Summary of Contents for SureLife Classic

  • Page 1 Arm Blood Pressure Monitor SYS . mmHg DIA . mmHg Pulse /min Classic Model...
  • Page 2: Safety Precautions

    SAFETY PRECAUTIONS • Infants, young children or individuals who cannot express their consent are not suitable to take blood pressure measurement. • Individuals with serious arteriosclerosis are not suitable to take blood pressure measurement. • Blood pressure readings may change in case of pregnancy. Pregnant women should consult their doctor before taking measurement.
  • Page 3 QUICK START GUIDE Avoid smoking, eating, drinking ca einated drinks or exercising for 30 minutes before taking measurement. 1. Sit upright in a chair with both feet on the oor. 2. Remove tight tting clothing from your upper arm along with any thick clothing.
  • Page 4 OVERVIEW Monitor SYS . mmHg DIA . mmHg Pulse /min Cu Outlet Memory Recall (Up) Power (Start) Features • One Touch Operation • 99 Total Memory • Irregular Heartbeat Detector • Auto-o Power Saving Feature • Operated by 4 AA batteries (AC Adapter optional)
  • Page 5: Package Contents

    Display Systolic Diastolic Memory Pulse Low Battery Pulse Symbol Indicator Memory No. (1-99 readings) Package Contents SYS . mmHg DIA . mmHg Pulse /min Main Unit Arm Cu Instruction 4 x AA Manual Alkaline Batteries...
  • Page 6: Battery Installation

    PREPARATION 2.1 Battery Installation 1. Pull and lift on the lock to remove the battery cover. 2. Insert 4 AA batteries with the polarities in the correct direction. 3. Replace the battery cover. Press it lightly until the lock securely clicks into place.
  • Page 7: Taking Measurement

    TAKING MEASUREMENT Note: • Avoid smoking, eating, drinking any ca einated drinks or exercising for 30 minutes before taking measurement. • Do not move or talk during measurement. 3.1 Sitting Correctly 1. Relax 2. Sit upright in a chair with both feet on the oor. 3.
  • Page 8: Heartbeat Readings

    3.3 Taking Measurement 1. Press the “ ” button. The cu will automatically in ate and the measurement will start. 2. When the measurement is complete, the cu will automatically de ate and your systolic and diastolic pressure values and pulse rate will display.
  • Page 9: Irregular Heartbeat

    Irregular Heartbeat This unit has a unique feature that alerts user of irregular heartbeat detection during measurement. Note: An irregular heartbeat is de ned as a heartbeat rhythm that has a variation of more than 25% from the average rhythm detected during measurement.
  • Page 10 Regular but Below Normal Heartbeat If the monitor detects a pulse rate below 60 beats per minute during measurement, the monitor will display the pulse value and “LO” symbol alternately. Example: (58 / LO) Regular but Above Normal Heartbeat If the monitor detects a pulse rate above 100 beats per minute during measurement, the monitor will display the pulse value and “HI”...
  • Page 11: Memory Functions

    MEMORY FUNCTIONS After measurement, the last set of measured values will be saved automatically after measurement when the unit is turned o by pressing “ ” button or by automatic power o after 3 minutes. 4.1 View Past Readings 1. Press the “M” button to enter memory function. 2.
  • Page 12: Troubleshooting

    TROUBLESHOOTING Problem Cause Solution No display when Have the batteries Replace new you press the run out? batteries. Power/Start Are the battery Re-align batteries button polarities wrong? in correct polarities. Check if the cu is “Err P” displayed Fail to in ate properly connected.
  • Page 13: Storage And Maintenance

    STORAGE & MAINTENANCE • Keep the unit away from direct sunlight, extreme temperatures, humidity or moisture • Use a dry, soft cloth to clean the unit, or if desired, use a cloth lightly dampened with water. • Do not use alcohol, benzene, thinner or other volatile liquids to clean the unit.
  • Page 14: Specifications

    SPECIFICATIONS Model No. Classic (SL-BA201) Measurement Method Oscillometric Measurement Range Pressure: 20 – 280 mmHg Pulse Rate: 40 – 195 beats/min Accuracy Pressure: +/- 3 mmHg Pulse Rate: +/- 5% In ation Pump driven Pressure Detection Semi-Conductor Power Supply 4 x AA batteries...
  • Page 15: Warranty

    WARRANTY A Full 5-Year Warranty on Your Monitor The SureLife® Arm Blood Pressure Monitor, excluding the arm cu , is warranted to be free from defects in materials and workmanship within 5 years from the date of purchase. A Full 1-Year Warranty on Your Arm Cu The arm cu is warranted to be free from defects and workmanship within 1 year from the date of purchase.
  • Page 16 MHC Medical Products, LLC 8695 Seward Road Fair eld, Ohio 45011 Made in China to MHC Medical Products’ speci cations. Package design © 2010 SureLife® is a trademark of MHC Medical Products, LLC. Manufactured in accordance with FDA and International Standards 0123 AD-121015.3...