Page 3
Page: 3 of 35 Foreword Thank you for purchasing a Siemens Energy Subsea product. The information contained in this document is an overview including the protection, storage, shipment, unpacking, deployment and generation ‘TC3A’ DigiTRON Retrievable Electrical Distribution Unit (REDU) and maintenance for 1 mounting plate.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 6 of 35 PRODUCTS COVERED BY THIS MANUAL This document is an overview of the protection, storage, shipment, unpacking, deployment, and generation ‘TC3A’-type Retrievable Electrical Distribution Unit maintenance instructions for the 1 (REDU).
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 7 of 35 BASIC INFORMATION & QUICK REFERENCE Product overview DigiTRON REDUs intended use is communication and distribution of low voltage between pieces of electrical equipment that are submerged in water, e.g. subsea. The REDUs utilizes DigiTRON connectors.
Any information, records, or Health and Safety feedback that needs to be detailed can be recorded in section 10 of this document and sent to the relevant department in Table 3. Product advice label The following product advice label is supplied with all Siemens Energy subsea products. Figure 1 Product advice label...
9 of 35 Product marking Siemens Energy REDU products are marked with the Siemens Energy part number and unique serial number. Also, the voltage, temperature and water depth ratings are indicated. Typically these are etched on a yellow-coloured label permanently attached to the product (refer to...
11 of 35 PRODUCT SAFETY Siemens Energy Subsea recommends that the termination of all equipment shall only be undertaken by trained, suitably qualified and experienced personnel (SQEP) i.e. competent person. Following installation, commissioning or deployment of product, if you have any feedback please complete and return the Customer Comments/Feedback form (Section 10).
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 12 of 35 General safety information Installation by competent persons only The installation, inspection, maintenance and repair of the product shall be undertaken by trained, suitably qualified and experienced personnel (SQEP) i.e. competent person, to carry out a specified activity.
Page 13
The REDUs are non-serviceable by the user. In case of suspected faults with the product (refer to section 8.2), do not use the product and contact Siemens Energy Technical Support or Siemens Energy Product Safety for advice. Never attempt to carry out maintenance work or repairs on the product yourself.
Page 14
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 14 of 35 Warning. Risk of minor personal injury from high temperature of the product due to ohmic heating in short-circuit condition or high over-currents. In the event of a high over-current, allow the connectors to cool before touching. Ensure all testing of products both factory and deployed in-field have been completed by competent persons.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 15 of 35 Warning. Risk of bodily injury from heavy product falling during lift with machinery. Ensure machinery/slings used have been tested and are within their expiry date. Safe lifting guidelines must be followed, e.g. lifting plan, banksman, etc. Correct lifting points must be identified and used.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 16 of 35 ABBREVIATIONS °C Degree Celsius °F Degree Fahrenheit Ampere Alternating Current American Petroleum Institute Community European COSHH Control of substances hazardous to health Cathodic Protection Direct Current Drawing Electrical Distribution Unit Electrical Flying Leads Electrical Magnetic Field Metres...
Plug connectors do not require full dummy connectors for protection. Siemens Energy Subsea advise the fitting of subsea caps to protect plugs against marine growth. It is good practice to always fit the protective cap when a connector is unmated topside prior to deployment to provide mechanical protection.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 18 of 35 PREPARING PRODUCT FOR USE OR STORAGE Product protection and packaging The REDU is designed to withstand vibration that occurs during transportation. The REDU is manufactured primarily from 316L stainless steel (UNS S31603), and as such is designed to withstand harsh environments.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 19 of 35 Unpacking Remove wrapping material taking care to inspect for any surface damage or items that may have become separated from the product. For parts supplied individually and wrapped in materials, do not use a knife to cut the wrapping material, as this may cause damage to any elastomeric parts or painting of the product.
Page 20
Repackaging to prevent damage in transport In the event of a requirement to return the REDU back to Siemens Energy, the REDU should be transported back in its designated transportation Box. Transport or topside protective cap should be fitted to the connector(s) and care should be taken to protect the connector(s) with bubble wrap or similar wrapping materials to avoid any surface damage.
Issue Date: 16/11/2020 Revision: Page: 21 of 35 INSTALLATION AND ASSEMBLY If in doubt contact Siemens Energy Technical Support connectortechnicalsupport.gb@siemens- energy.com for more detailed information. Cathodic protection The REDU and base plate assembly has been manufactured primarily from 316L stainless steel (UNS S31603) and must be connected to the host structures CP (Cathodic Protection) system at all times using the leads provided.
Caution. Risk of material damage. Test connectors should never be used in water. There is a high change of damage to the test connector and also to the connector under test. Below are some images of standard Siemens Energy Subsea test connectors. Figure 5...
Only a Suitably Qualified and Experienced Person (SQEP) should install the cable tails, e.g. person trained by Siemens Energy. Siemens Energy installation procedure should be used. Figure 6 Example of standard subsea connector (shown untailed) Base plate installation The standard base plate is supplied with 6-off M10 x 40mm socket head cap screws.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 24 of 35 Values – refer to Figure 8 to Figure 10 Misalignment type Horizontal 20° above the horizontal plane End View +/- 20° from the vertical plane Plan View +/- 2.5° from the centre line of the mounting plate +/- 36mm (1.42”) radius of the centre of the primary location pin Cone to Pin Concentric Table 5...
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 25 of 35 Figure 8 a) Allowable Horizontal Misalignment, b) End View Allowable Misalignment NOTE: Dummy Plug and Earthing Receptacle not shown in Figure 8- Figure 10 Caution. Risk of material damage. If the REDU Box is angled below the horizontal plane when attempting to locate the second location pin, damage to the Earthing Receptacle/Dummy Plug may occur.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 26 of 35 Figure 9 Secondary Pin Capture Misalignment Maximum cone to pin misalignment: Figure 10 shows that location cone 1 has an allowable vertical misalignment of +/-36mm (1.42”) maximum around the vertical axis of the primary location pin. The 43mm (1.7”) space between the secondary alignment cone and pin must be utilised at this point.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 27 of 35 Figure 10 Allowable Cone to Pin Concentric Misalignment When the unit is fully mated to the base plate, there is an option to use a locking rod to secure the unit to the base plate via a 23mm (0.905”) diameter through hole on the guideposts (see Figure 11) See Note Below.
The product should be silent during operation and its appearance should not change. Normal and faulty/dangerous operation Do not operate the product if there appears to be a fault. If in doubt contact Siemens Energy Technical Support. Below are some indications of a product fault.
There are no user serviceable parts in the REDUs. Disassembly of the product should not be attempted. If there are any problems developed with the product then the user should contact Siemens Energy Technical Support for advice. Subsea protection of receptacle contact pins Caution.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 30 of 35 Figure 12 ROV-type Transport Caps (left) and Topside Protective Caps Caution. Risk of material damage. If storage is carried out in saline conditions, e.g. on a ship’s deck or hold, then a Subsea Environment Cap or Dummy Plug connector should be used to protect the receptacle pins from corrosion.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 31 of 35 Note that there is clear subsea visible differentiation between the Environment Cap, and Dummy with open circuit, looped with wire or resistors. Labels are added for this purpose (not shown on these images).
Inspect the receptacle pins for any signs of damage, such as bent pins, blackening due to electrical faults, or corrosion of the pins (green colour) or others in section 8.2. If evidence of such faults exists, do not use the connector. Please contact Siemens Energy Technical Support for advice.
If connectors can’t be mated both the plug and receptacle need to be inspected for any mis- alignment damage or debris that is preventing connection. • If any damage has occurred, please contact Siemens Energy Technical Support for advice. ROV connector maximum misalignment values and mating forces Refer to section 5.1...
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 34 of 35 ROV connector post-mating checks During mating the orange indicator lip seal located on the plug connector will fold back and disappear into the alignment cone on the receptacle connector. After a successful mating of the connectors no part of the indicator lip seal should protrude through the joint between the plug and receptacle connector.
Document No: IOM-006 Issue Date: 16/11/2020 Revision: Page: 35 of 35 CUSTOMER COMMENTS/FEEDBACK Please complete the Sign Off section at the bottom of form to confirm each page of this document has been read and complied with in full. Originator Name and Initials (BLOCK CAPITALS) Date ...
Need help?
Do you have a question about the DigiTRON Retrievable Electrical Distribution Unit and is the answer not in the manual?
Questions and answers