keep the engine running smoothly, the Mystic Kyss is a complex piece of equipment with a multitude of different systems working together.
  • Page 5: Clean Exhaust Filter

    Mystic Tan Kyss™ Maintenance Guide Clean Exhaust Filter Clean the inner exhaust filter, as well as the inside and outside of the filter housing. Make sure to have the spare filter clean, dry, and ready to insert. Avoid any abrasive clothes or cleaners.
  • Page 6: Clean The Drain Filter

    Mystic Tan Kyss™ Maintenance Guide Clean the Drain Filter Clean the drain filter and sump basin to remove excess sediment and ensure no obstructions form. The drain filter cover will simply snap off, providing access to the filter and sump basin. Regularly neglecting the drain filter can lead to clogging of the sump and failure to drain properly.
  • Page 7: End Of Day Maintenance

    Mystic Tan Kyss™ Maintenance Guide End of Day Maintenance After purging the lines, cleaning the exhaust filter, and the drain filter, take the time to close the booth down correctly.  Wipe down the booth with clean, warm water and a soft, nonabrasive cloth. If there are any stains, simply use a few drops of Dawn or other mild cleaner in warm water to remove.
  • Page 8: Daily Inspection Checklist

    Mystic Tan Kyss™ Maintenance Guide Daily Inspection Checklist Perform the Line Purge process in the Staff > Tools screen using clean, warm water until the line runs empty of water. Check the Air Pressure value displayed by the Purge function. If the PSI value is outside the range of 18.5 –...
  • Page 9: Weekly Maintenance

    Mystic Tan Kyss™ Maintenance Guide Weekly Maintenance The following actions are only suggested once per week to keep the booth operating like new. Repeatedly neglecting the weekly maintenance can lead to a visible accumulation of solution particles and a reduced ability to properly filter the booth. Clean Top Exhaust Filter Clean the top exhaust filter to avoid saturation with solution and to ensure proper evacuation and filtration of solution particles during the spray session.
  • Page 10: Weekly Maintenance Checklist

    Mystic Tan Kyss™ Maintenance Guide Once the top exhaust filter is removed, take it to a sink and wash with warm water. Only once the filter has been allowed to fully dry should it be reinserted into the ceiling. Do not run the booth with the top exhaust filter removed.
  • Page 11: Clean Float Switch Plate And Sump Basin

    Mystic Tan Kyss™ Maintenance Guide Clean Float Switch Plate and Sump Basin An in-depth cleaning of the float switch plate and sump basin should be performed monthly and extends beyond rinsing the filter. Repeated failure to perform this action could lead to clogging of the sump basin and sticking float sensors, which could register as a booth fault and cause problems when trying to run a session.
  • Page 12: Clean Heater And Compressor Filters

    Mystic Tan Kyss™ Maintenance Guide Clean Heater and Compressor Filters Clean the intake filters to ensure the air coming into the booth is properly filtered, both for comfort and to avoid particles entering the booth. Repeatedly neglecting this maintenance can lead to reduced air intake and particles being introduced through the air vents.
  • Page 13: Monthly Maintenance Checklist

    Mystic Tan Kyss™ Maintenance Guide Monthly Maintenance Checklist Perform all daily checklist activities. Perform all weekly checklist activities. Remove bottom plate by pulling up on the handle. Clean any residue from the panels. Use a nonabrasive cloth and Dawn or other mild detergent/ cleaner for all components. Carefully remove the float switch plate without damaging the floats.
  • Page 14: Appendix 1: Adjusting The Air Pressure

    Mystic Tan Kyss™ Maintenance Guide Appendix 1: Adjusting the Air Pressure There are two main reasons you may notice a deviation in the recommended compressor PSI: inefficient tanning results from too much or too little air pressure or from performing regular maintenance and inspections of your unit.
  • Page 15: Appendix 2: Diagnostic Output Tolerances

    Mystic Tan Kyss™ Maintenance Guide To adjust the air compressor, open either the Staff > Black Cap- hold Tools > Purge option OR the Technical > Diagnostic in position while Outputs > Compressor option (both show PSI value). tightening silver Use this to monitor the current PSI output from the locknut compressor.
  • Page 16 Mystic Tan Kyss™ Maintenance Guide Exhaust Fan- Value is either OFF (0) or ON (1). During ON the Exhaust Fan should run. Wash Solenoid- Value is either OFF (0) or ON (1). Activation should toggle between states. Start Lamp- Value is either OFF (0) or ON (1). During ON the start sensor should illuminate. In the ON state, the start sensor does not blink.
  • Page 17: Appendix 3: Quick Start Staff Guide

    Mystic Tan Kyss™ Maintenance Guide Appendix 3: Quick Start Staff Guide A familiarity with the features and operations is essential for long term sustainability of the unit, but if you just want to run a quick session, this is the section to get you started. Select a Solution and Myxes Select a solution to be applied.
  • Page 18: Prepare The Booth

    Prepare the Booth While preparing the solution, or after it is prepared, start the booth to begin the warm up cycle so the tanner has a comfortable and inviting environment when entering.
  • Page 19 Mystic Tan Kyss™ Maintenance Guide While the booth is preparing, place the sealed cartridge into the receptacle upside-down. The back of the cartridge with the groove will face toward the back, and the front graphic will face toward the front. Once inserted, push the receptacle closed.
  • Page 20: Start The Session

    Mystic Tan Kyss™ Maintenance Guide Start the Session Once the booth has reached temperature, the solution cartridge is added, and solution is in the reservoir start switch will begin flashing green inside the booth. The user simply needs to enter the booth, close the door, stand on the two footpads, and wave a hand in front of the flashing sensor.