IMC-300MKII Controller to IMC-x00 Controller(s) Communication Wiring ..........22 A2-4.2 RS-485 Terminators ............................23 APPENDIX 3 ....................................1 APPENDIX 4 ....................................1 .................................... 1 YNTAX ..............................1 PERATIONAL XAMPLE APPENDIX 5 ....................................2 APPENDIX 6 ....................................5 APPENDIX 7 ....................................11 Converging Systems Inc. Page 2 Rev.5.0.0...
Page 3
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est confirme á la norme NNB-003 du Canada Models 100-240VAC versions IMC-300MKII-EM Master Controller IMC-300MKII-SL Slave Controller Ratings: Input: IMC-300MKII-EM: 100-240 VAC, 50-60 Hz, Single Phase IMC-300MKII-SL: 100-240 VAC, 50-60 Hz, Single Phase Load Capacity: ALL Models: 2.1A (1/3 HP) Documentation Revision History Revision Date Description 5.0.0...
Description: The Masking Director Controller family (IMC-300MKII-EM and IMC-300MKII-SL) are designed to control residential and commercial bi-directional blind, drapery and projection screen single phase, bi-directional AC motors (three wire motors--open, close, neutral connections). The IMC-300MKII-xx series of Controllers can be controlled through a number of remote control devices, including...
There are three motor ports on the MD-300. Motor Ports 1 and 2 are equipped with a built-in (accompanying) digital encoding circuit. Motor Port 3 is for analog-type motors (without digital encoding provisions). AC Motor wires should be plugged into appropriate ports. Converging Systems Inc. Page 5 Rev.5.0.0...
Leave AC Power OFF to system until requested to turn ON. Communication/ Low Voltage and CS-Bus Wiring Instructions Multiple communication I/Os are available within the IMC-300MKII-EM controller. Typically, only form of communication should be used. The choice depends upon your specific integration platform. It is recommended that for most systems, Internet Protocol (IP) should be used.
328 feet (100 meters). Plug one end of the above cable into the IP Connector on the IMC-300MKII-EM Controller and the other end to a network switch through which control to a remote integration platform is connected.
In the case of a multiple IMC-300MKII-xx controllers (or alternative CS-Bus controllers), only one connection to the RS-232C Connector on the master controller (the IMC-300MKII-EM Controllers) is supported. CS-Bus Connections (for connection to keypads and to additional IMC-100MKII-xx controllers).
When connecting an IMC-x00 compatible keypad to an IMC-300MKII-EM (i.e. BSMK-2110-B), connect the first keypad to the IMC-300MKII-EM’s Output (Port 0). If you desire to connect a second compatible keypad, secure an optional Device Insertion Module (DIM-2F-1M) and plug the DIM-2F/1M into Port 0 on the MD-300 and plug both keypads into the available Female ports.
Should your installation only require such functionality, please proceed within this section. However, if your installation requires additional customization not available with the information contained within this section, please consult Converging Systems Now follow the below steps: Factory Programming-DIP Switch Programming Certain often used templates have been re-programmed into the IMC-300MKII controller.
Page 11
Provided the DIP switches have been set to a valid programmed setting, pressing an appropriate button on a BSKP-2112 keypad should enable quick testing of the Masking Director System. Enhanced testing can be performed using the e-Node Pilot application. Converging Systems Inc. Page 11 Rev.5.0.0...
The factory default for these six buttons is (Zone1/Group 1) for the first button marked “1,” sequencing to (Zone 1/Group 6) for the last button marked “6” (i.e. the Zones are always the same if the factory defaults are left unmodified). Converging Systems Inc. Page 13 Rev.5.0.0...
Page 14
All motors should be send to home first using individual controls for Motor A, Motor B (if present). Then the Calibrate command should be invoked. This auto-calibrates the IMC-300 MKII to know the location of all motors in their Converging Systems Inc. Page 14 Rev.5.0.0...
Page 15
Mode Select Button Default from Factory BSKP-2112 Mode BSKP-2110 (Bric I mode) IMC-100 Mode Infrared Receiver. This is a build-in Infrared Receiver to be used with compatible Infrared remote. Converging Systems Inc. Page 15 Rev.5.0.0...
(fully UP or fully DOWN) position. BSKP-2050 only Specific Activity Buttons-Channel 2 (UP/DOWN). The right pair of UP/DOWN buttons activates one or connected motor controllers designated as Channel 1 to move those motor(s) in the selected direction. In the Converging Systems Inc. Page 16 Rev.5.0.0...
Page 17
(fully UP or fully DOWN) position. Button. Depress this button anytime while a motor moving and the motor will stop. Infrared Receiver. This is a built-in Infrared Receiver to be used with compatible Infrared remote. Converging Systems Inc. Page 17 Rev.5.0.0...
(UP or DOWN) and then release, the motor controller will activate a connected bi-directional motor to travel in that appropriate direction until it reaches its desired (fully UP or fully DOWN) position. Converging Systems Inc. Page 18 Rev.5.0.0...
Converging Systems’ Infrared remotes. Application: Infrared remotes can control of one more intelligent motor controllers linked together. When used in...
Page 20
Toggle button, Motors C/D can be controlled in a dual Masking Director configuration. 12-button only STORE Button Enable the storage of exact motor positions. First select the Store button then a preset number from 1 to 6 Converging Systems Inc. Page 20 Rev.5.0.0...
2110/2116/20302050 keypads. No additional IR support is provided. has a built-in optional IR attachment connector. A2-3 Intelligent Peripheral Connections A2-3.1 CS-Bus to IMC-BSKP-2030 (3 button), IMC-BSKP-2050 (5-button) or IMC-BSKP-2110/2112- (Intelligent Keypads) [Mk II Keypads] Figure 14 Converging Systems Inc. Page 21 Rev.5.0.0...
#1 No Signal #1 No Signal #2 GND #2 GND #3 485- #3 485- #4 485+- #4 485+ #5 5V DC (regulated) #5 5V DC (regulated) #6 9V DC (unregulated) #6 9V DC (unregulated) Converging Systems Inc. Page 22 Rev.5.0.0...
Page 24
The IMC-300MKII supports a range of screen types. For screens which include a door, a special built-in programming scheme exists within device firmware versions 0.17 and later (this is the firmware for the Motor Control portion of the IMC-300MK as opposed to the ethernet/communication front end-firmware). Converging Systems Inc. Page 1 Rev.5.0.0...
Page 25
This sends over the important CALIBRATE command over the CS-BUS to the system which will instruct the unit that all screens and masks are full retracted and in such position the door is safe to close. Converging Systems Inc. Page 2 Rev.5.0.0...
Page 26
• DOWN Dual Toggle • • Masking Chan C EMHV RIGHT 4WSN Toggle • • Chan C DOWN 8 Way STOP • • • Slave LEFT RIGHT 8 way Toggle • • Master DOWN Converging Systems Inc. Page 1 Rev.5.0.0...
Page 27
Director’s Toggle • • • Choice Master DOWN Director’s STOP • • • Choice Slave LEFT RIGHT ABTEMH Door Retract • • • • / Home Converging Systems Inc. Page 2 Rev.5.0.0...
TABLE 2-CS-BUS (ZGN) Commands Command Syntax Motor 1 UP #1.1.1.MOTOR=UP <CR> Motor 2 DOWN #1.1.2.MOTOR=DOWN <CR> Motors Group Move to PRESET 1 #1.1.0.MOTOR=RECALL,1 <CR> Save current position for Motors as PRESET 2 #1.1.0.MOTOR=STORE,2 <CR> Converging Systems Inc. Page 1 Rev.5.0.0...
Page 29
Double click on the (i) Stewart Logo or (ii) the Configuration Tab if present 300 MKII Configuration software (embedded within IMC-300 MKII) controller ENFW-3 Enter Typically and unless otherwise changed, the login password is ADMIN (case sensitive) appropriate -Type in ADMIN and select Logon password Converging Systems Inc. Page 2 Rev.5.0.0...
Page 30
-Run executable. Your file may look similar to this: provided MO (tor firmware) and run unzipped version. -Select from the pulldown box the IP address of the (embedded e-Node) within our IMC- 300MKII device. Converging Systems Inc. Page 3 Rev.5.0.0...
Page 31
Next select the Select button and the firmware will be automatically upgraded. Converging Systems Inc. Page 4 Rev.5.0.0...
Page 32
-Select the View e-Node tab and select the Discover e-Node button. Any IMC- 300MKII connected on the same network will appear as shown. -Select the + mark in front of the e-Node found to expand the menu. Converging Systems Inc. Page 5 Rev.5.0.0...
Page 33
Reference when devices are discovered IF set to ALL OFF Test or similar generic See arrow “A” below IF set to some other setting Customized alias name See arrow “B” (as in Appendix below Converging Systems Inc. Page 6 Rev.5.0.0...
Page 34
-Select the “+” mark in front of each Device to expand the data fields/. After you select the “+” mark the following expanded set of data fields becomes visible. Converging Systems Inc. Page 7 Rev.5.0.0...
Page 35
In order to invoke bi-directional communication for the ability for the control system’s dimmer sliders to automatically respond to changes in motor position states (a really cool feature), set the NOTIFY Flag to either ENABLE Converging Systems Inc. Page 8 Rev.5.0.0...
Page 36
-Select File/Save Map File and name appropriately. DV-5 Save variable so that they can retrieved/reused in the future Note: To “reinstall” saved Map file, simply Select Load Project, and navigate to file that was previously stored. Converging Systems Inc. Page 9 Rev.5.0.0...
Page 37
Converging Systems Inc. Page 10 Rev.5.0.0...
Page 38
Note: motor voltage must match AC mains input. Compliance ETL Listing to UL 325, FCCA, CE, RoHS Dimensions 5.9” (15cm) x 3.93” (10cm) x 3.54”(9 cm) Weight Manufacturing Origin Designed and Manufactured in the United States Converging Systems Inc. Page 11 Rev.5.0.0...