Setting Dip Switch - Citizen CT-S300 User Manual

Citizen systems line thermal printer user's manual ct-s300
Hide thumbs Also See for Citizen CT-S300:
Table of Contents

Advertisement

3.6 Setting DIP Switch

The DIP switch is present on the serial interface.
Remove the board fixing screws, take out the interface board, and then set the
DIP switch.
The function of each switch is as shown below.
Switch No.
Function
1
Communication condition DIP switch setting
setting method
2
Hand shake
3
Bit length
4
Parity check
5
Parity selection
6
Baud rate selection
7
8
INIT
Selecting baud rate
Baud Rate (bps)
2400
4800
9600
19200
38400 bps can also be selected by a command, etc.
DIP switch
ON
XON/XOFF
7 bits
With parity
Even parity
See Table below.
Reset
Switch No.
6
OFF
ON
OFF
ON
— 19 —
OFF
Memory switch
setting
DTR/DSR
8 bits
None
Odd parity
Invalid
7
OFF
OFF
ON
ON
Initial
Settings
ON
OFF
OFF
OFF
OFF
ON
ON
OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents